Laserfiche WebLink
a <br /> BENCH <br /> CE MACHINE <br /> B,4R EPDXY <br /> 101 FLOOR m <br /> TRAPZILLA TZ-600 <br /> 100 (E)COOLER GREASE INTERCEPTOR La <br /> (E)ADA SEATING (E)BAR <br /> COMPARTMENT 4Olin <br /> I _ <br /> SINK <br /> I .. 104 <br /> ARAM* 00 OD <br /> I I I I I I 1 I <br /> Fl-0-0-1a Lu <br /> 0 m oho <br /> EPDXYCD 0 <br /> I— I FLOOR O _w <br /> II � I I 11 <br /> :_i I I ♦ I Iv„ W Z <br /> 0 2t <br /> Fl o(0 fj <br /> _L__Ju 111 <br /> --- 3 V) <br /> .... <br /> I I I I 102 Q L w e <br /> ltl <br /> 1 r•~� i I r��` I I r��` f I �� I s ❑ ❑ <br /> I 1 1 I 1 <br /> (E)EPDXY S <br /> FLOOR <br /> r <br /> 1 a5 104 <br /> 1 _105 <br /> � D <br /> �f <br /> (E)HOOD (E)RANGE £ w" s <br /> s s $ ; <br /> s <br /> s <br /> s <br /> Owl I <br /> s 102 <br /> BENCH s <br /> (E)REFRIGERATOR (E]REFRIGERATOR y �3 <br /> Sir <br /> FOOD SERVICE SCOPE ❑F WORK K-00;z PLAN <br /> THIS PROJECT IS A PREVIOUS EXISTING RESTAURANT AND THE NEW OWNER IS REPLACING THE EXISTING 8G4LX, 3/8" <br /> GREASE TRAP WITH A NEW GREASE TRAP, THE THREE COMPARTMENT SINK AND ICE MACHINE TO BE <br /> RELOCATED TO WASTE AREA THE MAJORITY STAYING EXACTLY AS IT WAS IN THE PREVIOUS RESTAURANT, <br /> HEALTH DEPARTMENT N❑TESI <br /> a <br /> . WALK-IN COOLER TO BE FLASHED TO THE BUILDING'S WALLS AND CEILING ON ALL SIDES, <br /> co <br /> 2. COMPRESSORS AND CARB❑NATORS ARE TO BE SUPPORTED OFF THE FLOOR ON SIX INCH HIGH �� -s <br /> ROUND METAL LEGS OR OTHERWISE INSTALLED IN AN APPROVED MANNER S❑ AS TO BE EASILY <br /> ACCESSIBLE FOR CLEANING. <br /> 3. THE WATER SUPPLY FOR THE JANIT❑R SINK IS TO BE PROTECTED BY AN APPROVED BACKFLOW <br /> 0 <br /> PROTECTION DEVICE. ��----{{ ww <br /> w <br /> �'•-'1 z <br /> 0z <br /> . NG IS TO BE CONSTRUCTED S❑ AS TO BE EASILY CLEANABLE, AND INSTALLED •� M w w <br /> ON SIX INCH HIGH METAL LEGS, CANTILEVERED OR INSTALLED IN CONJUNCTI❑N WITH A <br /> PERMANENT, PROPERLY SEALED, FOUR INCH COVED BASE, ALL EQUIPMENT INCLUDING SHELVING o~ <br /> SHOULD BE SUPPORTED BY SIX INCH HIGH METAL LEGS, CASTORS OR COMPLETELY SEALED Q <br /> IN P❑STI❑N ON FOUR INCH COVED BASE. ALL STATIONARY EQUIPMENT NOT MENTIONED NOT o o <br /> MOUNTED ON SIX INCH HIGH LEGS MUST BE SEALED IN POSTI❑N WITH AN APPROVED SEALANT <br /> (I.E. SEAL THE JUNCTURE BETWEEN EQUIPMENT AND THE FLOOR OR SEAL THE CRACK OR SPACE UNDER <br /> CABINETS OR EQUIPMENT INSTALLED ON AN ELEVATED FOUR INCH HIGH ISLAND OR CURB), SILICONE O �d o <br /> ALANT IS AN APPR❑VED TYPE MATERIAL. IF JOINTS OR CRACKS ARE TOO WIDE (MORE THEN 1/6 INCH) L Z <br /> CONNECTOR STRIPS OR FLASHING MAY BE NECESSARY, USED IN CONJUNCTION WITH A SEALANT. a <br /> L� <br /> 5. CANOPY HOODS SHALL BE FLASHED TO THE CEILING AND ADJACENT WALLS. THE FLASHING SHALL