UNDER -DISPENSER CONTAINMENT (UDC) TESTING <br />Test Method Developed By: ❑ UDC Manufacturer M Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum V1 Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: ]neon sump Tester Equipment Resolution: +/_ 0.002 Inches <br />�- <br />UDC # 9/10 <br />UDC # 11/12 <br />UDC # 13/14 <br />UDC # 15/16 <br />UDC Manufacturer: <br />Western Fiberglass <br />Western Fiberglass <br />Western Fiberglass <br />Western Fiberglass <br />UDC Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />UDC Depth: <br />31" <br />31" <br />31" <br />31" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />5" <br />5" <br />5" <br />5" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />10" <br />10" <br />10" <br />10" <br />Condition of UDC prior to <br />testing: <br />Good <br />Good <br />Good <br />Good <br />Portion of UDC Tested <br />2" Above Piping <br />2" Above Piping <br />2" Above Piping <br />2" Above Piping <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?. <br />N/A <br />N/A <br />N/A <br />N/A <br />Turbine shutdown response time <br />N/AN/A <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail- <br />safe shutdown?' <br />E] Yes ❑ No m NA <br />E] Yes ❑ No p NA <br />C] Yes ❑ No ® NA <br />❑ Yes El No m NA <br />Was fail-safe verified to be <br />operational?* <br />❑ Yes ❑ No 0 NA <br />❑ Yes ❑ No 0 NA <br />❑ Yes ❑ No El NA <br />❑ Yes ❑ No Z NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />30 Minutes <br />30 Minutes <br />30 Minutes <br />30 Minutes <br />Test Start Time: <br />Initial Readin (Rt): <br />Inches <br />Inches <br />Inches <br />Inches <br />Test End Time: <br />Final Reading RF): <br />Inches <br />Inches <br />Inches <br />Inches <br />Test Duration: <br />Change in Reading RF -Rt): <br />Pass/Fail Threshold or Criteria: <br />0.002 <br />0.002 <br />0.002 <br />0.002 <br />Test Result: <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />UDC 9/10,11/12, 13/14, 15/16 Visually failed due to jumper lines. <br />"Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment <br />testing scope of work". <br />REC w r <br />OrT <. NO <br />ENVIRONMENTAL HEALTH <br />PERMIT/SERV!^FS <br />