EXISTING LENNOX GCS16 7.5 TON DINING AREA ROOFTOP AIR CONDITIONING UNIT&ITS AIR DISTRIBUTION SYSTEM <br /> (DUCTWORK&AIR DEVICES)TO BE REMOVED UNDER DEMOLITION WORK. COORDINATE WITH DEMOLITION <br /> CONTRACTOR. <br /> I <br /> EXISTING LENNOX LGA120 10 TON KITCHEN AREA ROOFTOP AIR CONDITIONING UNIT INCLUDING AIR DEVICES TO <br /> BE REMOVED UNDER DEMOLITION WORK. EXISTING MAIN RECTANGULAR SUPPLY DUCT&CONNECTED ROUND _ <br /> SUPPLY DUCTS TO REMAIN. ITS RETURN AIR DUCT DISTRIBUTION SYSTEM TO REMAIN BUT RETURN REGISTERS TO <br /> BE REMOVED UNDER DEMOLITION WORK. VERIFY IF EXISTING ROOF CURB CAN BE REUSED BEFORE STARTING 16� � —_ <br /> 0. DEMOLITION WORK. COORDINATE WITH DEMOLITION CONTRACTOR. <br /> S-4 <br /> _ _ - ----- aa,00aa <br /> I 310 <br /> t-o <br /> W Z .,EXISTING GREASE EXHAUST HOODEXHAUST FAN &CONNECTED DUCTWORK TO REMAIN -- <br /> o <br /> --- - -- - -- --._._ .I - - -- --� 340 i S o <br /> ��..._ - <br /> \ I <br /> a EXISTING TOILET EXHAUST FAN &CONNECTED EXHAUST DUCT THRU ROOF TO REMAIN. REMAIN[NG DUCTWORK __ _ -- 17 - °°° °°° - ---- <br /> LU <br /> RUNNING TO EXHAUST REGISTERS ALONG WITH EXHAUST REGISTERS TO BE REMOVED UNDER DEMOLITION WORK.LD <br /> I 1 <br /> a z COORDINATE WITH DEMOLITION CONTRACTOR. J —' I f` <br /> ALL REMAINING ABANDONED HVAC EQUIPMENT, DUCTWORK, ETC.TO BE REMOVED, COORDINATE WITH 4 z — - z - <br /> \ 310 3 0 i - (E}fj"� <br /> DEMOLITION CONTRACTOR, 12f� \ 20 <br /> 1 <br /> 310 310 ("LU 10,10 <br /> F-W '._....._ <br /> --- LJ ....: ... ._ `.. --\ -- " 19 ......_ �/ 400 2 13 11 °oo°ao°n° r <br /> LU <br /> - - - ..-- ---� �- ----1 -- - - -- 40r- <br /> 4m <br /> Vm] archtecture <br /> 13 J \ 1z ° Design Planning lnteriars <br /> 12 � - 4� r � 50i 637 5th AVenue San Rafael, CA 94901 <br /> 13 12' 1-- o 415 451 2500 415 451-2595 fax <br /> WWW.VI71afGll-00171L- <br /> aso °�° N {E)14 (E)14 0 2 _..as VMI JOB NUMBER <br /> w U 16(� - (E)8 0 C)oLL <br /> [- ...- --__ ---- -- ------._.. ... a!� 1769 <br /> � r10017; 14� �1 100AR <br /> 6� <br /> AM <br /> _ t16�0 <br /> � <br /> rr <br /> 610 <br /> x <br /> LU <br /> No. C17928 <br /> ._... __.. _..._ _ _ <br /> z °r °, °o° 18 <br /> �a _. _..._ - -- -- ----- - -__ � _..T ---- -- _ ---- -..... -- --- -- __ _ REN, 10131119 <br /> w 1 s 1 a a ] ,(12"0 i -2 s AC-2 - aovo° aoo <br /> 0 500 500 500 500 1D0 ?°o oao' - � <br /> �J �^ o v anon <br /> { <br /> I <br /> a"� ° I CA <br /> LU LL, <br /> MECHANICAL DEMOLITION NOTES G - - - -- --I ---- �_...._- - 17x ° z �+ -- ! -� <br /> - J 2 1450 <br /> ITEM OA RA SA EA PRESSURE -- -- -----. _ - -. . .._..