901
>
2800 - Aboveground Petroleum Storage Program
>
PR0521964
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/9/2019 11:22:44 AM
Creation date
3/1/2019 1:46:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0521964
PE
2832
FACILITY_ID
FA0012399
FACILITY_NAME
SWIFT TRANSPORTATION
STREET_NUMBER
901
STREET_NAME
DARCY
STREET_TYPE
PKWY
City
LATHROP
Zip
95330
APN
19822009
CURRENT_STATUS
01
SITE_LOCATION
901 DARCY PKWY
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ O 1` Q U I `IA,II, Environmental Health Department <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SWIFT TRANSPORTATION 901 D ARCY PKWY, LATHROP February 12, 2019 <br /> Other Violations <br /> 4030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> 4050 See below Unlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 618 CFR 112.7(e), 112.8(c)(6) Failed to keep records of procedures, inspections,or integrity tests for three years. <br /> The annual facility inspections called for by the SPCC plan under STI SP-001 standard, is not being performed. <br /> Inspections and testing shall be conducted on all aboveground liquid petroleum containers larger than 55 gallons, <br /> including all 55 gallon drums of oil. Records of these inspections and tests shall be signed by the appropriate <br /> supervisor or inspector and kept on site with the Spill Prevention, Control, and Countermeasure(SPCC) Plan for a <br /> period of three years. Immediately begin necessary testing and inspections for all Aboveground Petroleum Storage <br /> Act regulated containers and maintain on site with the SPCC Plan. <br /> This is a Class II violation. <br /> 714 CFR 112.8(c)(8)(kiv) Failed to provide each container with a high level monitoring device. <br /> The 1,000 gallon waste oil tank was observed with a broken direct vision gauge. At least one of the following <br /> devices must be installed in each container: <br /> -High liquid level alarm with audible or visual signal <br /> -High liquid level pump cutoff device set to stop flow at a predetermined content level <br /> -Direct audible or code signal communication between the container gauger and the pumping station <br /> -Fast response system, such as digital computer,telepulse, or direct vision gauge. If a direct vision gauge is <br /> being used for determining the liquid level of each tank, a person must be present to monitor gauges and the overall <br /> filling of the tanks. <br /> Immediately install an approved liquid level sensing device in accordance with CFR 112.8 and implement necessary <br /> procedures to ensure that the devices are fully functional and in use at all times during tank filling operations, or <br /> provide equivalence as allowed by CFR 112.7(a)(2). <br /> This was corrected on site. <br /> This is a Class II violation. <br /> 718 CFR 112.8(c)(11) Failed to locate properly or provide sufficient secondary containment for mobile/portable <br /> containers. <br /> The 55 gallon new oil drums inside the storage trailer and inside the maintenance shop were observed with <br /> insufficient secondary containment.The SPCC plan states that 55 gallon oil drums inside the storage trailer and <br /> maintenance shop should be on appropriately sized spill pallets or carts.The 55 gallon oil drums inside the storage <br /> trailer were observed without secondary containment. The 55 gallon drums of oil in the maintenance shop were <br /> observed on carts but did not seem capable of containing 55 gallons. Portable oil storage containers must be <br /> positioned or located to prevent a discharge and shall be furnished with a secondary means of containment <br /> sufficient to contain the capacity of the largest single container with sufficient freeboard to contain precipitation. <br /> Immediately provide sufficient secondary containment for this and all other portable containers at this facility, or <br /> provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> FA0012399 PR0521964 SCO01 02/12/2019 <br /> EHD 28-01 Rev.09/27/2018 Page 4 of 5 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.