1810
>
2300 - Underground Storage Tank Program
>
PR0231141
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2022 10:35:03 AM
Creation date
3/5/2019 8:58:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231141
PE
2361
FACILITY_ID
FA0003954
FACILITY_NAME
SJ CO PUBLIC WORKS CORP YARD*
STREET_NUMBER
1810
Direction
E
STREET_NAME
HAZELTON
STREET_TYPE
AVE
City
STOCKTON
Zip
95205
APN
15518002
CURRENT_STATUS
01
SITE_LOCATION
1810 E HAZELTON AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OPW 1 m2200 Series Thread -On Single Wall Grade Level Spill <br /> R E T A I L F U E L I N G Containers with Replaceable Bellows <br /> A WMMW <br /> lwgtallation and Maintenance Instructions <br /> Please read these warnings and assembly instructions com PRODUCT . , . . , <br /> NTY PERIOD <br /> pletely and carefully before starting . Failure to do so may <br /> cause product failure, or result in environmental contami - FlexWorks Primary Pipe 10 years from date of manufacture <br /> nation due to liquid leakage into the soil, creating hazard All Products and re- 1 year from date of installation <br /> ous spill conditions , placement parts in - (proof of purchase from certified <br /> IMPORTANT: The OPW 1 -2200 Spill Container is preassem - stalled in the State of contractors/technicians required) <br /> bled for your convenience and ease of installation . Check to California OPW warrants ongoing compliance <br /> make sure the unit is intact and undamaged and all parts Certified to California with the standards and specifica- <br /> have been supplied . Never substitute parts for those sup- CP-201 and/or CP- 206 tions for the duration of the warran - <br /> plied . Doing so may cause product failure . Standards* ty period required by the State of <br /> WARNING - DANGER: Using electrically operated equip - California; this limited warranty is <br /> ment near gasoline or gasoline vapors may result in a fire or under the condition the equipment <br /> explosion , causing was installed and maintained by <br /> p g personal injury and property damage. Be / <br /> trained and certified contractors <br /> sure that the working area is free from such hazards, and technicians unless noted in Installa- <br /> tion <br /> use proper precautions . tion Manual . <br /> NOTE: Keep the riser pipe capped at all times when prod- All other Products and 1 year from date of manufacture** <br /> uct is in the storage tank, so the vapors cannot escape into replacement parts <br /> the environment. <br /> floUce: OPW products must be used in compliance with *Products certified to California CP-201 and/or CP -206 Stand - <br /> applicable federal, state, and local laws and regulations . ards have been factory tested and met all applicable perfor- <br /> Product selection should be based on physical specifica- mance standards and specifications and will have an OPW <br /> tions and limitations and compatibility with the environ - registration card enclosed/attached to the product . <br /> ment and material to be handled . All illustrations and spec- OPW's exclusive obligation under this limited warranty is, at <br /> ifications in this literature are based on the latest produc- its option, to repair, replace or issue credit (in an amount not <br /> tion information available at the time of publication . Prices, to exceed the list price for the product) for future orders for <br /> materials, and specification are subject to change at any an product that may <br /> time, and models may be discontinued at any time, in either y p y prove defective within the applicable <br /> case, without notice or obligation . warranty period . (Parts repaired or replaced under warranty <br /> are subject to prorated warranty coverage for remainder of <br /> OPW STANDARD PRODUCT WARRANTY TAG the original warranty period) . Complete and proper warranty <br /> Notice : FlexWorks by OPW, Inc., VAPORSAVER'' and all other claim documentation and proof of purchase required . All <br /> OPW products must be used in compliance with all applicable warranty claims must be made in writing and delivered dur- <br /> federal, state, provincial and local laws, rules and regulations . ing the applicable warranty period to OPW at OPW 9393 <br /> Product selection is the sole responsibility of the customer Princeton -Glendale Road Hamilton, Ohio, USA 45011 , Atten - <br /> and/or its agents and must be based on physical specifica - tion : Customer Service Manager. No products may be re - <br /> tions and limitations, compatibility with the environment and <br /> turned to OPW without its prior written authority, <br /> material to be handled . All illustrations and specifications in This limited warranty shall not apply to any FlexWorks or VA- <br /> this literature are based on the latest production information PORSAVERTM product unless it is installed by an OPW attested <br /> available at the time of publication . Prices, materials and installer and all required site and warranty registration forms <br /> specifications are subject to change at any time, and models are completed and received by OPW within 60 days of instal- <br /> may be discontinued at any time, in either case, without no - lation . This limited warranty also shall not apply to any Flex- <br /> tice or obligation . Works, VAPORSAVERTM' or other OPW product: unless all pip - <br /> ing connections are installed with a nationally-recognized or <br /> OPW warrants solely to its customer (the initial purchaser and state-approved leak detection device in each tank and dis- <br /> anysubsequent purchasers within the warranty period) that penser sump (which are not for storage and from which all <br /> the following products sold by OPW will be free from defects i discharge hydrocarbons must be removed, and the systems <br /> tionsand workmanship under normal use and condi - completely cleaned, within 24 hours); unless testable sumps <br /> tons for the periods indicated : utilize FlexWorks pipe and access fittings; unless a sump in - <br /> spection log or an EPA recommended/required checklist is <br /> maintained and the results are furnished to OPW upon re- <br /> quest; and unless OPW is notified within 24 hours of any <br /> known or suspected product failure and is provided with un- <br />
The URL can be used to link to this page
Your browser does not support the video tag.