--- -.... .. --- ----.m._ _..._ _ -_ <br /> LU <br /> � 1 ��, <br /> c AC-1 1000 2500 3500 - +1000 _ soLU <br /> — <br /> LA <br /> T. <br /> o z - 2900 3500 -- +600 <br /> wa <br /> Lw o <br /> 0 <br /> zd <br /> w (E) HOOD EF -- - - 1100 -1100 (VERIFY) <br /> vi o <br /> zco <br /> oz <br /> o (E) TOILET EF - - 400 -400 <br /> �w <br /> s <br /> o� <br /> D <br /> CIO 6U_ <br /> TOTAL 1600 =1500 +ton <br /> 6 <br /> Ua AIR BALANCE CFM SCHEDULE F <br /> MECHANICAL FLOOR PLAN 1/4"=11-a" A <br /> RECORD DATES <br /> 2 In W � NEW LENNOX 10 TON ROOFTOP A.C. UN4T TO REPLACE SMALLER SIZE LENNOX GCS16 7.5 TON ROOFTOP A.C. UNIT INSTALL ON 10 EXISTING 30x12 SUPPLY DUCT TO REMAIN. <br /> yo FAN DATA COOLING CAPACITY HEATING CAPACITY UNIT ELECT DATA NEW FACTORY FACTORY CURB. DD SUBMITTAL <br /> uj MAX <br /> UNIT AREA SERVED 0 TRAM" & 16"x20"DUCTS INSTALLED 6"ABOVE BOTTOM OF EXISTING TRUSSES, 3500 C O SUPPLY DUCT TO REMAIN. BLDG.SUBMITTAL 5!2512018 <br /> MANUFACTURER 11 EXISTING 8" <br /> i� MIN CAP UNIT 2 TRANSITION TO 28"x20" SUPPLY DUCT DOWN FROM ROOFTOP AC UNIT AC-1 WITH 12"/16"VERTICAL SPLIT TO 2 HORIZONTAL BID SET <br /> SUPPLY MIN O.A. NOM MIN INPUT OUTPUT VOLTS/ AND <br /> Lo <br /> CFM CFM ESP HP RPM TONS (MBH) EER (MBH) (MBH) STAGES AFUE PH MCA MOCP WEIGHT MODEL NUMBER FIELD VERIFIED BEFORE BIDDING. FM,ACTUAL CONDITIONS NEED TO BE 1z EXISTING 14°0 SUPPLY DUCT TO REMAIN. <br /> 0 o TDT/SEN (LBS) 13 CONNECT TO EXISTING ROUND BANCH SUPPLY DUCT.VERIFY SIZE, LOCATION &POINT OF CONNECTION, CONTRACT SI=T <br /> 5 TRANSITION TO LINED 24"x26"RETURN PLENUM DOWN FROM ROOFTOP AC UNIT AC-1 WITH BOTTOM ABOVE EXISTING TRUSSES <br /> 11 LENNOX WITH 1610 SIDE CONNECTIONS, 2500 CFM.ACTUAL CONDITIONS NEED TO BE FIELD VERIFIED BEFORE BIDDING. 14 CONNECT 10"0 USING SPIN-IN EXTRACTOR TO EXISTING 30x12 DUCT BETWEEN TRUSSES, VERIFY POINT OF CONNECTION. REVISIONS <br /> AC-1 DINING 3500 1000 .5 3 1000 10 120/96 12 130 104 2 80 20$13 46 50 1600 LGH120H4BS1Y CONNECT 1210 TO SIDE OF RECTANGULAR SUPPLY DUCT RUNNING BETWEEN TRUSSES USING SPIN-fN EXTRACTOR &RUN 15 CONNECT TO EXISTING 8"0 DUCT ABOVE CEILING, VERIFY SIZE&LOCATION. REMOVE ABANDONED DUCTWORK BEYOND. <br /> < o THRU TRUSS SPACE TO CEILING DIFFUSER, TYPICAL. 12"0 INSULATED DUCTS TO RUN THROUGH OPEN WEBBING OF EXISTING <br /> Z o LENNOX <br /> Q Q AC-2 KITCHEN 3500 600 .5" 3 1000 10 120196 12 130 104 2 80 208/3 46 50 1500 TRUSSES. FIELD VERIFY THAT EXISTING WEBBING OPENING SIZES WILL ALLOW PASSAGE OF DUCTWORK BEFORE BIDDING, 16 NEW CEILING DIFFUSER TO REPLACE EXISTING, CONNECT TO EXISTING DUCT. <br /> 0 0 o LGH120H48SIY TYPICAL FOR 7. <br /> CD �� NOTES 0 COMBINATION SUPPLY/RETURN DROP DIFFUSER&DUCTWORK TO BE REMOVED IN DEMOLITION WORK 17 EXISTING CEILING DIFFUSER&CONNECTED DUCTWORK TO BE REMOVED. <br /> 1a EXISTING EXHAUST