My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0012861
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
441
>
2900 - Site Mitigation Program
>
PR0544208
>
ARCHIVED REPORTS XR0012861
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2019 6:15:48 PM
Creation date
3/1/2019 4:44:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0012861
RECORD_ID
PR0544208
PE
2957
FACILITY_ID
FA0003628
FACILITY_NAME
ARCO STATION #2168*
STREET_NUMBER
441
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
14707607
CURRENT_STATUS
02
SITE_LOCATION
441 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
248
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> i <br /> San Joaquin Valley <br /> Air Pollution Control District <br /> E <br /> AUTHORITY TO CONSTRUCT <br /> F <br /> PERMIT NO: N-7375-1-0 ISSUANCE DATE: 08/07/2006 `. <br /> } <br /> LEGAL OWNER OR OPERATOR: ATLANTIC RICHFIELD COMPANY <br /> MAILING ADDRESS: 2870 GATEWAY OAKS DR, STE 150 = j <br /> SACRAMENTO, CA 95833-3577 <br /> � 1 <br /> LOCATION: 441 W CHARTER WAY <br /> t Y <br /> STOCKTON, CA <br /> EQUIPMENT DESCRIPTION: <br /> GROUNDWATER REMEDIATION PROJECT SERVED BY A 33 KW H2 OIL RECOVERY EQUIPMENT MODEL H2CO- <br /> 200E ELECTRIC CATALYTIC OXIDIZER <br /> CONDITIONS <br /> 1. The groundwater remediation system shall be maintained in proper operating condition at all times. [District Rule <br /> 2201] <br /> l ' 2. No air contaminant shall be discharged into the atmosphere for a period or periods aggregating more than three <br /> F, minutes in any one hour which is as dark as, or darker than,Ringelmann 1 or 20%opacity. [District Rule 4101] <br /> 3. No air'contaminant shall be released into the atmosphere which causes a public nuisance. [District Rule 4102] <br /> 4. Either the VOC control efficiency shall not be less than 95%,or the total VOC emission rate shall not exceed 2 pounds <br /> in any one day. [District Rule 2201]F. <br /> i <br /> 5. The total VOC emissions from the groundwater remediation system served by the catalytic oxidizer shall not exceed ' <br /> 17.1 pounds in any one day. [District Rule 2201] <br /> 6. The TPHg concentration of the exhaust gas from the groundwater remediation system,served by the catalytic oxidizer <br /> shall not exceed 3,000 ppmv, measured at the inlet to the catalyst bed downstream of the air dilution point. [District <br /> Rule 2201] <br /> 7. The effluent gas tlowrate after the control device shall not exceed 300 scfm. [District Rule 2201] <br /> 8. The effluent VOC concentration level after the control device shall not exceed 150 ppmv. [District Rule 2201] <br /> F9. The minimum operating temperature for the combustion chamber of the catalytic oxidizer shall be maintained at or <br /> above 600 degrees F. [District Rule 2201] <br /> CONDITIONS CONTINUE ON NEXT PAGE <br /> YOU MUST NOTIFY THE DISTRICT COMPLIANCE DIVISION AT (209) 557-6400 WHEN CONSTRUCTION.IS COMPLETED AND PRIOR TO <br /> OPERATING THE EQUIPMENT OR MODIFICATIONS AUTHORIZED BY THIS AUTHORITY TO CONSTRUCT. This is NOT a PERMIT TO OPERATE, <br /> F, Approval or denial of a PERMIT TO OPERATE will be made after an inspection to verify that the equipment has been constructed in accordance with the <br /> approved plans, specifications and conditions of this Authority to Construct, and to determine if the equipment can be operated in compliance with all <br /> Rules and Regulations of the San Joaquin Valley Unified Air Pollution Control District Unless construction has commenced pursuant to Rule 2050,this <br /> Authority to Construct shall expire and application shall be cancelled two years from the date of issuance. The applicant is responsible for complying with <br /> all laws,ordinances and regulations of all other governmental agencies which may pertain to the above equipment. <br /> Seyed Sad redin, Executive Director/APCO <br /> cr�cr� <br /> F1 <br /> �DAV WARNERDiretor� ,P frSeServices <br /> o:wo6 'nmnit <br /> c <br /> Northern Regional Once • 4800 Enterprise Way 9 Modesto,CA 95356-8718 • (209)557-6400 a Fax(209)557-6475 <br />
The URL can be used to link to this page
Your browser does not support the video tag.