My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0001196
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
515
>
2900 - Site Mitigation Program
>
PR0527799
>
ARCHIVED REPORTS XR0001196
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2019 7:49:34 PM
Creation date
3/4/2019 1:53:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0001196
RECORD_ID
PR0527799
PE
2960
FACILITY_ID
FA0018844
FACILITY_NAME
TRANSMISSION STORE
STREET_NUMBER
515
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
14707408
CURRENT_STATUS
01
SITE_LOCATION
515 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
83
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr John Benedict Project 880039 IA <br /> Apn1 19, 2001 <br /> Page 3 <br /> 23 8 gg/L, 5 64 µg/L, 12 3 µg/L, and 7 26 µg/L, respectively MTBE was below laboratory <br /> reporting limits Results of laboratory analyses are summarized in the Table 1 <br /> The results of the point monitoring were used to evaluate the groundwater gradient The gradient <br /> is approximately 0 003 foot per foot to the east-northeast (Figure 2) Groundwater analytical <br /> data for the subject site and for the former ARCO facility 2168 are also summarized on Figure 2 <br />' REMEDIATION SYSTEM STATUS: FIRST QUARTER 2001 <br />' The remediation system consists of four shallow zone and three deep zone SVE wells, from <br /> which soil vapors are extracted using a Stealth Bobcat Catalytic Oxidizer rated at 100 cubic feet <br /> per minute (cfm) Startup of the remediation system occurred on February 3, 2000, under the <br />' supervision of regulatory personnel Subsequently, IT staff perform weekly system operation <br /> and maintenance, collects influent and effluent air samples monthly in accordance with air board <br /> permit requirements, and reports quarterly to the air board <br /> Sampling Results <br /> During the first quarter 2001, soil vapor samples were collected from influent and effluent <br /> sample ports on January 4, February 5, and March 5, 2001 Vapor samples collected on January <br /> 4, 2001 were reported in the fourth quarter 2000 report The samples were submitted to <br /> Sequoia Analytical in Sacramento, California, a state-certified laboratory, for analysis of TPH-g <br /> and BTEX using USEPA Methods 8015 and 8020, respectively Influent TPH-g concentrations <br /> on February 5, 2001 and March 5, 2001 were reported to be 473 and 228 milligrams per cubic <br /> meter (mg/m'), respectively The corresponding effluent TPH-g concentrations were 50 4 and <br /> 18 4 mg/m3, respectively <br />' Benzene was not detected above the laboratory reporting lima, in the influent samples collected <br /> on February 5 and March 5, 2001, and in the effluent sample collected on February 5, 2001 <br /> Benzene was detected In the effluent sample collected on March 5, 2001 at a concentration of <br /> 0 0808 mg/m3 Laboratory analytical reports and chain-of-custody documentation are presented <br />' In Appendix D <br /> Operational Status <br /> The treatment system operational uptime was 87 percent during the first quarter 2001 Down <br />' time resulted from possible power interruptions on two occasions and high water levels in the <br /> treatment system moisture knockout pot To improve system destruction efficiency, on January <br /> 4, 2001, the catalyst was serviced and on February 5, 2001, the burn chamber temperature set- <br /> IT CORPORA TION <br /> SAC IN\rancfpllProjectsTrojects188010391iA\Quarterlysl1g01 doc-Mit 1 <br /> (01010000) <br />
The URL can be used to link to this page