REGIISTER &CONNECTED DUCTWORK TO BE REMOVED. <br /> � o� 1. DOWN DISCHARGE PACKAGED GAS/ELECTRIC ROOFTOP UNIT WITH MINIMUM 2 STAGE COOLING&2 STAGE HEATING. ® NEW LENNOX 10 TON ROOFTOP A.C. UNIT TO REPLACE LENNOX LGA120 10 TON ROOFTOP A.C. UNIT HAVING SIMILAR CURB, <br /> VERIFY IF EXISTING ROOF CURB CAN BE REUSED, INSTALLING A NEW FACTORY CURB IF NOT. CONNECT TO EXISTING SUPPLY& 19 VOLUME DAMPER,TYPICAL, <br /> 2. OPTIONS INCLUDE HINGED ACCESS DOORS, 2" MERV 8 FILTERS, LOW LEAKAGE ECONOMISER, BAROMETRIC RELIEF DAMPER, TIME GUARD,COIL GUARD, FACTORY ROOF CURB {VERIFY AC-2), RETURN DUCTS THRU ROOF FROM REMOVED A.C. UNIT. THE SUPPLY&RETURN CONNECTIONS NEED TO BE FIELD VERIFIED <br /> BEFORE BIDDING, BEING THAT ACTUAL CONDITIONS ARE UNKNOWN z� "'^T'"'^T ""^ERATURE CONTROL PANEL TO REMAIN CONNECT CONTROL WIRING SERVING REMOVED A,C, UNITS TO NEW A.C. <br /> p o POWERED 120 VOLT CONVENIENCE OUTLET AND FACTORY INSTALLED SMOKE DUCT DETECTOR IN THE SUPPLY PLENUM OF UNIT. UNITS REPLACING THEM ALONG WITH RELOCATED REMOTE SENSOR, VERIFY SYSTEM COMPATABILiTY WITH NEW A.G. UNITS. <br /> �_ EXISTING RETURN DUCTWORK TO REMAIN, REPLACE 2 RETURN REGISTERS WITH 2 NEW RETURN REGISTERS R-2. <br /> � a� Q <br /> NEW THERMOSTAT FOR AC-1 TO REPLACE EXISTING, VERIFY LOCATION WITH OWNER'S CONSTRUCTION MANAGER. <br /> o ® EXISTING ROOFTOP GREASE EXHAUST FAN,TYPE 1 HOOD & INTERCONNECTING DUCT TO REMAIN. CLEAN, INSTALL.NEW BELT <br /> o AND ADJUST TO 1100 CFM. RELOCATED THERMOSTAT FOR EXISTING A.C. UNIT AC-3E,VERIFY LOCATION WITH OWNER'S CONSTRUCTION MANAGER. <br /> zw � EXISTING ROOFTOP TOILET EXHAUST FAN &DUCT THRU ROOF'TO REMAIN. ADJUST FAN TO 400 CFM &CONNECT NEW 10"0 TO CLIENT <br /> 0 cn EXISTING DUCT THRU ROOF. JEANELLE, INC, <br /> a 2111 W.Kettleman Ln.,Suite E <br /> AIR CONDITIONING UNIT SCHEDULE E HVAC KEY NOTES g Lodi,Ca.95242 <br /> m <br /> DIFFUSER FACE <br /> TYPE AIR MOUNTING DUTY MATERIAL ALL WORK AND MATERIALS SHALL,COMPLY WITH 2013 CALIFORNIA MECHANICAL CODE&ALL OTHER GOVERNING CODES. OBTAIN &PAY FOR ALL NECESSARY PERMITS,FEES&INSPECTIONS REQUIRED BY GOVERNING AUTHORITIES STORE; # <br /> 9 o_ NECK OR w � w PATTERN z � NEW A.C.UNITS AC-1 &AC 2*TO BE MOUNTED ON NEW FACTORY CURB BOLTED TO ROOF TRUSSES OR BLOCKING &FLASHED WATER TIGHT INTO EXISTING ROOFING (*IF EXISTING CURB OF REMOVED SIMILAR SIZED 10 TON A.C. UNIT CAN NOT BE REUSED). <br /> MARK z U) !