Laserfiche WebLink
i <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.sigov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> FacilitName: Safeway Fuel Center#2600 Address: 1804 West 11th Street, Tracy ate: Jun 12, 2013 <br /> Facility Title: <br /> Contact: Rob Singh Enviro Cdr =469-7164 <br /> Inspection <br /> Type: X Routine QMonitoring System Certification 11 Installation ii Complaint-ID#: E]Other: <br /> (Authority HSG 25289) ( <br /> Consentfor: Xlnspection XSampling XPhotos Granted by: i[I (/("A Title: 6M <br /> MonitoringVdRoot TLS-350 Piping overfill <br /> Panel: <br /> eeer- - <br /> System: XPressurized ❑Suction ❑Gravity prevention: D Mechanical XAudible/visual <br /> usr1 2 - 3 <br /> - - - - - - - - - - - - - - - - - - 91-octane - - - - - - - .89-eeMtie' ----------------------------- <br /> - - - - - - - - <br /> Product87-octaneDesignated ICC Exp. r Violations: ❑M1-Release Detection M2-Release Prevention M3-Both <br /> Operator: t Date: 0S H� <br /> On Site Servic ICC Exp. Manufacturer's�( <br /> Technician: S Date: Training: V 0 <br /> VIOLATIONS <br /> # I Cl I C2 M Code Section HSC=California Health and Safety Code;CCR=California Code of Regulations <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> File Review <br /> 101 HSC 25284 No permit to operate <br /> 102 HSC 25404.5 Annual operating fees not paid <br /> 103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br /> monitor the tanks stem <br /> 104 HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department(EHD) <br /> 105 CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 106 CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br /> 108 CCR 2637 Secondary containment:(a)test not performed;(e)test report not submitte witi 30 days;(f)test notification <br /> not provided to the EHD at least 48 hours prior to conducting the test <br /> Il <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 days; <br /> 109 CCR 2638 (e)test notification not provided to the EHD pt le st 48 hours prior to conducting an installation,repair, <br /> replacement,calibration,or certification <br /> 110 HSC 25291(f) Annual line leak detector test not performed (M7) <br /> 111 HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (M1) <br /> 113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> 115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br /> permit conditions <br /> 116 HSC 25292.5 Enhanced leak detection(ELD)testing not performed on a system located within 1000'of public well,or <br /> failures not repaired and retested <br /> 117 CCR 2661 Permit to repair UST system not obtained <br /> 118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 119 HSC 25298(b) Permit to temporarily close UST system not obtained <br /> 120 HSC 25298(c) Permit to close UST system not obtained <br /> On Site Records <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6'/2 years,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 201 CCR 2712(b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; <br /> (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring <br /> equipment, round water elevations,or other test results; 6 results of inventory readings and reconciliations <br /> 202 CCR 2712(i) Monitoring plan,response plan,and/or operating permit and all conditions not onsite <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight hours (M1) <br /> 203 CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned up after eight hours,or a sudden loss of <br /> product was not reported to the EHD within 24 hours <br /> Inspector: Rec ' By Title <br /> Thuy Tran (209) 468-8257 ��"/ 4,.,Ia I <br /> EHD 23-02 Rev 04/19/12 Page 1 UST INSPECTION REPORT <br />