Ta�
<br /> Treatment SystemFerformance Data •
<br /> The Transmission Shop
<br /> 515 West Charter Way
<br /> Stockton,California
<br /> Field TPH as Gasoline Benzene
<br /> FID Reading
<br /> Hour Meter Percent Blower Flow Rate Total System Influent Net Removed Influent Net Removed
<br /> Site Visit Reading Operational Vacuum at Manifold Flow Rate Influent Effluent Concentration Removed* to Date Concentration Removed* to Date
<br /> Date Description Comments (hours) N ("H2O) (scfm) (scfm) (ppmv) (ppmv) (mg/m3) (pounds) (pounds) (mg/m3) (pounds) (pounds)
<br /> 01/31/00 Sample/O&M Startup 2,373 NA NA NA 37 4,800 1,200 4,910 0 0 155 0 00
<br /> 02/03/00 Sample/O&M Startup 2,375 3 NA 12 15 2,000 800 4,690 1 1 <2 50 0 00
<br /> 03/08/00 Sample/O&M 2,851 58 76 NA 43 600 18 8,100 616 617 295 021 02
<br /> 03113!00 O&M System dawn-pending repair of heating coil and high temperature valve shall --- --- --- 0 617 --- 000 02
<br /> 04/21/00 O&M Repair/Restart 2,975 12 52 43 43 - --- --- 158 775 --- 130 15
<br /> 04/24/00 Sample/O&M 3,039 88 50 57 47 1,500 85 7,900 71 846 <2 50 003 15
<br /> 05/01/00 Sample/O&M 3,206 100 54 NA 53 700 8 4,650 156 1,002 <2 50 005 1 6
<br /> 06/05/00 Sample/O&M 3,717 61 28 36 31 3,000 800 4,810 160 1,162 <0 500 002 16
<br /> 07/10/00 Sample/O&M 4,150 52 75 52 43 300 50 504 184 1,346 <0160 006 17
<br /> 07/17/00 O&M KO tank full 4,178 17 --- --- - --- --- --- 0 1,346 --- 000 17
<br /> 07/24/00 O&M Unknown 4,199 12 92 76 72 5,000 3,000 --- 10 1,356 --- 001 17
<br /> 08/07/00 Sample/O&M KO tank full 4,229 9 68 61 55 2,500 1,800 3,180 25 1,381 171 001 17
<br /> 08/14/00 O&M KO tank full 4,397 100 80 69 42 350 55 -- 104 1,485 --- 004 17
<br /> 08/28/00 O&M 4,734 100 80 74 43 150 35 --- 215 1,701 - 008 1 8
<br /> 09/07/00 Sample/O&M KO tank full 4,759 10 60 55 49 3,000 1,500 4,800 13 1,714 <1 25 000 1 8
<br /> 09/11/00 O&M 4,856 101 60 57 45 3,200 1,200 --- 47 1,761 --- 001 18
<br /> 09/18/00 O&M 5,023 100 64 52 40 --- --- --- 73 1,835 --- 002 1 8
<br /> 10/04/00 Sample/O&M** 5,407 100 78 70 43 --- --- 1,020 49 1,884 <0 500 009 1 9
<br /> 10/09/00 O&M 5,527 100 78 63 44 900 400 --- 16 1,899 - 003 20
<br /> 10/16/00 O&M 5,695 100 78 61 56 100 25 --- 28 1,927 005 20
<br /> 10/25/00 O&M 5,911 100 68 63 55 100 60 --- 35 1,962 - 007 21
<br /> 10/30/00 O&M 5,938 22 System down due to no power in compound 0 1,962 000 21
<br /> 11/30/00 0&M 5,938 0 System down due to faded acuator valve 0 1,962 000 21
<br /> 12/04/00 O&M 5,938 0 64 --- 59 --- --- --- 0 1,962 --- 000 21
<br /> 12/13/00 Sample/O&M 6,154 100 70 58 62 --- --- 566 71 2,033 <2 50 013 22
<br /> 12/18/00 O&M 6,265 93 62 60 57 900 450 - 34 2,067 006 23
<br /> 01/04/01 Sample/O&M baked catalyst 6,674 100 42 48 46 >1000 >1000 2,260 96 2,162 26 009 24
<br /> 01/08/01 O&M 6,769 99 43 52 45 250 120 --- 22 2,185 --- 002 24
<br /> 01/15/01 O&M 6,936 100 50 52 45 250 110 --- 39 2,223 --- 004 24
<br /> 01/22/01 O&M 7,104 99 52 51 46 300 100 --- 39 2,262 --- 004 25
<br /> 01/29/01 O&M 7,192 52 43 49 43 310 90 --- 19 2,282 --- 002 25
<br /> 8800391 A1Svedata_3g011TABLE 1 Page 1 of 2 10/24/2001
<br />
|