My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 2002
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
INSTALL 2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:48 AM
Creation date
2/28/2019 5:01:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2002
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
169
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Modern Welding Company, Inc. <br /> modern PO Box 1450 - Owensboro, KY - 42302 <br /> Subsidiaries Nationwide - (502)085-4400 <br /> LONG FORM: Section 13215 <br /> Guide Specification GLASTEEL HModern Welding Company, Inc <br /> GLASTEEL II, GS-13, FRP Jacketed Steel <br /> Underground Storage Tank <br /> PART lI Products <br /> PA.P,T I General 2.01 GLASTEEL II Underground Storage Tanks <br /> 1.01 Related Work Specified in Other Sections A. Loading Conditions: Tanks shall meet the <br /> following design criteria. <br /> A Cast-in-Place Concrete: Section 03300 1. Surface Loading: When installed according to <br /> B. Anchor Bolts: Section 05501 manufacturer's installation instructions, tanks <br /> C. Plastic Pipe: Section 15064 shall withstand surface H-20 axle loads <br /> D. Liquid Level Gauges: Section 15174 (32,000 lbs/axle): <br /> 2. Internal Load: Primary tank shall withstand <br /> 1.02 duality Assurance an air pressure test of 3-5 psi. Secondary tank <br /> shall be vacuum tested. <br /> A. Acceptable Manufacturer: Modern Welding WARNING: Follow manufacturer's testing <br /> Company, Inc. instructions to avoid damage <br /> to the secondary tank. Do not <br /> B. Governing Standards apply positive pressure. <br /> 1. U.L. 58, Underwriters Laboratories, Inc., Steel <br /> Underground Tanks for Flammable and 3. Tanks shall be designed to support accessory <br /> Combustible Liquids. equipment such as ladders, submerged pumps, <br /> 2. U.L. 1746, Underwriters Laboratories, Inc., containment sumps, etc. when installed <br /> Corrosion Protection Systems for Underground according to manufacturer's instructions and <br /> Storage Tanks. limitations. <br /> 3. NFPA 30 and 30A, National Fire Protection 4. Tanks shall be designed in such a manner to <br /> Association Flammable and Combustible Code. provide for monitoring of the interstice. <br /> 4. Uniform Fire Code, International Fire Code 5. Primary tank shall be designed per Under- <br /> Institute. writers Laboratories, Inc. #58, Table 3.1. <br /> 5. B.O.C.A., National Fiore Prevention Code <br /> B. Produce Storage Requirements <br /> 1.03 Submittals 1. Tanks shall be capable of storing liquids with <br /> specific gravity up to 1.1. <br /> A. Shop Drawings: Contractor shall submit 2. Tanks are designed for operation at <br /> copies of shop drawings for each tank. Location atmospheric pressure only. All primary tanks <br /> of fittings and accessories with specific shall be vented. <br /> dimensions shall be shown on all drawings. 3. Tanks shall be capable of storing gasoline, <br /> gasohol,jet fuel, avgas, diesel fuel or methanol <br /> B. Catalog Data: Contractor shall submit at ambient underground temperature or used <br /> current copies of manufacturer's literature. for fuel oil at temperatures not to exceed 150 <br /> degrees Fahrenheit. <br /> C. Certification: Each tank shall bear the U.Z. 4. The interstice shall be monitored. <br /> listing mark for jacketed underground tank <br /> for flammable liquids storage. C. Dimensional Requirements <br /> 1. Nominal capacity of the tank shall be <br /> D. Installation Instructions: Contractor shall gallons. <br /> submit copies of manufacturer's current 2. Nominal outside diameter of the tank shall be <br /> installation instructions. inches. <br /> 3. Overall length of the tank shall be <br /> approximately feet, inches. <br />
The URL can be used to link to this page
Your browser does not support the video tag.