GENERAL ACCESSIBILITY NOTES r-- ----,
<br /> � PULLLL SIDEfDE i 25"(MAX)
<br /> II --------------
<br /> 1. DOOR HARDWARE: z I I 24" MIN CLR @ EXT DRS + PULL SIDE
<br /> 1.1. HAND ACTIVATED DOOR HARDWARE SHALL COMPLY WITH SECTIONS 11B-309.4&11B-404.2.7,CBC. OPERABLE PARTS OF HARDWARE I 18"MIN CLR @ INT DRS z 24 MINI 17"-25" FAUCET CONTROLS AND OPERATING
<br /> SHALL BE 34 IMIN)&44"(MAX)FROM THE FINISH FLOOR OR GROUND, OPERABLE HARDWARE PARTS SHALL BE OPERABLE W/ I + DOOR(SEE PLANT MECHANISMS SHALL BE OPERABLE WITH
<br /> ONE—HAND&SHALL NOT REQUIRE TIGHT—GRASPING,PINCHING,OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE + o r_________________ ONE HAND AND SHALL NOT REQUIRE TIGHT
<br /> OPERABLE PARTS SHALL NOT EXCEED 5 POUNDS. + .a I I , GRASPING,PINCHING OR TWISTING OF THE g
<br /> + I AT 1:2 SLOPE x w
<br /> 1.2. WHEN PROVIDED,THRESHOLDS SHALL BE 112"HIGH(MAX),PER SEC 1113-404.2.5,CBC, + I TYPICAL THRESHOLD i a WRIST.THE FORCE REQUIRED TO ACTIVATE H
<br /> 1.2.1. THRESHOLDS W/A CHANGE IN LEVEL OF 1/4"(MAX),SHALL BE PERMITTED TO BE VERTICAL&WITHOUT EDGE TREATMENT,PER 2 �T i m I CONTROLS SHALL BE NOT GREATER THAN
<br /> SEC 11B-303.2,CBCI + I 11 I x o i 516f. LEVER-OPERATED,PUSH-TYPE AND
<br /> 10
<br /> 1.2.2. THRESHOLDS W/A CHANGE IN LEVEL BETWEEN 1/4"(MIN)&1/2"(MAX)SHALL BE BEVELED W/A SLOPE NOT STEEPR THAN 1:2, z i i z i i FINISH FLOOR i Q „' i ELECTRONICALLY CONTROLLED
<br /> PER SEC 11B-303.3,CBC i I "' a I a MECHANISMS ARE EXAMPLES OF
<br /> te
<br /> 1.3. DOOR&GATE CLOSER'S SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90°,THE TIME REQ'D TO MOVE THE DOOR TO A i + 12"MIN I 24" MIN+ + ACCEPTABLE DESIGNS.SELF-CLOSING
<br /> POSITION OF 12 FROM THE LATCH IS(5)SECONDS(MIN),PER SEC 11B-404.2.8.1,CBC I + I VALVES ARE ALLOWED IF THE FAUCET
<br /> W/LATCH&CLOSER + I L---------
<br /> L PUSH SIDE___J L PUSH SIDE------� : a -- J REMAINS OPEN FOR AT LEAST 10 SECONDS
<br /> 2, DOORS:
<br /> (Y)=48"MIN IF DR HAS A CLOSER
<br /> 2.1. THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE SHALL COMPLY W/SEC 11B-404.2.9,CBC,AS FOLLOWS: 1RGNT NOTE: LINE TYPE {------) LATCH-8ID(s m
<br /> 2.1.1. INTERIOR HINGED DOORS&GATES: 5 POUNDS(MAX) REPRESENTS LEVEL MANEUVERING CLIARAhCA (PLAN)
<br /> 2.1.2. SLIDING OR FOLDING DOORS: 5 POUNDS(MAX) CLEARANCES AT DOORS PER SEC
<br /> 2.1.3. HINGED EXTERIOR DOORS: 5 POUNDS(MAX) 11B-404.2.4,CBC,AREA SHALL NOT TO
<br /> ----
<br /> 2.1.4. REQUIRED FIRE DOORS: 15 POUNDS(MIN ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY) i OUTSIDE
<br /> 2.2. SWINGING DOOR&GATE SURFACES WITHIN 10"OF THE FINISH FLOOR OR GROUND SURFACE SHALL HAVE A SMOOTH SURFACE ON THE ------------------------� EXCEED 2%SLOPE IN ANY DIRECTION& I I w
<br /> PU4LL SIDE I SHALL SLOPE AWAY FROM THE EXTERIOR I I PROVIDE INSUL PIPE WRAP
