Serial: D1 <br /> Model: DTO <br /> Shop Calibration Performed: Wed Dec 09 07:11:39 2015 <br /> Before Survey Verification Performed: Thu Sep 10 12:13:47 2015 <br /> After Survey Verification Performed: Thu Sep 10 12:07.43 2015 <br /> I, <br /> Shop Calibration <br /> Readings References Results <br /> Zero Cal Zero Cal Gain Offset <br /> Short 10.201 102.203 10.200 102.200 Ohm-m 1.000 -0.001 <br /> Long 10.201 102.202 10.200 102.200 Ohm-m 1.000 -17.000 <br /> IEE 79.040 5274.100 counts 0.087 5.772 A <br /> VSN 0.000 5104.980 counts 0.000 97.371 V <br /> VLN 151.520 1374.820 counts 2.890 26.223 V <br /> Before Survey Verification <br /> Readings References Results <br /> Zero Cal Zero Cal Gain Offset <br /> Short 0.000 86.349 91.938 86.358 Ohm-m -0.065 91.938 <br /> Long 1063.350 92.876 92.820 92.820 Ohm-m 0.543 42.382 <br /> IEE 76.760 5159.780 counts 0.084 5.647 A <br /> VSN 0.000 5005.700 counts 0.000 95.478 V <br /> VLN 229.260 1346.020 counts 4.373 25.674 V <br /> After Survey Verification <br /> Readings References Results <br /> Zero Cal Zero Cal Gain Offset <br /> Short 0.000 86.360 31.067 86.374 Ohm-m 0.640 31.067 <br /> Long 1073.720 92.854 92.840 92.840 Ohm-m 0.538 42.873 <br /> IEE 75.800 5174.060 counts 0.083 5.662 A <br /> VSN 0.000 5020.180 counts 0.000 95.754 V <br /> VLN 228.600 1349.420 counts 4.360 25.739 V <br /> After Survey Verification compared to Before Survey Calibration <br /> Zero Cal <br /> Before After Before After <br /> Short 91.938 31.067 Ohm-m 86.358 86.374 Ohm-m <br /> Long 619.860 620.670 Ohm-m 92.820 92.840 Ohm-m <br /> Gamma Ray Calibration Report <br /> Serial Number: D1 <br /> Tool Model: ELOG <br /> Performed: Thu Sep 10 12:51:48 2015 <br /> Calibrator Value: 162.0 GAPI <br /> Background Reading: 114.5 cps <br /> Calibrator Reading: 345.3 cps <br /> Sensitivity: 0.7020 GAPI/cps <br />