PULL SIDE------i 25"(MAX) <br /> PULL SIDE <br /> z I I 24" MIN CLR @ EXT DRS I24"MIN <br /> 1. DOOR HARDWARE: 17"-25" FAUCET CONTROLS AND OPERATING <br /> 1.1. HAND ACTIVATED DOOR HARDWARE SHALL COMPLY WITH SECTIONS 118-309.4&116-404.2.7,CBC. OPERABLE PARTS OF HARDWARE I 18"MIN CLR @INT DRS I DOOR(SEE PLANT WITH <br /> SHALL BE 34"(MIN)&44"(MAX)FROM THE FINISH FLOOR OR GROUND. OPERABLE HARDWARE PARTS SHALL BE OPERABLE W1 o MECHANISMS SHALL BE OPERABLE <br /> a i �� r----------------- -- RE TIGHHT <br /> ONE-HAND&SHALL NOT REQUIRE TIGHT-GRASPING,PINCHING,OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE ONE HAND AND SHALL NOT TWISTING <br /> N aj <br /> AT 1:2 SLOPE x i v i GRASPING,PINCHING OR TWISTING OF THE y <br /> OPERABLE PARTS SHALL NOT EXCEED 5 POUNDS. I i TYPICAL THRESHOLD <br /> a WRIST.THE FORCE REQUIRED TO ACTIVATE <br /> WHEN PROVIDED,THRESHOLDS SHALL BE 1/2"'HIGH(MAX),PER SEC 11B-404.2.5,CBC. 2 CONTROLS SHALL BE NOT GREATER THAN a <br /> 1.2. r <br /> 1.2.1. THRESHOLDS W/A CHANGE IN LEVEL OF 1/4"(MAX),SHALL BE PERMITTER TO BE VERTICAL&WITHOUT EDGE TREATMENT,PER I I i 11 i X c i 0 k 5 lbf. LEVER-OPERATED,PUSH-TYPE AND <br /> SEC 118-303.2,CBC I I z <br /> FINISH FLOOR I �, LL i �.�; ELECTRONICALLY CONTROLLED <br /> 1.2.2. THRESHOLDS W/A CHANGE IN LEVEL BETWEEN 1/4"(MIN)&1/2"(MAX)SHALL BE BEVELED W/A SLOPE NOT STEEPR THAN 1:2, I I "' a I Z MECHANISMS ARE EXAMPLES OF <br /> PER SEC 11B-303.3,CBC I I Itj <br /> J ACCEPTABLE DESIGNS.SELF-CLOSING z <br /> 1.3. DOOR&GATE[LOSER'S SHALL BE ADJUSTED 50 THAT FROM AN OPEN POSITION OF 90',THE TIME REQ'D TO MOVE THE DOOR TO A °* I 12"MIN 24"MIN I __________ I VALVES ARE ALLOWED IF THE FAUCET N <br /> POSITION OF 12'FROM THE LATCH IS(5)SECONDS(MINI,PER SEC 116-404.2.8.1,CBC i i W/LATCH&CLOSER L PUSH SIDE_ I L J <br /> x - REMAINS OPEN FOR AT LEAST 10 SECONDS w <br /> PUSH i SIDE <br /> L_________J (Y)=48"MIN IF DR HAS A CLOSER c <br /> 2. DOORS: <br /> 2.1. THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE SHALL COMPLY W/SEC 11B-404.2.9,CBC,AS FOLLOWS: NOTE: LINE TYPE (------) LAtCN-6ID6 DOOR THRESHOLD KNIT GLE,4R,4NGE [PLAN) <br /> 2.1.1. INTERIOR HINGED DOORS&GATES: 5 POUNDS(MAX) REPRESENTS LEVEL MANEUVERING ► r <br /> 2.1.2. SLIDING OR FOLDING DOORS: 5 POUNDS(MAX) CLEARANCES AT DOORS PER SEC <br /> 11B-404.2.4,CBC.AREA SHALL NOT TO ------ <br /> 2.1.3. HINGED EXTERIOR DOORS: 5 POUNDS(MAX) r------ <br /> 2.1.4. REQUIRED FIRE DOORS: 15 POUNDS(MIN ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY) _--------------_--___--__� EXCEED 2�SLOPE IN ANY DIRECTION& i OUTSIDE <br /> SWINGING DOOR&GATE SURFACES WITHIN 10"OF THE FINISH FLOOR OR GROUND SURFACE SHALL HAVE A SMOOTH SURFACE ON THE PULL SIDE I SHALL SLOPE AWAY FROM THE EXTERIOR I I PROVIDE INSUL PIPE WRAP @EXPOSED WATER <br /> 2.2. 