<br /> PUSH SIDE EXTENDING THE FULL WIDTH OF DOOR OR GATE. PARTS CREATING HORZ OR VERT JOINTS IN THIS SURFACE SHALL BE 36 I I I @ EXPOSED WATER
<br /> WITHIN 1/16"OF THE SAME PLANE AS THE OTHER&SHALL BE FREE OF SHARP OR ABRASIVE EDGES. CAVITIES CREATED BY ADDED MIN z OF THE BUILDING(TYP) I &WASTE PIPING PER SEC 118-604.5,1,CBC
<br /> KICK PLATES SHALL BE CAPPED, SEC 118-404.2.10,CBC
<br /> o i MAX COMPRESSED
<br /> UNISEX, MEN OR WOMEN H/C DOOR I
<br /> 3. OPERABLE PARTS: i I CARPET BELOW THRESHOLD
<br /> 3.1. OPERABLE PARTS SHALL COMPLY W/SEC11B-309,CBC I SIGN @ 60" HT , r
<br /> 3.2. A FORWARD OR PARALLEL CLEAR FLOOR SPACE OF 30"x48"(MIN)SHALL BE PROVIDED COMPLYING W/SEC 11B-305,CBC
<br /> FINISH FLOOR EVEN x I\V' z 5
<br /> 3.3. OPERABLE PARTS HEIGHT SHALL BE PLACED WITHIN THE REACH RANGES OUTLINED IN SEC 11B-305 CBC I I + a z z
<br /> ' 22"'MIN I z UNISEX,MEN OR WOMEN H/C BRAILLE I I z a, ao ao
<br /> 3.4. OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING,PINCHING,OR TWISTING OF THELij
<br /> I —
<br /> WRIST.THE FORCE REQUIRED TO ACTIVATE SHALL BE 5 POUNDS(MAX),PER SEC 1113309.4,CBC i SIGN @ 60"HT
<br /> 3.5. HAND OPERATED METERING FAUCETS SHALL REMAIN OPEN FOR 10 SECONDS(MIN)FOR LAVATORIES&SINKS PER SEC 1113-606.4,CBC i I I (n
<br /> THRESHOLD
<br /> 3.6. WATER CLOSET&URINAL FLUSH CONTROLS SHALL BE HAND-OPERATED OR AUTOMATIC,&SHALL BE LOCATED 44"(MAX)ABOVE THE PUSH SIDE-] _ i i W
<br /> FLOOR. SEC 1113-604.6&SEC 11@
<br /> H N" Sitar - REST ROOM J 8"(MIN) xTOE CLEARANCE NOTE:IFA(MIN)9"HT OF W Z
<br /> 4. TOILET&BATHING FACILITIES IDENTIFICATION SIGNAGE SHALL BE INSTALLED PER SEC 11B-703.7.2.6,CBC: (Y}=48"MIN IF OR HAS BOTH A LATCH&A MOT ROOM 6IGNACGr TOE CLEARANCE IS PROVIDED,A(MAX)OF 6" O z
<br /> 4.1. DOORWAYS LEADING TO TOILET ROOMS AND BATHING ROOMS SHALL BE IDENTIFIED BY A GEOMETRIC SYMBOL.THE SYMBOL SHALL BE CLOSER 11"{MINI OF THE 48"OF CLEAR FLOOR SPACE REQ'D L m
<br /> MOUNTED AT 58"(MIN)&60"(MAX)ABOVE THE FINISH FLOOR OR GROUND SURFACE MEASURED FROM THE CENTERLINE OF THE AT THE FIXTURE MAY EXTEND —
<br /> SYMBOL.WHERE A DOOR IS PROVIDED THE SYMBOL SHALL BE MOUNTED WITHIN 1"OF THE VERTICAL CENTERLINE OF THE DOOR. ' a'�C `g 0 ` �� ��� 5 TH O� INTO THE TOE
<br /> SPACE. Z U
<br /> 4.2. ALL GENDER TOILET AND BATHING FACILITIES SHALL BE IDENTIFIED BY A CIRCLE,1/4"THICK AND 12"IN DIAMETER WITH A 14"THICK
<br /> TRIANGLE WITH A VERTEX POINTING UPWARD SUPERIMPOSED ON THE CIRCLE AND WITHIN THE 12"DIAMETER.THE TRIANGLE SYMBOL I 3 w
<br /> SHALL CONTRAST WITH THE CIRCLE SYMBOL,EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND,THE CIRCLE a La
<br /> SYMBOL SHALL CONTRAST WITH THE DOOR,EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND PER CBC � TYPICAL SWING DOOR � a.
