Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> SPILL CONTAINER TESTING REPORT FORM (Page 1 of 1 ) <br /> Type of Action ❑ Installation Test ❑ Repair Test E 12 Month Test <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Spill Container Test <br /> 10181545 4/ 11 / 19 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> BAGLEY- SAN JOAQUIN COUNTY CORP YARD <br /> Business Site Address City ZIP Code <br /> 1810 E . HAZELTON AVE STOCKTON 95205 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test (Print as shown on the /CC Certification) Phone # <br /> Edward Stearns (209 ) 744 -0112 <br /> Contractor / Tank Tester License ; ICC Certification # ICC Certification Expiration Date <br /> 14- 1760 Ex . 9/30/20 888308MT 11 /9/2020 <br /> Spill Container Testing Training and Certifications (List applicable certifications.) <br /> Franklin Fueling - EBW & Phil Tite # 1009893708 Ex . 11 /29/2020 t , . .�, <br /> OPW # 104-635 Ex . 3/ 14/2020 " <br /> III . SPILL CONTAINER TESTING INFORMATION a <br /> Test Method Used : ❑x Manufacturer Guidelines (Specify) : LAKE TEST <br /> ❑ Industry Code or Engineering Standard (Specify) : <br /> ❑ Engineered Method (Specify) : M1 V1 iC% V !\; I AL H � I I <br /> Attach the testing procedures and all documentation required to determine the results. # of Attached Pages <br /> i <br /> TANK ID : (By tank number, stored product, etc) DIESEL <br /> Spill Container Manufacturer: OPW <br /> Method of Cathodic Protection: ❑x Non- Metallic N Non-Metallic 9 Non-Metallic ❑ Non-Metallic <br /> j ❑ Isolation ❑ Isolation ❑ Isolation ❑ Isolation <br /> ❑ Other (Specify in V.) ❑ Other (Specify in V.) ❑ Other (Specify in V) ❑ Other (Specify in V.) <br /> Inside Diameter of Spill Container: (Inches) 11 <br /> Depth of Spill Container: (Inches) 15 <br /> Does the spill container have a 5 gallon capacity? R Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No LDrain <br /> ❑ No <br /> Method to Keep Spill Container Empty: ❑x Drain Valve ❑ Drain Valve ❑ Drain Valve❑ Onsite Pump ❑ Onsite Pump ❑ Onsite Pump pOther (SpecifyinV) ❑ Other (Specify in V) ❑ Other (Specify in V) ify in V.) <br /> IV. SUMMARY OF TESTING RESULTS <br /> Spill Container Test Results : L 9 Pass El Fail El Pass ❑ Fail ❑ Pass El Fail ❑ Pass ❑ Fail <br /> V. COMMENTS <br /> Any items marked "Fail' above must be explained in this section. Any additional comments may also be provided here . <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the spill containers were tested in accordance with California Code of Regulations , Title 23, Division 3, <br /> Chapter 16 , Section 2637 . 1 and all the information contained herein is accurate . <br /> UST Service Technician Signature n <br /> "o facility has more components than this form accommodates, additional copies of this page may be attached. <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = International Code Coundl <br />