My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO 2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
2/28/2019 4:45:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
347
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20'13-06-13 04:01 2600 2098302954 >> P 2/8 <br /> i <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-8232 <br /> Telephone:(209)468-3420 Fax:(209)488-3433 Web:WffW.SdCI0y.OFq/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> radio Fattility <br /> Nsrml Safeway Fuel Center#2600 1804 West 11 th Street, Tracy inspection Jun 12, 2013 <br /> r Address: Ogle <br /> VIOLATIONS <br /> # C1 C2 M Code socil l HSC=CA Hegy and Code:CFR—=Co*or' 1 11, l ulsllgl� I <br /> C 1=Class 7 <br /> vidlpn C2- w;dA00r wipulon <br /> ,7 IjI[1thh,p�„�! �'}4• 7h.�) rti^^'1 sr�,+t +( .r ,3{y!, Yry <br /> 70Z 7 <br /> CCR 2643 �;^. r.."a l+'�,64rlLrra��,.�Of'v'§�tiY(ea'Afwt�4�^IL�JfIiPt' ^ .4,..».rE1 Y�i�krY�•JffLAr 1!'I�'I.. <br /> (e BlenNdl tightnm test of ravity pl irlg not peftrmod(pre•.January 1,1984) <br /> I 70"s 643 d)! Triennial line lest for conventionalon rn n (Mi <br /> CCR Z sudi <br /> Qt norm <br /> g ed(pre-January 1,1884) <br /> 998 ;7-- K,a•a ;/o{aflofrig>;: .rY.,,•rF� ✓ <br /> Other .s:k••, t.1 ,<�'..,�%T,�'f m?dlf(=::Y ' ..•.. . <br /> attadled"Continuation—Official Insperlton Report"for violationis)not III above. <br /> j SUMMARY OF VIOLATIONS <br /> ACLASS 1,CLASS 11,or MINOR-Notice to Comply _ <br /> UST Inspection: Routin & Annual Monitoring System Certification <br /> Minor/ Notice to Comply violation #204 <br /> 204. The designated operator failed to check and note the correct test dates for the annual monitoring <br /> system certification. line leak detector and spill bucket testing on the designated operator monthly <br /> inspection reports from August 2012 to December 2012, five monthly reports. Designated operator had <br /> documented the incorrect date of 06/01/12 rather than the correct date of 06/05/12 which was corrected <br /> in the monthly reports from January 2013 to present. During the monthly inspection, the designated <br /> operator shall check that all required testing and maintenance for the UST system have been completed <br /> and document the dates they were done. Ensure that designated operators performing monthly <br /> inspections at this facility are including ali of the required information on the reports. Submit a written <br /> statement how to ensure reports will have correct dates. <br /> Submit to SJC EHD within 30 days (07/12/13): <br /> I. one copy of the completed "Return to Compliance Certification" form <br /> 1 2. a written corrective action statement ensure reports will have correct test dates <br /> Nates: <br /> -CERS: Underground Storage Tanks: lists incorrect secondary product piping construction. <br /> Monitoring Plan in Section X. Comments info: lack info on overfill prevention method <br /> Please contact me for more information <br /> i <br /> i <br /> i <br /> i <br /> i <br /> i <br /> i <br /> i <br /> I, <br /> P <br /> ALL END STAFF TIME A&%MiAlEO vdlTH FAILING TO COMPLY BY THE ABOVE NOTCD DATES WILL BE gfI IF AT THE CURRENT HOURLY HATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> m3pedo� KerM Q gy: <br /> EHO 23-02 Rev 04/19112 <br /> PagC 9 UST INSPECTION REPORT <br /> I i, <br />
The URL can be used to link to this page
Your browser does not support the video tag.