<br /> 116-703.F SIG3. GA. 1SCALE: NONE 2 TYPICAL THRESHOLD 3
<br /> 4.3. EDGES OF SIGNS SHALL BE ROUNDED,CHAMFERED OR EASED.CORNER OF SIGNS SHALL HAVE A MINIMUM RADIUS OF 1/8" H I GAS '� SCALE: NONE GA q TYPICAL WALL- LAV DETAILSCALE: NONE
<br /> 5. GRAB BARS: 56"
<br /> 5.1. GRAB BARS IN TOILET&BATHING FACILITIES SHALL COMPLY W/SEC 1113-609,CBC 48"SMOOTH.HARD, 11 FLUSH 19"(MIN)
<br /> 5.2. GRAB BAR CROSS-SECTION SHALL COMPLY W/SEC 1113-609.2,CBC NON-ABSORBENT (MIN) ACTIVATOR
<br /> 5.2.1. CIRCULAR CROSS-SECTIONS SHALL BE 1-1/4"0(MIN)TO 2"0(MAX) WAINSCOT SURFACE 48" ol 12" ON WIDE SIDE
<br /> 5.2.2. NON-CIRCULAR CROSS-SECTIONS SHALL HAVE A DIMENSION OF 2"(MAX)&A PERIMETER DIMENSION OF 4"(MIN)&4.8"(MAX (MIN) MA
<br /> 5.3. GRAB BAR SPACING SHALL COMPLY W/SEC 1113-609.3 WALL SIGN W/ Y4" 30"x48"CLR
<br /> 5.3.1. GRAB BAR SPACE BETWEEN THE WALL,PROJECTING OBJECTS BELOW&ENDS SHALL BE 1-1/2"(MIN) BRAILLE @ 60"HT 70, SPACE @ LAV r---------------- - ', —
<br /> 5.3.2. GRAB BAR SPACE BETWEEN PROJECTING OBJECTS ABOVE SHALL BE 12"(MIN) i I 4
<br /> 5.4. ALLOWABLE STRESSES SHALL NOT BE EXCEEDED FOR MATERIALS USED WHEN A VERT OR HORZ FORCE OF 250 POUNDS IS APPLIED(al I + w EDGE OF DINING TABLE O
<br /> ANY POINT ON THE GRAB BAR,FASTENER,MOUNTING DEVISE OR SUPPORTING STRUCTURE SEC 1113-609.8,CBC �° I ' I a + I OR WORK SURFACE
<br /> LEVER PRIVACY LATCH
<br /> 6. GROUND AND FLOOR SURFACES: A � I x J °C + �
<br /> 6.1. GROUND AND FLOOR SURFACES SHALL COMPLY WITH 1113-302,CBC.GROUND AND FLOOR SURFACES ALONG ACCESSIBLE ROUTES AND IN .E CD
<br /> W /� i ��� O 'D � i fy
<br /> " u i INSTALL 4"x4"
<br /> ACCESSIBLE SPACES SHALL BE STABLE,FIRM AND SLIP-RESISTANT. _ m �-'+ �! j ���� j I INTERNATIONAL SYMBOL
<br /> 6.2. CHANGES IN LEVEL UP T01/4 INCH MAY BE VERTICAL AND WITHOUT EDGE TREATMENT,CHANGES IN LEVEL BETWEEN 1/4"AND 112" - + I b I ` I I OF ACCESSIBILITY EA
<br /> r- ------1- _ L------------ ----� @
<br /> SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2.CHANGES IN LEVEL GREATER THAN 1/2"SHALL BE ACCOMPLISHED BY } L 1 _____ - — —— J ACCESSIBLE SPACE .�
<br /> MEANS OF A RAMP OR ELEVATOR PER SEC 1113-303,CBC, 12"DOOR SIGN @