BE m �3 <br /> a� <br /> CONSTRUCTED OF THE SAME MATERIAL AND THICKNESS AS THE HOOD, ALL JOINTS AND SEAMS SHALL J= <br /> N ~ <br /> BE LIQUID-TIGHT AND SMOOTH FOR EASE OF CLEANING, APPROVED CONSTRUCTION METHODS AND A�+D � �o <br /> MATERIALS SHALL BE USED FOR SEALING JOINTS AND SEAMS. POP RIVETS METSCREWS, OR OTHER o <br /> SIMILAR EXPOSED FASTENERS SHALL NOT BE USED ON THE INTERNAL SURFAA_CES OF A HOOD. •= a <br /> �Q <br /> 6. ANY NEW OR REMODELED HOODS WILL BE REQUIRED TO PASS AN AIR BALANCE AND PREFORMANCE TEST, <br /> ALL HOODS MUST HAVE AN AMOUNT OF MAKE-UP AIR SUPPLIED TO THE ROOM EQUAL TO THE AMOUNT OF •b � �U <br /> ATR TO BE EXHAUSTED. Z cc <br /> ,� w <br /> 7. ALL BUILDINGS ARE TO BE INSECT AND RODENT PROOFED, COMPLIANCE WILL BE DETERMINED AT THE TIME 6o <br /> OF THE HEALTH DEPARTMENTS FILED INSPECTI❑NS. WEATHER STRIPPING MUST BE INSTALLED AROUND ALL <br /> Cc <br /> DORS OPENING TO THE OUTSIDE. SELF CL❑SING DEVICES SHALL BE INSTALLED ON ALL EXTERIOR ❑PENIN r.--� Cc z Cr <br /> =a <br /> DOORS TO THE OUTSIDE, SELF CLOSING DEVICES SHALL BE INSTALLED ON ALL EXTERI❑R OPENING DOORS v F <br /> AND RESTROOM DOORS. IF ACCORDI❑N WINDOWS/DOORS ARE TO BE USED THEN THESE ALSO MUST BE �� •.� Z <br /> 'VECTOR-PROOF' AND HAVE EITHER SCREENS OR PROFESSIONALLY INSTALLED AIR BLOWERS. <br /> B. ALL FOOD MENU ITEMS ARE TO BE SUPPLIED BY AN INSPECTED AND APPROVED SOURCE. a <br /> Q� <br /> 9. ALL ELECTRICAL CONDUIT AND PLUMBING PIPING, DRAINS MUST BE INSTALL WITH-IN <br /> THE TOE SPACES OF CABINETS, AND WITH-IN WALLS, SEE DETAIL 2/K1. mm <br /> 10, ELECTRICIAN TO INTERCONNECT RESTROOM LIGHT SWITCH WITH EXHAUST FAN. <br /> KZ <br /> mo <br /> 11, ANY EXTERIOR ❑PENABLE WINDOWS MUST BE SCREENED WITH NOT LESS THAN 16 MESH SCREENING. ¢w <br /> 12. REFRIGERATI❑N STORAGE SHALL HAVE A MINIMUM LIGHT INTENSITY OF 20 FOOTCANDLES. z o <br /> m <br /> SIGNAGE o0 <br /> 13. A CONSPICU❑US SIGN IN EACH TOILET ROOM INDICATING CORRECT HAND WASHING PROCEDURES AFTER << <br /> USE OF TOILET, <br /> 14, PROVIDE SIGN AT EACH HAND SINK INDICATING CORRECT HAND WASHING PROCEDURES. <br /> 15. POST A SIGN IN FOOD PREPARATI❑N, STORAGE, UTENSIL CLEANING AND UTENSIL STORAGE AREAS, <br /> DATE 0$/13/1$ <br /> . SB 180 SIGN IS TO BE POSTED ATE ENTRANCES TO FACILITY SUCH THAT CUSTOMERS CAN SEE IT. <br /> DRAWN BY <br /> 17, PR❑VIDE FIRST AIb FOR CHOCKING SIGN POSTED IN A CONSPICU❑US PLACE OR PLACES IN ORDER DW <br /> fEss�oCHECKED BY <br /> THAT THE INSTRUCTI❑NS MAY BE CONSULTED BY ANYONE ATTEMPTING TO PROVIDE RELIEF TO A QRo <br /> �Qw� Pa S li) F DRS <br /> VICTIM IN A CH❑KING EMERGENCY, ti ti� <br /> y JOB NO, <br /> C 32158 1$•014 <br /> )E E(p. 12-31-18 )K <br /> , `P KlA <br /> orf <br /> CF CA1-1F"' <br /> OF 5 SHEETS <br />