36" I I <br /> PUSH SIDE EXTENDING THE FULL WIDTH OF DOOR OR GATE. PARTS CREATING HORZ OR VERT JOINTS IN THIS SURFACE SHALL BE MIN i OF THE BUILDING(TYP) i &WASTE PIPING PER SEC 1113-604.5.1,CBC o <br /> WITHIN 1/16"OF THE SAME PLANE AS THE OTHER&SHALL BE FREE OF SHARP OR ABRASIVE EDGES. CAVITIES CREATED BY ADDED 00 v <br /> KICK PLATES SHALL BE CAPPED. SEC 11B-404.2.10,CBC I I _ <br /> MAX COMPRESSED <br /> 'O UNISEX,MEN OR WOMEN H/C DOOR i CARPET BELOW THRESHOLD _ '' ' '' <br /> 3. OPERABLE PARTS: i SIGN @ 60"HT <br /> LL COMPLY W/SEC11B-309,CBC FINISH FLOOR EVEN =� x x <br /> i ' Q <br /> 3.1. OPERABLE PARTS SHA U <br /> 3.2. A FORWARD OR PARALLEL CLEAR FLOOR SPACE OF 30"x48"(MIN)SHALL BE PROVIDED COMPLYING W/SEC 118-305,CBCco 00 00 <br /> _ <br /> 3.3. OPERABLE PARTS HEIGHT SHALL BE PLACED WITHIN THE REACH RANGES OUTLINED IN SEC 116-305,CBC 22" M11N i z UNISEX,MEN OR WOMEN H/C BRAILLE I I — — — � s <br /> 3.4. OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING,PINCHING,OR TWISTING OF THE I "' W <br /> } SIGN @ 60"HT <br /> WRIST.THE FORCE REQUIRED TO ACTIVATE SHALL BE 5 POUNDS(MAX),PER SEC 116309.4,CBC <br /> � I I Q .- c� o <br /> ND OPERATED METERING FAUCETS SHALL REMAIN OPEN FOR 10 SECONDS(MIN)FOR LAVATORIES&SINKS PER SEC 118-606.4,CBC i I I < \\ 0 <br /> 3.5. HA THRESHOLD <br /> CLOSET&URINAL FLUSH CONTROLS SHALL BE HAND-OPERATED OR AUTOMATIC,&SHALL BE LOCATED 44"(MAX)ABOVE THE -----PUSHi SIDE- ' I I `'Q o 0 0 <br /> 3.6. WATER L I REST ROOM <br /> FLOOR. SEC 1113-604.6&SEC 1113-605.3,CBC HINGE L__-------SIDE0. <br /> 8"(MIN) xTOE CLEARANCE NATE:IFA(MIN)9"HT OF W <br /> 4. TOILET&BATHING FACILITIES IDENTIFICATION SIGNAGE SHALL 8E INSTALLED PER SEC 116-703.7.2.6,CBC: (YI=48"MIN IF IDR HAS BOTH A LATCH&A RII3ST ROOM SIGNAGE TOE CLEARANCE IS PROVIDED,A(MAX)OF 6" O <br /> CLOSER c <br /> 4.1. DOORWAYS LEADING TO TOILET ROOMS AND BATHING ROOMS SHALL BE IDENTIFIED BY A GEOMETRIC SYMBOL.THE SYMBOL SHALL BE ill,(MIN) OAT THE F THE FIX U CLEAR FLOOR SPACE REQ'D CL <br /> " U SURFACE MEASURED FROM THE CENTERLINE OF THE THRIBSHOLDS SPACE. FIXTURE MAY EXTEND INTO THE TOE Z <br /> MOUNTED AT 58 (MIN)&60 (MAX)(MAXI ABOVE THE FINISH FLOOR OR GROUND APPROACHrms Gw INCA f NCS DOORS (', �- <br /> SYMBOL.WHERE A DOOR IS PROVIDED THE SYMBOL SHALL BE MOUNTED WITHIN 1"OF THE VERTICAL CENTERLINE OF THE DOOR. V 1CL z <br /> 4.2. ALL GENDER TOILET AND BATHING FACILITIES SHALL BE IDENTIFIED BY A CIRCLE,1/4 THICK AND 12"IN DIAMETER WITH A 14"THICK Q 0 <br /> TRIANGLE WITH A VERTEX POINTING UPWARD SUPERIMPOSED ON THE CIRCLE AND WITHIN THE 12"DIAMETER,THE TRIANGLE