<br /> 6.3. IF CARPET OR CARPET TILE IS USED ON A GROUND OR FLOOR SURFACE,THEN IT SHALL BE SECURELY ATTACHED;HAVE A FIRM 60"HT
<br /> CUSHION,PAD OR BACKING OR NO CUSHION OR PAD;AND HAVE A LEVEL LOOP,TEXTURED LOOP;LEVEL-CUT PILE,OR
<br /> LEVEL-CUT/UNCUT PILE TEXTURE.THE MAXIMUM PILE HEIGHT SHALL BE 1/2".EXPOSED EDGES OF CARPET SHALL BE FASTENED TO SMOOTH.HARD,NON- �........., ....,�...: V }-
<br /> FLOOR SURFACES AND HAVE TRIM ALONG THE ENTIRE LENGTH OF THE EXPOSED EDGE IN COMPLIANCE WITH SEC 1113-303,CBC PER SEC ABSORBENT FLOOR DINING TABLE OR
<br /> 116-302.2,CBC. SURFACE COVED 5" a ` O�p"y TOILIf INSULATED HOT WATER WORK SURFACE
<br /> 6.4. OPENINGS IN FLOOR OR GROUND SURFACES SHALL NOT ALLOW PASSAGE OF A SPHERE MORE THAN 112"0 EXCEPT AS ALLOWED IN UPWARD ONTO WALL &DRAIN PIPE
<br /> SECTIONS 11B-407.4.3,CBC 1-1/4"TO 1-1/2" 1-112"
<br /> 7. FIXED OR BUILT-IN SEATING,TABLE AND COUNTERS: NOMINAL DIAMETER - X11`
<br /> 7.1. A MINIMUM OF 5%BUT NOT LESS THAN ONE OF THE COUNTERS SHALL BE MADE ACCESSIBLE TO PERSONS WITH DISABILITIES. AN 54"(MIN) 36"(MIN)
<br /> ACCESSIBLE ROUTE OF TRAVEL SHALL BE PROVIDED COMPLYING WITH SEC 118-402,CBC,AND SHALL LEAD TO ACCESSIBLE COUNTERS r ......••
<br /> WALL i GRAB BAR - "' a U
<br /> PER SEC 118-226.1,CBC. 42"{MIN} 12"
<br /> 7.2. KNEE CLEARANCE OF AT LEAST 27 INCHES HIGH,30 INCHES WIDE AND 19 INCHES DEEP SHALL BE PROVIDED AT COUNTERS ACCESSIBLE 12" 24" ol 4
<br /> TO PERSONS WITH DISABILITIES PER SEC 1113-306.3,CBC. GRAB BAR 1W 36"GRAB (MIN (MIN)
<br /> 7.3. THE HEIGHT OF THE ACCESSIBLE COUNTERS SHOULD BE LOCATED BETWEEN 28 INCHES AND 34 INCHES ABOVE THE FINISHED FLOOR PER I BAR I i
<br /> SEC 11B-402.3,CBC. o N
<br /> 7.4. THE LENGTH OF THE ACCESSIBLE COUNTERS SHOULD BE A MINIMUM OF 36 INCHES,
<br /> CIA
<br /> z�0 0
<br /> wQwJ � • � U
<br /> 8. DRINKING FOUNTAINS: a o ' a - :x ,x
<br /> 8.1, DRINKING FOUNTAINS SHALL COMPLY WITH SEC 11B-307,1113-305&1113-602,CBC n 't ; d z m m TRANSFER SIDE
<br /> 8.2. OPERABLE PARTS SHALL COMPLY WITH SEC 11B-309,CBC: 17"-19"AFF
