aft unit requirements continued; <br /> 3642-1-0 <br /> ge 2 <br /> 12. The soil remediation system shall not be operated unless the combustion chamber is at or above the <br /> minimum operating temperature. The system shall automatically terminate operation if the temperature drops <br /> below the minimum operating temperature [District Rule 2201 <br /> 13. The minimum operating temperature for the Combustion chamber of the thermal oxidizer shall be 1400 <br /> degrees F [District Rule 2201] <br /> 14. The total VOC emission rate from the soil remediation system served by the thermal oxidizer shall not <br /> exceed 12 6 pounds in any one day [Distract Rule 2201] <br /> 15 Only natural gas shall be used as auxiliary fuel for the combustion of VOC. (Distnct Rule 2201] <br /> 16. The total NOx emission rate from the soil remediation system Served by the thermal oxidizer shall not <br /> exceed 0.1 lb/MMBTU [Distnct Rule 2201] <br /> 17. The total CO emission rate from the soil remediation system served by the thermal oxtdi7er shall not <br /> exceed 0.021 lb/NIMBFU [District Rule 22011 <br /> 1 hese ternis and conditions are part of the 1 4,i1to-wide Permit to Operate. <br />