Laserfiche WebLink
t <br /> �1 MONITORING WELL PURGING PROTOCOL <br /> MEASURE AND RECORD DEPTH TO WATER AND <br /> WELL TOTAL DEPTH <br /> OWT <br /> CHECK FOR FLOATING PRODUCT <br /> YES NO <br /> MEASURE AND DOCUMENT CALCULATE PURGE VOLUME BY <br /> FLOATING PRODUCT THICKNESS USING THE FOLLOWING EQUATION <br /> P= nr' x748x3 <br /> DO NOT SAMPLE WELL FOR <br /> where <br /> DISSOLVED CONSTITUENTS <br /> P=calculated purge volume(gallons) <br /> n=3 14 <br /> r=radius of well casing in feet <br /> h=height of water column in feet <br /> EVACUATE WATER FROM WELL EQUAL TO <br /> THE CALCULATED PURGE VOLUME WHILE <br /> WELL EVACUATED TO PRACTICAL LIMITS MONITORING GROUNDWATER <br /> OF DRYNESS BEFORE REMOVING STABILIZATION INDICATOR PARAMETERS <br /> CALCULATED PURGE VOLUME (pH, CONDUCTIVITY,TEMPERATURE)AT <br /> INTERVALS OF ONE CASING VOLUME <br /> NO YES <br /> FINAL TWO SETS OF GROUNDWATER <br /> STABILIZATION INDICATOR PARAMETER <br /> MEASUREMENTS MEET THE FOLLOWING <br /> CRITERIA WELL RECHARGES TO A LEVEL <br /> pH =±0 1 pH units SUFFICIENT FOR SAMPLE <br /> COND =± 10% COLLECTION WITHIN 24 HOURS <br /> TEMP =± 1 0°F 1OF EVACUATION TO DRYNESS <br /> YES NO YE5 NO <br /> WELL PURGING CONTINUE PURGING, EVACUATE FIELD TEST FIRST RECORD WELL <br /> CRITERIA MET, ADDITIONAL CASING VOLUME RECHARGE WATER FOR AS DRY FOR <br /> PROCEED TO OF WATER, MONITORING INDICATOR PARAMETERS, PURPOSES OF <br /> WELL SAMPLING INDICATOR PARAMETERS FOR THEN PROCEED TO WELL SAMPLING <br /> STABILITY SAMPLING <br /> FIGURE <br /> EMCON MONITORING WELL PURGING PROTOCOL A-1 <br />