<br /> 8.2.1. THE FLOW OF WATER SHALL BE ACTIVATED 13Y A MANUALLY OPERATED SYSTEM THAT IS FRONT MOUNTED OR SIDE MOUNTED& I x REAR GRAB BAR
<br /> LOCATED WITHIN 6"OF THE FRONT EDGE OF THE UNIT,INCLUDING BUMPERS 7"_g" 17"-18" 19"(MIN)
<br /> 8.2.2. OPERABLE PARTS SHALL BE OPERABLE WITH ONE-HAND AND SHALL NOT REQUIRE GRASPING,PINCHING OR TWISTING OF THE ALLOWED AT 36"AFF
<br /> TYPE TOILET
<br /> WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS MAX AT TANK- Z w
<br /> WA
<br /> 8.3. THE SPOUT SHALL PROVIDE A FLOW OF WATER 4"HIGH(MIN)&SHALL BE LOCATED 5"(MAX)IN FRONT OF THE UNIT. THE ANGLE OF NO LL WvATION �Z
<br /> THE WATER STREAM SHALL BE MEASURED HORIZONTALLY RELATIVE TO THE FACE OF THE UNIT, WHERE SPOUTS ARE LOCATED LESS � w�
<br /> w
<br /> THAN 3"OF THE FRONT OF THE UNIT,THE ANGLE OF THE WATER STREAM SHALL BE 300(MAX). WHERE SPOUTS ARE LOCATED GCS59
<br /> BETWEEN 3"&5"{MAX}FROM THE FRONT OF THE UNIT,THE ANGLE OF THE WATER STREAM SHALL BE 150(MAX) 4 TYPICAL SINGLE OCC RCASCALE: NONE �A•
<br /> �
<br /> SCALE: NONE9. DRESSING ROOMS: TYP DINING 0R WORKSURFACE
<br /> SCALE: NONE 0
<br /> LGA. i a 9.1, DRESSING ROOMS SHALL COMPLY WITH SEC 1113-222&1113-803,CBCrd � o Z
<br /> 9.2. WHERE DRESSING,FITTING OR LOCKER ROOMS ARE PROVIDED,AT LEAST 5%,BUT NO FEWER THAN ONE,OF EACH TYPE OF USE,IN 0 o
<br /> -'
<br /> EACH CLUSTER SHALL COMPLY WITH SEC 1113-803,CBC a w
<br /> 9.3. WHERE COAT HOOKS OR SHELVES ARE PROVIDED IN DRESSING,FITTING OR LOCKER ROOMS WITHOUT INDIVIDUAL COMPARTMENTS,AT ?Z
<br /> LEAST ONE OF EACH TYPE SHALL COMPLY WITH SECTION 1113-803.5,CBC.WHERE COAT HOOKS OR SHELVES ARE PROVIDED IN o
<br /> INDIVIDUAL COMPARTMENTS AT LEAST ONE OF EACH TYPE COMPLYING WITH SECTION 116-803.5 SHALL BE PROVIDED IN INDIVIDUAL J
<br /> COMPARTMENTS IN DRESSING,FITTING,OR LOCKER ROOMS REQUIRED TO COMPLY WITH SECTION 11B-222.1,CBC. H Z
<br /> 9.3.1. COAT HOOKS PROVIDED WITHIN THE ROOM SHALL BE LOCATED WITHIN ONE OF THE REACH RANGES SPECIFIED IN SECTION 11B-308,
<br /> CBC 115"MIN&48"MAX AFF).SHELVES SHALL BE 40"{MIN)AND 48"(MAX)AFF OR GROUND.COAT HOOKS SHALL NOT BE
<br /> LOCATED ABOVE THE BENCH OR OTHER SEATING IN THE ROOM. G) w o