- U cc "' MANUFACTURER MODEL NUMBER REMARKS PROJECT <br /> SIZE CEILING GRID D ! Q c z Lu <br /> 100 o LL 0 oc CFM ° NEW DUCTWORK TO BE FABRICATED, INSTALLED AND SEISMICALLY BRACED PER CALIFORNIA MECHANICAL CODE CHAPTER 6 AND SMACNA HVAC DUCT CONSTRUCTION STANDARDS MANUAL. TACO BELL REMODEL <br /> I-- � SIZE o RANGE g W �" w ui Q NEW ROUND SUPPLY&RETURN DUCTS TO BE WRAPPED RIGID SHEETMETAL,WITH THE EXCEPTION OF THE LAST 5'-0", WHICH MAY BE FLEX. <br /> 1364 BUSINESS PARK DRIVE <br /> [ 0 0 4W NEW RECTANGULAR SUPPLY DUCTS TO BE WRAPPED AND RETURN PLENUMS TO BE LINED SHEETMETAL WITH TURNING VANES IN ELBOWS. LODI, CA. 95240 <br /> M .; S 1 7 12"0 24x24 X X X X TITUS TMSA AA BLACK FINISH,OBD <br /> o i 500 NEW TOILET EXHAUST DUCTS TO BE RIGID SHEETMETAL. APN # <br /> `" VERTICAL <br /> S-2 6 18x18 24x24 X X X X TITUS PAS AA NO DEFLECTORS,OBD MATERIALS EXPOSED WITHIN DUCTS OR PLENUMS TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH CALIFORNIA MECHANICAL CODE SECTION 602.2. <br /> W W 270-400 <br /> DUCT AND PLENUM LINING TO BE MOLD, HUMIDITY AND EROSION RESISTANT, COMPLYING WITH CALIFORNIA MECHANICAL CODE SECTION 604.1, <br /> �[ S 3 3 12x12 24x24 X 4W X X X TITUS PCS-AA OPPOSED BLADE DAMPER <br /> m a 1W 300 400 DUCT INSULATING WRAP TO BE AT LEAST 1"THICK WITH A FRK FOIL VAPOR BARRIER &HAVE A MINIMUM R VALUE OF 3.5, <br /> ZF=Lcua S-4 2 8x8 24x24 X X X X TITUS PCS-AA OPPOSED BLADE DAMPER SMOKE DETECTOR SHALL BE FACTORY INSTALLED IN EACH NEW A.0 UNIT SUPPLY AIR PLENUM AND SHALL DEACTIVATE THE A.C. UNIT UPON SENSING SMOKE PER CALIFORNIA MECHANICAL CODE REQUIREMENTS. <br /> a 4'w S-6 2 6x6 11x11 X 1W 100 X X X TITUS TDGAA OPPOSED BLADE DAMPER ALL OUTSIDE AIR INTAKES SHALL BE A MINIMUM OF 10'-0" FROM EXHAUST FANS, FLUE TERMINATIONS AND PLUMBING VENTS, EXPLORER <br /> to Q 8 FINAL HVAC SYSTEM TESTING AND BALANCING TO BE BY A CERTIFIED AIR BALANCER CONTRACTED BY THE HVAC CONTRACTOR, <br /> K50 SUCCESSOR,"-"DATE <br /> Q R-1 2 22x22 24x24 X NA X X X TITUS PAR-AA BLACK FINISH,OBD NEW A.C. UNITS TO BE CONTROLLED BY NEW PROGRAMMABLE T-STAT WITH AUTO CHANGEOVER REPLACING a. CING EXISTING. COORDINATE T-STAT LOCATION WITH OWNER'S CONSTRUCTION MANAGER. <br /> RECONNECTION OF GAS AND CONDENSATE DRAIN PIPING TO NEW AIR CONDITIONING UNITS BY PLUMBING CONTRACTOR. <br /> z R-2 2 22x22 24x24 X NA X X X TITUS PAR-AA OPPOSED BLADE DAMPER <br /> uoi[ z NA 1450 LOW VOLTAGE CONTROL WIRING AND ENCLOSING CONDUIT IN THIS WORK. LINE VOLTAGE WIRING BY ELECTRICAL CONTRACTOR. MECHANICAL <br /> p C L <br /> E 1 2 8x8 10x10 X 150 X X X TITUS 8F OPPOSED BLADE DAMPER EXISTING BLOWER INTERLOCK SWITCHING SYSTEM FOR EXISTING GREASE HOOD EXHAUST FAN AND NEW(REPLACING EXISTING) A.G. UNIT BLOWERS TO REMAIN IN COMPLIANCE WITH REQUIREMENTS OF THE CALIFORNIA MECHANICAL CODE. PLAN <br /> cu <br /> z <br /> CD—E <br /> `ul �CD E-2 1 6x6 8x8 X NA X X X TITUS 8F OPPOSED BLADE DAMPER <br /> 0 0 100 <br /> w <br /> mi no <br /> o� <br /> cc <br /> Q AIR DEVICE SCHEDULE D HVAC NOTES 1C <br />