SYMBOL z <br /> OL EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND.THE CIRCLE <br /> SHALL CONTRAST WITH THE CIRCLE SYMBOL, Z <br /> SYMBOL SHALL CONTRAST WITH THE DOOR,EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND PER CBC � TYPICAL SWING DOOR SCALE: NO... 2 TYPICAL THRESHOLD 3 <br /> 11B-703.7.2.6.3. q SCALE: NONE GA 1 TYPICAL WALL- LAV DETAIL ❑ ❑ <br /> 4.3. EDGES OF SIGNS SHALL BE ROUNDED,CHAMFERED OR EASED.CORNER OF SIGNS SHALL HAVE A MINIMUM RADIUS OF 1/8" GA. I GA• <br /> SCALE: NONE <br /> 5. GRAB BARS: 56" <br /> 5.1. GRAB BARS IN TOILET&BATHING FACILITIES SHALL COMPLY W/SEC 116-609,CBC 48"SMOOTH.HARD, (MIN) FLUSH 19"(MIN) <br /> 5.2. GRAB BAR CROSS-SECTION SHALL COMPLY W/SEC 116-609.2,CBC NON-ABSORBENT 48" 12" ACTIVATOR <br /> loof <br /> 5.2.1. CIRCULAR CROSS-SECTIONS SHALL BE 1-1/4"0(MIN)TO 2"0(MAX) WAINSCOT SURFACE — ON WIDE SIDE <br /> 5.2.2. NON-CIRCULAR CROSS-SECTIONS SHALL HAVE A DIMENSION OF 2"(MAX)&A PERIMETER DIMENSION OF 4"(MIN)&4.8"(MAX (MIN) MA <br /> 5.3, GRAB BAR SPACING SHALL COMPLY W/SEC 116-609.3 [�ALL GENDER WALL SIGN W/ 24„ SP x E CLR �_ <br /> BRAILLE @ 60"HT <br /> 5.3.1. GRAB BAR SPACE BETWEEN THE WALL,PROJECTING OBJECTS BELOW&ENDS SHALL 8E 1-1/2"(MIN) SPACE @LAV r--------------- ----� <br /> 5.3.2. GRAB BAR SPACE BETWEEN PROJECTING OBJECTS ABOVE SHALL BE 12"(MIN) r I <br /> SHALL NOT BE EXCEEDED FOR MATERIALS USED WHEN A VERT OR HORZ FORCE OF 250 POUNDS IS APPLIED @ °� i ,,, I EDGE OF DINING TABLE <br /> 5.4. ALLOWABLE STRESSESH i OR WORK SURFACE <br /> ,� <br /> ANY POINT ON THE GRAB BAR,FASTENER,MOUNTING DEVISE OR SUPPORTING STRUCTURE SEC 11B-609.8,CBC LEVER PRIVACY LATCH I - I W <br /> z ° � - ��0\ <br /> o z I M Li o I � <br /> 6. GROUND AND FLOOR SURFACES: a i i �\ \� � I �ji INSTALL 4"x4" /!- <br /> 6.1. GROUND AND FLOOR SURFACES SHALL COMPLY WITH 116-302,CBC.GROUND AND FLOOR SURFACES ALONG ACCESSIBLE ROUTES AND IN m v i \� �} — I " INTERNATIONAL SYMBOL <br /> ACCESSIBLE SPACES SHALL BE STABLE,FIRM AND SLIP-RESISTANT. i Q' OF ACCESSIBILITY @ EA <br /> z <br /> 6.2. CHANGES IN LEVEL UP TO 1/4 INCH MAY BE VERTICAL AND WITHOUT EDGE TREATMENT.CHANGES IN LEVEL BETWEEN 1/4"AND 1/2" ; i r b4-----_y_ --------------- }- <br /> SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2.CHANGES IN LEVEL GREATER THAN 1/2"SHALL BE ACCOMPLISHED BY .