Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sugov.or4/ehd/unitiii.html <br /> CONTINUATION FORM Page: 3 of 3 <br /> OFFICIAL INSPECTION REPORT Date: 06/02/11 <br /> Facility Address: Safeway #2600 1987 West 11th Street, Tracy Program: UST <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> UST Inspection: Routine and Annual Monitoring System Certification testing <br /> 4. Financial responsibility documents have not been submitted to the EHD. Last Certification of Financial <br /> Responsibility document signed on 08/2009. Insurer Indian Harbor Insurance Company policy for UST <br /> coverage period for 07/2007 - 07/2010. Current financial responsibility documents are required to be <br /> submitted annually. Complete and submit a copy of the financial responsibility. <br /> 5. The Monitoring Plan on site are not current and not approved by the EHD. An incorrect sensor model <br /> for the annular space was listed. An 91/diesel annular sensor was changed under permit on 06/11/07 <br /> from a VR 420 to a VR 460 but the Monitoring Plan was not updated to include this change. In addition, <br /> all Monitoring System Certification test results from 2008 to present has yet to reflect the change in <br /> sensor model. The Monitoring Plan must be current and approved by the EHD. Complete and submit a <br /> copy of the Monitoring Plan for approval by the EHD. An approved copy will be returned for your <br /> records. <br /> 10 & 12. The 87 annular sensor was found not to be resting at the bottom of the annular space bottom <br /> when tested and, therefore, the tank is not monitored. The depth of the annular was measured to be 188 <br /> inches and was found to be ten inches too short. The interstitial space shall be monitored with a <br /> monitoring system connected to an audible and visual alarm system. The VR 420 sensor was replaced <br /> with a VR 460 sensor serial number#741249 and retested during the inspection. Obtain a permit from <br /> the EHD for this work within one business day. If a permit is not obtained within one business day, a <br /> "Failure to Obtain a Permit" penalty will apply. <br /> 23d. The Designated Operator (DO) failed to verify that all employees have received annual refresher <br /> training every 12 months. Maria L. and William K. were both last trained on 03/10/10. Maria recently had <br /> her annual refresher training on 04/19/11. William has yet to receive training as of today. Ensure the DO <br /> trains employees every twelve months. <br /> Submit to SJC EHD within 30 days (07/04/11): <br /> 1. one copy of the completed "Return to Compliance Certification" form <br /> 2. a written corrective action statement for the above violations <br /> 3. requested/ supporting documentation <br /> Notes: <br /> - Next tri-annual secondary containment testing due 12/2011. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE($122). <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT Ayy TIME OT EHD'S CURRENT HOURLY RATE. <br /> EHD In a or. Received By- Title: <br /> EHD 23-02-003 Rev 08/10/10 CONTINUATION FORM <br />