My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO 2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
2/28/2019 4:45:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
347
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CEIVED <br /> 1 <br /> Monitoring Y Equipment System E ui ment Certification <br /> For Use By All Jurisdictions iflithin The State oj'California DEC 12 2014 <br /> Authority Cited:Chapter 6.7, Health and Safety Code;Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certific ffi&rt must be �EA�TH <br /> prepared for each monitoring system control panel by the technician who performs the work. A copy of this formEOust be provided <br /> to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST system <br /> within 30 days of test date. <br /> A, General information <br /> Facility Name:Safeway Bldg. No.: <br /> Site Address: 1987 W. 11th St, City: Tracy,CA Zip: 95376- <br /> Facility Contact Person: Will Contact Phone No.: (209)830-2950 <br /> Make/Model of Monitoring System: VR TLS-350 Date of Testing/Servicing: 11/13/14 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/sen iced: <br /> Tank ID: Tank ID: <br /> ❑ In-Tank Gauging Probe. Model: ❑ In-Tank Gauging Probe. Model <br /> ❑ Annular Space or Vault Sensor. Model: ❑ Annular Space or Vault Sensor. Model <br /> ❑ Piping Sump\Trench Sensor(s). Model: ❑ Piping Sump\Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line teak Detector. Model. <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill\High-Level Sensor. Model: ❑ Tank Overfill\High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2) ❑ Other(specify equipment type and model in Section E on Page 2) <br /> Tank IQ Tank W: <br /> ❑ In-Tank Gauging Probe. Model: ❑ In-Tank Gauging Probe. Model: <br /> ❑ Annular Space or Vault Sensor. Model: ❑ Annular Space or Vault Sensor. Model: <br /> ❑ Piping Sump\Trench Sensor(s). Model: ❑ Piping Sump\Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model. <br /> 0 Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model <br /> ❑ 'rank Overfill\High-Level Sensor. Model: ❑ Tank Overfill\High-Level Sensor. Model. <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2) <br /> Dispenser IDs 13-14 Dispenser ID• 15-16 <br /> ❑ Dispenser Containment Sensor(s). Model: VR 794380-208 ❑ Dispenser Containment Sensor(s). Model. VR 7WBO-208 <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser IQ: 17`18 Dispenser IIS• 19-20 <br /> ❑ Dispenser Containment Sensor(s). Model: VR 794380-208 ❑ Dispenser Containment Sensor(s). Model vie 794380.203 <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s) <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> *Ifthe facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility <br /> C. Certification- I certify that the equipment Identified in this document was inspected/serviced in accordance with the <br /> manufacturer's guidelines. Attached to this Certification is information(e.g.manufactures'checklists)necessary to verify that this <br /> information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br /> reports,I have also attached a copy of the; (check all that app(v): ® System set-up ® Alann history report <br /> Technician Name(print):Kris Bell Signature: <br /> Mfg.Cert.#.: B33709 ICC# 5297793-UT License.No.: 485184 <br /> Testing Company Name: Service Station Systems Phone No.: (408) 971-2445 <br /> Testing Company Address: 680 Quinn Ave., San Jose,CA 95112 Date of Testing/Servicing: 11/13/14 <br />
The URL can be used to link to this page
Your browser does not support the video tag.