San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Safewa Fuel Center #2600 <br />Facility Address: <br />1987 W ELEVENTH ST, TRACY <br />Date: <br />June 20, 2017 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />209 <br />CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to document all the alarms from the attached alarm history on the designated <br />operator monthly inspection report and failed to check that they were responded to appropriately. The missing <br />alarms include: T3 (diesel probe) 5/1/17 overfill alarm. During the monthly inspection, the designated operator shall <br />review the alarm history for the previous month, check that each alarm was documented and responded to <br />appropriately, and attach a copy of the alarm history with documentation taken in response to any alarms to the <br />monthly report. Ensure that designated operators performing monthly inspections at this facility are including all of <br />the required information on the reports. <br />This is a minor violation. <br />211 <br />CCR 2715(f) Designated operator employee training not performed or log not kept. <br />The designated operator employee training for Will Kaufman was not current. Mr. Kaufman's training was last <br />conducted on 4/14/16. The April and May 2017 designated operator inspection reports noted that Mr. Kaufman <br />needed current training. For a portion of the inspection, Mr. Kaufman was the only employee on site. The <br />designated operator shall train facility employees for which he or she is responsible in the proper operation and <br />maintenance of the UST system once every 12 months. The training shall include, but is not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Ensure that employees have been trained by the designated operator. The training for Mr. Kaufman was conducted <br />by the designated operator at the time of inspection. <br />This was corrected on site. <br />This is a minor violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by July 20, 2017. <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />Documents reviewed: CERS submittals, alarm history, monthly designated operator inspection reports, designate( <br />operator training log, site alarm logs, maintenance records, test records <br />Documents provided: Return to Compliance Certification form <br />Page 4 of 5 <br />