Laserfiche WebLink
Q Sequoia 680 Chesapeake Drive Redwood City CA 94063 (415) 364 9600 FAX(415) 364 9233 <br /> 1900 Bates Avenue Swte L Concord CA 94520 (510) 686 9600 FAX (510) 686 9689 <br /> Analytical 819 Striker Avenue Suite 8 Sacramento CA 95834 (916) 921 9600 FAX(916)921 0100 <br /> Blaine Tech Services, Inc Client Project ID 940510-K1, Shell, 620 W Charter Wa Sampled May iQ, 1994 <br /> 985 Timothy Drive Sample Matrix Water Received May 11, 1994 <br /> San Jose, CA 95133 Analysis Method EPA 5030/8015 Mod /8020 Reported May 23, 1994 <br /> Attention Jim Keller First Sample # 4E74601 <br /> TOTAL PURGEABLE PETROLEUM HYDROCARBONS With BTEX DISTINCTION <br /> Reporting Sample Sample Sample Sample Sample Sample <br /> Analyte Limit I D I D. I D I D I D I.D <br /> lig/L 4E74801 4E74802 4E74803 4E74804 4E74805 4E74806 <br /> MW-1 MW-2 MW-3 MW-4 MW-5 MW-6 <br /> Purgeable <br /> Hydrocarbons 50 N D 70,000 N D 15,000 N D N D <br /> Benzene 050 N D 1,400 N D 170 N D N D <br /> Toluene 050 N D 1,100 N D 140 N D N D <br /> Ethyl Benzene 050 N D 1,500 N D 200 N D N D <br /> Total Xylenes 050 N D 12,000 N D 1,400 N D N D <br /> Chromatogram Pattern -- C6-C12 - C6-C12 - -- <br /> Quality Control Data <br /> Report Limit Multiplication Factor 1 0 200 1 0 20 10 1 0 <br /> Date Analyzed 5/15/94 5/15/94 5/16/94 5/15/94 5/17/94 5/15/94 <br /> Instrument Identification GCHP-2 GCHP-2 GCHP-17 GCHP-2 GCHP-17 GCHP-2 <br /> Surrogate Recovery, % 96 103 101 108 101 101 <br /> (GSC Limits = 70-130%) <br /> Purgeable Hydrocarbons are quantitated against a fresh gasoline standard <br /> Analytes reported as N D were not detected above the stated reporting limit <br /> &EQUOIA ANALYTICAL <br /> Suzanne Chin <br /> Project Manager 4E74801 SLA `t' <br />