Organic Data Qualifiers <br /> A -- This qualifier indicates that a TIC is a suspected aldol-condensation product <br /> B -- This flag is used when the analyte is found in the associated blank as well as the <br /> sample This notation indicates possible blank_contamination and suggests that the <br /> data user evaluate these compounds and their amounts carefully <br /> C -- The "C" flag indicates the presence of this compound has been confirmed by the ' <br /> GC/MS analysis <br /> D — This qualifier is used for all the compounds identified in an analysis at a secondary <br /> dilution factor. "D" qualifiers are used only for the samples reported at more than one <br /> dilution factor <br /> E This flag indicates that the value reported exceeds the lmear calibration range for that ' <br /> compound Therefore, the sample should be reanalyzed at the appropriate dilution <br /> The "E" qualified amount is an estimated concentration, and the results of the dilution <br /> will be reported on a separate Form I <br /> I -- The qualifier indicates that the reporting limit to the "I" qualifier has been raised It <br /> is used when the chromatographic interference prohibits detection of a compound at a ' <br /> level below the concentration expressed on the Form 1. <br /> J -- Indicates an estimated value It is used when the data indicates the presence of a <br /> target compound below the reporting limit or the presence of a Tentatively Identified <br /> Compound (TIC) <br /> N -=-This= ualifierffdieates- resuti tive evidence of a com ound�Tliis fla is oni used ' <br /> ]� P p g Y <br /> for Tentatively Identified Compounds (TIC), where the identification-is-based on_a <br /> mass spectral library research It is applied to all TIC results For generic ' <br /> - _-- --- -- - - characterization of a TIC,-such as chlorinated hydrocarbon, the "N" qualifier is not -used <br /> P -- This qualifier is used for target analytes. when there is a eater than 40% difference <br /> Yt � <br /> for detected concentrations between the two columns or detectors The concentration <br /> value is reported on Form I and flagged with a"P" ' <br /> U -- Indicates the compound was analyzed for but not detected The number adjacent to <br /> the "U" qualifier indicates the reporting limit for that compou d. TI'ic reporting linnet <br /> can vary from sample to sample depending on dilution factors or percent moisture <br /> adjustments when indicated <br /> 0. <br /> 1 <br /> 0004 <br />