My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHRISMAN
>
25600
>
2800 - Aboveground Petroleum Storage Program
>
PR0522654
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/19/2019 4:31:03 PM
Creation date
2/28/2019 4:41:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0522654
PE
2832
FACILITY_ID
FA0010314
FACILITY_NAME
DLA Distribution Center San Joaquin
STREET_NUMBER
25600
Direction
S
STREET_NAME
CHRISMAN
STREET_TYPE
Rd
City
Tracy
Zip
95304
CURRENT_STATUS
01
SITE_LOCATION
25600 S Chrisman Rd
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ O 1` Q U I `IA,II, Environmental Health Department <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> DLA Distribution Center San Joaquin 25600 S Chrisman Rd,Tracy January 24, 2019 <br /> Other Violations <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> 4050 See below Unlisted Abandonment/lIlegal Disposal/Unauthorized Treatment violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 203 CFR 112.3 Failure to implement the SPCC Plan. <br /> The SPCC plan calls for spill kit to be located in the mobile refueler. The mobile refueler was observed a spill pad <br /> and some spill booms. This would not be sufficient to address potential spill containment mentioned in the plan and <br /> for which the mobile refueler spill kit is referenced. The SPCC plan calls out locations of spill kits throughout the <br /> facility,According to facility personnel there are no spill kits.The owner or operator or an onshore or offshore facility <br /> subject to this section must prepare in writing and implement a Spill Prevention Control and Countermeasure Plan <br /> (hereafter"SPCC Plan"or"Plan")," in accordance with§ 112.7 and any other applicable section of this part. <br /> Implement the SPCC plan as written. <br /> This is a minor violation. <br /> 619 CFR 112.7(f)(1) Failed to train personnel on all discharge prevention details listed in this section. <br /> Oil handling personnel were not trained. The personnel responsible for the operation of the mobile refueler had not <br /> been trained, according to a discussion between facility personnel and personnel of mobile refueler. At a minimum, <br /> oil handling personnel shall be trained in the operation and maintenance of equipment to prevent discharges; <br /> discharge procedure protocols; applicable pollution control laws, rules, and regulations;general facility operations; <br /> and the contents of the Spill Prevention, Control, and Countermeasure Plan. Immediately provide this training to all <br /> oil handling personnel and submit a copy of the training log to the EHD. <br /> This is a Class II violation. <br /> 717 CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas. <br /> A dispenser on the 12,000 gallon diesel tank was observed to have a small leak from piping or the hose. Visible <br /> discharges which result in a loss of oil from a container, including but not limited to seams, gaskets, piping, pumps, <br /> valves, rivets, and bolts, must be promptly corrected. Immediately fix leak, and manage according to the California <br /> Code of Regulations Title 22 hazardous waste regulations. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by February 23, 2019. <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an <br /> appointment, please call (209)468-3420. <br /> FA0010314 PR0522654 SCO01 01/24/2019 <br /> EHD 28-01 Rev.09/27/2018 Page 4 of 5 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.