Laserfiche WebLink
J <br /> Sample Labeling and Handling <br /> Water samples were preserved in laboratory-cleaned, 40-milliliter glass vials that contained <br /> concentrated hydrochloric acid as a preservative The water samples were sealed with <br /> Teflon-lined lids to eliminate air bubbles The sample containers were labeled in the field <br /> with the site identification, monitoring well number and'depth, and date,-and promptly <br /> placed in iced storage for transport to the 'laboratory The geologist initiated <br /> chain-of-custody records in the field that accompanied the samples to a laboratory certified <br /> by the state of California for the analyses requested Samples were transported to the <br /> laboratory promptly Samples in our custody were properly disposed of after their useful life <br /> had expired ' <br /> Evaluating the Groundwater Flow Direction and Gradient ' <br /> The elevations and positions ("x" and "y" lateral coordinates) of the monitoring well were <br /> surveyed by a licensed land surveyor The elevations of the monitoring wells were ' <br /> referenced to withidO 01 foot of the bench mark The honzontal distances were measured <br /> to the nearest 01 foot The elevations were taken to either the notch or the arrow on the well <br /> casing <br /> The groundwater elevations for each monitoring well were calculated by subtracting the <br /> depth to water from the wellhead elevation The groundwater elevation information was to <br /> construct a potentiometric surface map, which was used to evaluate the direction of <br /> groundwater flow and the magnitude of the groundwater gradient <br /> 4 , f <br /> S <br /> S I <br /> CP\N 1CamPk\DatalArchrve\Rodgers\QtrlyIRDGR1g00 dor--98Vt 1 B-2 IT Corporatton <br />