Laserfiche WebLink
SYSTEM SETUP <br />.JAN 6. 2009 3:55 PI°1 <br />SYSTEM UNITS <br />U.S. <br />SYSTEM LANGUAGE <br />ENGLISH <br />SYSTEM DATE,,TIl'IE FORMAT <br />MON DD YYYY HH:MM:SS xM <br />152993 SAFEWAY INC. <br />1804 W. 11TH ST. <br />TRACY.CA <br />x:06110577605001 <br />SHIFT TIME 1 6:00 AM <br />SHIFT TIME 2 12:00 AM <br />SHIFT TIME 3 : DISABLED <br />SHIFT TIME 4 DISABLED <br />SHIFT BIR PRINTOUTS <br />DISABLED <br />DAILY BIR PRINTOUTS <br />DISABLED <br />TICKETED DELIVERY <br />DISABLED <br />TANK, FIER TST NEEDED WRN <br />DISABLED <br />TANK ANN TST NEEDED WRN <br />DISABLED <br />LINE RE -ENABLE METHOD <br />PASS LINE TEST <br />LINE PER TST NEEDED WRN <br />DISABLED <br />LINE ANN TST NEEDED WRN <br />DISABLED <br />PRINT TC VOLUMES <br />ENABLED <br />TEMP COMPENSATION <br />VALUE (DEG F ): 60.0 <br />STICK HEIGHT OFFSET <br />DISABLED <br />ULLAGE : 9044 <br />H -PROTOCOL DATA FORMAT <br />HEIGHT <br />PRECISION TEST DURATION <br />HOURS: 60 <br />0.20 GPH LINE TEST <br />AUTO -CONFIRM: ENABLED <br />0.10 GPH LINE TEST <br />AUTO -CONFIRM: ENABLED <br />PRINT PRECISION LINE <br />TEST RESULTS: DISABLED <br />DAYLIGHT SAVING TIME <br />ENABLED <br />START DATE <br />MAR WEEK 3 SUN <br />START TIME <br />2:05 AM <br />END DATE <br />NOV WEEK 1 SUN <br />END TIME <br />2:00 AM <br />RE -DIRECT LOCAL PRINTOUT <br />DISABLED <br />EURO PROTOCOL PREFIX <br />S <br />SYSTEM SECURITY <br />CODE : 000000 <br />MAINTENANCE HISTORY <br />DISABLED <br />TANK, CHART SECURITY <br />DISABLED <br />CUSTOM ALARMS <br />DISABLED <br />MASS!DENSITY <br />DISABLED <br />C:OMMUN I CTAT I GIGS SETUP <br />PORT SETTINGS: <br />COMM BOARD : I (ED IM ) <br />RS -232 SECURITY <br />CODE : DISABLED <br />COMM BOARD 2 (RS -232) <br />BAUD RATE 2400 <br />PARITY ODD <br />STOP BIT 1 STOP <br />DATA LENGTH: 7 DATA <br />RS -232 SECURITY <br />CODE : DISABLED <br />COMM BOARD 3 (S -SAT <br />BAUD RATE 9600 <br />PARITY NONE <br />STOP BIT 1 STOP <br />DATA LENGTH: 8 DATA <br />RS -232 SECURITY <br />CODE : DISABLED <br />DTR NORMAL STATE: HIGH <br />COMM BOARD 5 (RS -485) <br />BAUD RATE 2400 <br />PARITY EVEN <br />STOP BIT 1 STOP <br />DATA LENGTH: 7 DATA <br />RS -232 SECURITY <br />CODE : DISABLED <br />COM11 BOARD 6 (RS -232) <br />BAUD RATE 1200 <br />PARITY ODD <br />STOP BIT 1 STOP <br />DATA LENGTH: 7 DATA <br />RS -232 SECURITY <br />CODE : DISABLED <br />AUTO TRANSMIT SETTINGS: <br />AUTO LEAF: ALARM LIMIT <br />DISABLED <br />AUTO HIGH WATER LIMIT <br />DISABLED <br />AUTO OVERFILL LIMIT <br />DISABLED <br />AUTO LOW PRODUCT <br />DISABLED <br />AUTO THEFT LIMIT <br />DISABLED <br />AUTO DELIVERY START <br />DISABLED <br />AUTO DELIVER`! END <br />DISABLED <br />AUTO EXTERNAL INPUT ON <br />DISABLED <br />AUTO EXTERNAL INPUT OFF <br />DISABLED <br />AUTO SENSOR FUEL ALARM <br />DISABLED <br />AUTO SENSOR WATER ALARM <br />DISABLED <br />AUTO SENSOR OUT ALARM <br />DISABLED <br />