Laserfiche WebLink
Depth Qt Fs Pw Fs/Qc Soii benavior iype Irl <br /> (ft) (TSF) (TSE) (PSI) M Zone UBC-1983 60% Hamm <br /> 67 09 56 9 3 200 -7 20 5 624 3 clay 55 0 <br /> 67.26 43.3 2 260 -6 80 5 219 3 clay 43 0 <br /> 67.42 35 2 1 350 -7 40 3 836 4 silty clay to clay 23 0 <br /> 59 30 0 0 820 -7 00 2.733 5 clayey silt to silty clay 15.0 <br /> 75 26.5 0 670 -6.80 2 528 6 sandy silt to clayey silt 11.0 <br /> 91 27 1 0 650 -6.70 2 398 6 sandy silt to clayey silt 10 0 <br /> 68.06 28.5 0 780 -6.60 2 736 5 clayey silt to salty clay 14.0 <br /> 68.24 30 4 0.900 -6.50 2.960 5 clayey silt to silty clay 15 0 <br /> 68.41 32 5 1 550 -6 20 4.768 4 silty clay to clay 21.0 <br /> 68.57 33.9 1 820 -5.90 5 366 4 silty clay to clay 23 0 <br /> 68.73 42 8 1.800 -3.40 4 210 4 silty clay to clay 25 0 <br /> 68.90 42 9 2 130 -2 50 4.969 3 clay 41.0 <br /> 69.06 43 6 2.460 -2.40 5.647 3 clay 42.0 <br /> 69.23 46 7 2.780 -3.30 5.959 3 clay 43.0 <br /> 69.39 44 7 2 770 -3 90 6.191 3 clay 44 0 <br /> 69.55 45.3 2 610 -3.80 5.756 3 clay 43 0 <br /> 69.72 44 3 2.490 -4.10 5.616 3 clay 43 0 <br /> 69.88 43 5 2.630 -3 90 6.040 3 clay 42.0 <br /> 70.05 42.8 2 760 -4.20 6 443 3 clay 40.0 <br /> 70.21 38 0 2.360 -4 90 6.206 3 clay 36 0 <br /> 70.37 31 9 1 890 -4. 90 5. 919 3 clay 32.0 <br /> 70 54 30.1 1 770 -4 50 5 874 3 clay 31 0 <br /> 70.70 34 6 2.220 -4.20 6 409 3 clay 33 0 <br /> 70.87 38 0 2 780 -4 90 7.310 3 clay 37.0 <br /> 71.03 42.8 3 280 -4.90 7.658 3 clay 44 0 <br /> 71.19 56 9 3.260 -6 90 5.729 3 clay 49.0 <br /> 71.36 54 2 2 740 -9 10 5 058 3 clay 49 0 <br /> 71.52 43.5 2 500 -9 70 5 752 3 clay 42 0 <br /> 71.69 34 8 1.960 -9.70 5.639 3 clay 37.0 <br /> 71.85 38.0 1 540 -9 60 4.057 3 clay 35 0 <br /> 72.01 36 0 1.810 -9.70 5.033 3 clay 33.0 <br /> 72.18 29 9 2 050 -7 50 6.858 3 clay 34 0 <br /> 0 34 40.5 2 180 -9 40 5 387 3 clay 38 0 <br /> 51 50.1 2.090 -10.10 4 .175 4 silty clay to clay 30.0 <br /> 72.67 51 3 1.840 -10 60 3.583 5 clayey silt to silty clay 24 0 <br /> 72.83 47.5 1 810 -11 40 3.808 5 clayey silt to silty clay 24.0 <br /> 73.00 49.3 2.140 -11 50 4.338 5 clayey salt to silty clay 25 0 <br /> 73.16 58 9 2 350 -11 70 3. 988 5 clayey silt to silty clay 26.0 <br /> 73 33 57.5 2 020 -12.00 3 511 5 clayey salt to silty clay 29 0 <br /> 73.49 65 8 2.290 -12.00 3.479 5 clayey silt to silty clay 28.0 <br /> 73.65 54.3 2 440 -12 10 4.491 5 clayey silt to salty clay 27 0 <br /> 73 82 51.5 1.650 -12.20 3.202 6 sandy silt to clayey silt 21 0 <br /> 73.98 61.0 0 900 -12 20 1 475 7 salty sand to sandy salt 19.0 <br /> 74 15 66.3 0 780 -12.30 1.176 7 salty sand to sandy salt 21 0 <br /> 74 .31 74 0 0.830 -12.30 1.121 7 silty sand to sandy silt 23.0 <br /> 74.48 78.0 1 090 -12 30 1 397 7 silty sand to sandy silt 25 0 <br /> 74 64 81.4 1 390 -10.80 1.707 7 silty sand to sandy silt 27.0 <br /> 74 .80 91.7 0.950 -11.20 1.036 8 sand to silty sand 21 0 <br /> 74 97 95.0 0 890 -11. 60 0.937 8 sand to silty sand 22.0 <br /> 75 13 93 2 1.160 -11.70 1.244 8 sand to silty sand 22.0 <br /> 75.30 90.3 1 160 -11 40 1.284 8 sand to silty sand 22 0 <br /> 75.46 89 4 1 150 -11.00 1.286 8 sand to salty sand` 21.0 <br /> 75 62 87.7 1.210 -11.00 1.379 7 silty sand to sandy silt 27 0 <br /> 75.79 78.2 1 150 -11.00 1 470 7 silty sand to sandy silt 25.0 <br /> 75 95 68.1 1.430 -11.40 2.099 7 silty sand to sandy silt 22 0 <br /> 76.12 63.3 1 860 -9.30 2 940 6 sandy silt to clayey salt 25.0 <br /> 76.28 67 1 1 480 -11.00 2.204 7 silty sand to sandy silt 23 0 <br /> 76.44 86.9 1.240 -11.70 1.426 7 silty sand to sandy silt 26.0 <br /> 76 61 86.3 1.930 11.80 2 236 6 sandy silt to clayey silt 35.0 <br />