My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
441
>
2900 - Site Mitigation Program
>
PR0544208
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2019 4:53:08 PM
Creation date
3/1/2019 3:56:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0544208
PE
2957
FACILITY_ID
FA0003628
FACILITY_NAME
ARCO STATION #2168*
STREET_NUMBER
441
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
14707607
CURRENT_STATUS
02
SITE_LOCATION
441 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
250
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Chuck Carmel Page 4 <br /> The need for a groundwater investigation at this site was also discussed at the meeting. The <br /> laboratory results showing contamination at a depth of 45 feet BGS in B-13/VW-5 (and to varying <br /> depths in other borings), the field observations and PID readings indicating contamination to depths <br /> of approximately 59' BGS, the sandy porous soil underlying the site and the seasonal high depth to <br /> groundwater of approximately 40' BGS indicate the need to verify that groundwater has not been <br /> impacted at this site. A proposal to include the installation of monitoring wells during the next phase <br /> of field work can be done by way of an addendum to the work plan. <br /> Facility 6080 at 85 E. Louise, Lathrop <br /> PHS/EHD contact - Linda Turkatte <br /> Discussed at the meeting was the issue of the contamination that was detected in the groundwater <br /> sample recently collected from the area of the former waste oil tank at this site. The accuracy of <br /> groundwater results using a hydropunch-type instrument (as was the case for the collection of this <br /> groundwater sample)versus using a conventional monitoring well was discussed. Documentation was <br /> mentioned of case studies showing a close relationship between the two sampling methods. PHS/EHD <br /> will review these case studies if they are submitted. However,regardless of the method used to obtain <br /> the sample, it did show contamination in the groundwater, as "miscellaneous' hydrocarbons. <br /> More information is needed from this site before a determination can be made as to any future work <br /> needed or if closure is warranted. Additional information that would be helpful are the type or types <br /> of hydrocarbons present (possibly through use of additional analytical methodologies), the source of <br /> these hydrocarbons (as there may be other possible sources located at the site) and the full extent of <br /> these hydrocarbons in the groundwater. Any information on the former gasoline tanks that were <br /> removed before 1984 would also be helpful and should also be submitted to PHS/EHD. This <br /> information is needed for PHS/EHD to make an effective evaluation of the groundwater quality at <br /> this site. <br /> Although not discussed at the meeting,PHS/EHD recommends that the existing monitoring wells at <br /> this site be sampled at least on a yearly basis. <br /> It was suggested that all parties meet again in three months to maintain consistency and <br /> communication.PHS/EHD will be pleased to schedule Wednesday,June 30, 1993 for the purpose of <br /> following up the March 30th meeting. <br /> Please contact Margaret Lagorio, (209) 468-3449 or Diane Hinson, (209) 468-3452 of my staff to confirm the <br /> tentative date. <br /> Jogi Khanna, M. , M.P.H. <br /> Health OfiiIZ <br /> �0 <br /> uric A Cotulla, REHS, Program Manager <br /> Environmental Health Division <br /> LAC/ML:lb <br /> c: H.C. Windsor c: J. Bobbitt <br /> c: K Christie c: J. Johnson <br /> c: J. Lucas c: E. Thayer, CVRWQCB <br />
The URL can be used to link to this page
Your browser does not support the video tag.