Laserfiche WebLink
VVESIFER-N FIBERGLASS, LNC. 1-800-68&3375 <br /> FMAll .N- L� <br /> © D SLS RISER& REDUCERS <br /> Summar-, <br /> The r filament wound sump iser and riser reducer shall be installed onto the underground storage Mani`and In <br /> accordance with the manufacturers installation instructions.The UST sump riser and riser reducer shall provide <br /> an oven Dlrnng termination and inspection service area that is non-pe.-meapie to hyarocarbons,compatible with <br /> all fuel biends, and will not hold a static electrical charge. °rhe sump system shall contain environmentally <br /> hazardous fluids that might leak from piping terminations,fittings and flex-noses contained within the sump, <br /> ..,quire no interzai back-fill or bracing and be self supportiag. :ne sump shallbe manufac^.Dred by ester <br /> `iberglass,Inc. <br /> SF54 =SDeCifkatiOnS <br /> 1.01 System Suitability <br /> The Tank Sump Riser Tube and Riser Reduce Assembiy shall: <br /> A P_nach to the UST man way,bung fitting or cantainmeat collar to Prevent the intrusion of ground <br /> wat_•r into the sump assembly. <br /> B. Be of sufficient size to allow ail piping termiruation's,fittings,emi==t, and flex-hoses to be <br /> contained within the Sump Assembly. <br /> C. Provide ample area to allow servicing and inspection of all piping te.--nination's,fittings, <br /> equipment,and flex-hoses within the Sump Assembly. <br /> D. Contain any release of environmental contaminates from the tank fittings and equipment contained <br /> within the Sump Assembly. <br /> Provide an interface to the access"street"man way system with sealed water tight or a ction"1117- <br /> lid"Tank Sump Riser Tube Reducer Assembly. <br /> F. Be available as a U L.Listed device L eqs=ireq. <br /> 1.2 Construction Specifications <br /> A. Meet or exceed United States National Bureau of Standards PS 15-69 for Custom Contact_Moided <br /> Reinforced-Polvest_:. Chemical-Resistant Process Equipment or U.L.Listing if applicable. <br /> B. 3e const±scted of materials that are not harmful to the environment <br /> C. 3e non-p=, cable to the hydrocarbons and not weakened by exposure to these materials. <br /> D. Be suitabie for petroleum products and biends inciudimg methanoi and eti vi alcohol mires. <br /> _. ::ave a thirty(30)year warranty against corrosion. <br /> 1.3 Release Monitoring System shall: <br /> A Allow foil visual and phvsicai accessjinspection of all piping reductions; fittings,hoses,and <br /> equipment <br /> $. Provide a monitor rc t for e,*=""ic monitoring and evac,iation of fluids. <br /> P`ping Penezations <br /> A. "?-ovide locations for the installations of fluid tight pipe and conduit penetration seals to be <br /> :installed acccrdinsz to manufacn�r's =stnicUcns. <br /> asp ff eaai�,word/�ecrsiao�a,d�jan99 <br />