Laserfiche WebLink
• 0 <br />Table 1 <br />Proposed Analytes and Approximate Number of Samples <br />Purpose <br />Analyte(s) <br />Method <br />Soil <br />Groundwater <br />Contaminant <br />Assessment <br />TPH-g & TPH-d <br />8015M <br />12 to 25 <br />12 to 25 <br />BTEX & MTBE <br />8060B <br />12 to 25 <br />12 to 25 <br />"Full suite" of VOCs including <br />1,2 -DCA and EDB <br />80606 <br />3 <br />3 to 6 <br />Remedial <br />Assessment <br />Metals <br />6000 and 7000 -series <br />0 <br />4 to 5 <br />Dissolved Gasses <br />SW3810 <br />0 <br />3 to 5 <br />Nitrate, Sulfate, Chloride <br />300.0 <br />0 <br />5 to 10 <br />Ferrous Fe <br />SM3500 Fed <br />0 <br />5 to 10 <br />Alkalinity <br />310.1 <br />0 <br />5 to 10 <br />Total organic carbon <br />Walkley-Black <br />3 to 5 <br />0 <br />Total organic carbon <br />415.2 <br />0 <br />3 to 5 <br />Numbers of samples are estimated. Actual numbers within the ranges given will depend upon uv1r results and <br />field indications of contamination, logistical aspects of sample collection, progress of field work with respect to <br />intended schedule, and other issues. <br />ZAsacDP120051Pd\88018800391 A.5ad.doc <br />Page 1 of 1 <br />