<br /> 9.4. WHERE MIRRORS ARE PROVIDED IN DRESSING,FITTING OR LOCKER ROOMS WITHOUT INDIVIDUAL COMPARTMENTS,AT LEAST ONE OF
<br /> EACH TYPE SHALL COMPLY WITH SECTION 1113-803.6,CBC.WHERE MIRRORS ARE PROVIDED IN INDIVIDUAL COMPARTMENTS AT LEAST g=l o
<br /> ONE OF EACH TYPE COMPLYING WITH SECTION 11B-803.6,CBC,SHALL BE PROVIDED IN INDIVIDUAL COMPARTMENTS IN DRESSING, c C'2U o
<br /> FITTING OR LOCKER ROOMS REQUIRED TO COMPLY WITH SECTION 11 B-222.1,CBG w m w a
<br /> 9.4.1. MIRRORS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE 20"IMAX)AFF OR GROUND,MIRRORS
<br /> SHALL BE FULL LENGTH WITH A REFLECTIVE SURFACE 18"WIDE(MIN)BY 54"HIGH(MIN)AND SHALL BE MOUNTED IN A POSITION =W
<br /> AFFORDING A VIEW TO A PERSON ON THE BENCH AS WELL AS TO A PERSON IN A STANDING POSITION, r z
<br /> 9.5. DOORS HALL NOT SWING INTO THE ROOM UNLESS A TURNING SPACE COMPLYING WITH SECTION 1113-304.3,CBC,IS PROVIDED BEYOND
<br /> THE ARC OF THE DOOR SWING. Q o
<br /> 9.6. A BENCH COMPLYING WITH SECTION 11B-903,CBC,SHALL BE PROVIDED WITHIN THE ROOM,
<br /> 9.6.1. BENCHES SHALL HAVE SEATS THAT ARE 48"LONG(MIN)AND 20"DEEP(MIN)OR 24"DEEP(MAX). -9c o
<br /> 9.6.2. THE BENCH SHALL PROVIDE FOR BACK SUPPORT OR SHALL BE AFFIXED TO A WALL ALONG ITS LONG DIMENSION.BACK SUPPORT m
<br /> SHALL BE 48"LONG(MIN)AND SHALL EXTEND FROM A POINT 2"(MAX)ABOVE THE SEAT SURFACE TO A POINT 18"IMIN)ABOVE W
<br /> THE SEAT SURFACE.BACK SUPPORT SHALL BE 2-1/2"(MAX)FROM THE REAR EDGE OF THE SEAT MEASURED HORIZONTALLY.
<br /> �Z
<br /> 9.6.3. THE TOP OF THE BENCH SEAT SURFACE SHALL BE 17"(MIN)AND 19"{MAX}ABOVE THE FINISH FLOOR OR GROUND. a
<br /> o�
<br /> 10. ACCESSIBLE PARKING: Q w
<br /> 10.1. HANDICAP PARKING&VAN SPACES SHALL BE INSTALLED PER SEC 118-502,CBC
<br /> 10.2. VEHICLE SPACES: CAR AND VAN PARKING SPACES SHALL BE 216"1181 LONG(MIN).CAR PARKING SPACES SHALL BE 108"f9')WIDE
<br /> �z
<br /> ¢a
<br /> DATE Og/13/18
<br /> DRAWN BY
<br /> Q?'OF ESS! DW
<br /> ����aP� R• sC s- CHECKED BY DRS
<br /> c+
<br /> W n JOB N0.
<br /> 7 xx c 32158 18.014
<br /> qGA. I SCALE: NONE : Exp. 12-31-18
<br /> CIVIL P GAA
<br /> 9TF OF' cgL1F�
<br /> OF 5 SHEETS
<br />
|