� <br /> -— ——) ACCESSIBLE SPACE <br /> MEANS OF A RAMP OR ELEVATOR PER SEC 118-303,CBC. ALL GENDER 12"DOOR SIGN @ \ I I _ <br /> 60' HT -- <br /> 6.3. IF CARPET OR CARPET TILE IS USED ON A GROUND OR FLOOR SURFACE,THEN IT SHALL BE SECURELY ATTACHED;HAVE A FIRM I `y _ '� ' . z KNEE CLEARANCE (PLAN) <br /> CUSHION,PAD OR BACKING OR NO CUSHION OR PAD;AND HAVE A LEVEL LOOP,TEXTURED LOOP;LEVEL-CUT PILE,OR SMOOTH.HARD,NON- `••• - --- -a <br /> LEVEL-CUT/UNCUT PILE TEXTURE,THE MAXIMUM PILE HEIGHT SHALL BE 1/2".EXPOSED EDGES OF CARPET SHALL BE FASTENED TO ABSORBENT FLOOR DINING TABLE OR <br /> FLOOR SURFACES AND HAVE TRIM ALONG THE ENTIRE LENGTH OF THE EXPOSED EDGE IN COMPLIANCE WITH SEC 116-303,CBC PER SEC SURFACE COVED 5" SINGLE OCCUPANCY tOILET INSULATED HOT WATER WORK SURFACE <br /> 116-302.2,CBC. UPWARD ONTO WALL &DRAIN PIPE <br /> 6.4. OPENINGS IN FLOOR OR GROUND SURFACES SHALL NOT ALLOW PASSAGE OF A SPHERE MORE THAN 1/2"0 EXCEPT AS ALLOWED IN <br /> SECTIONS 1113-407.4.3,CBC NOMINAL <br /> DIAMETER NOMINAL DIAMETER <br /> 7. FIXED OR BUILT-IN SEATING TABLE AND COUNTERS: 54"(MIN) j 36"(MIN) <br /> 7.1. A MINIMUM OF 5%BUT NOT LESS THAN ONE OF THE COUNTERS SHALL BE MADE ACCESSIBLE TO PERSONS WITH DISABILITIES. AN -- <br /> GRAB BAR _ x <br /> ACCESSIBLE ROUTE OF TRAVEL SHALL BE PROVIDED COMPLYING WITH SEC 1113-402,CBC,AND SHALL LEAD TO ACCESSIBLE COUNTERS WALL\ <br /> PER SEC 116-226.1,CBC. 42"(MIN) 12" '� 12" 24'" <br /> S SHALL BE PROVIDED AT COUNTERS ACCESSIBLE <br /> 7.2. KNEE CLEARANCE OF AT LEAST 27 INCHES HIGH,30 INCHES WIDE AND 01 <br /> 19 INCHES DEEP GRAB BAR MA 36"GRAB 10 <br /> IMIN IMIN) z <br /> TO PERSONS WITH DISABILITIES PER SEC 11B-306.3,CBC. <br /> OF THE ACCESSIBLE COUNTERS SHOULD BE LOCATED BETWEEN 28 INCHES AND 34 INCHES ABOVE THE FINISHED FLOOR PER I BAR I z b <br /> 7.3. THE HEIGHT I N <br /> a <br /> SEC 11B-402.3,CBC. i <br /> 7.4. THE LENGTH OF THE ACCESSIBLE COUNTERS SHOULD BE A MINIMUM OF 36 INCHES. N �p o <br /> • a � <br /> W <br /> WQ W ❑ ��, /� 1 a0 <br /> z = 1= <= X % Lam/ <br /> a s = a 4 a z ® TRANSFER SIDE <br /> c + � o 17"-19"AFF m `O ,q <br /> 7 <br /> cn <br /> 17"-18" REAR GRAB BAR 19"'(MIN) • o <br /> 7'-9" ALLOWED AT 36' AFF <br /> AT TANK-TYPE TOILET <br /> w� <br /> ww <br /> :z L" <br /> KNEE CLEARANCE CPRCPILE� <br /> SIDE WALL ELEVATION RIM WALL ELEVATION _��p � w Z <br /> e° <br /> o <br /> 4 TYPICAL SINGLE OCC RR SCALE: NONE 5 TYP DINING OR WSCALE: NONE 6 015 0GA. GA. I GA. xx SCALE: NONE E� <br /> ow <br /> O =O <br /> Mw <br /> Z <br /> z <br /> \rI • ¢w <br /> J= <br /> O Z <br /> L7Ci C7� <br /> �O <br /> G7 O= <br /> VVn <br /> F--O <br /> LCA U <br /> w Z� <br /> w0 <br /> OfLLJ <br /> wp <br /> J <br /> a <br /> 0.� <br /> ao <br /> JD <br /> QW <br /> W� <br /> < <br /> QW <br /> �00 <br /> ZF- <br /> W <br /> y-O <br /> $Q <br /> zg <br /> ¢w <br /> V1 g <br /> U Q <br /> Z� <br /> W <br /> Q= <br /> O <br /> _J <br /> aza <br /> DATE 08/13/18 <br /> DRAWN BY <br /> QROF ESS/p� <br /> DW <br /> y��,o CHECKED BY <br /> 4N, DRS <br /> Z ,no kir" <br />