Laserfiche WebLink
Sart ,roaguxn Valley Unified <br /> ,Air Pollution Control District <br /> PERMff UNIT: N-3642-1-0 EXPIRATION DATE: 06/01/2002 <br /> EQUIPWNT DESCRIPTION: <br /> SOIL VAPOR EXTRACTION AND REMEDIATION OPERATION SERVED BY A BURNERS & <br /> CONTROLS, INC. (MODEL # 200T/0) 400 KBTU/HR THERMAL OXIDIZER. <br /> Perinit Unit Requirements <br /> 1. No air contaminant shall be discharged into the atmosphere for a period or periods a gregat€ng more than <br /> three minutes in any one hour which is as dark as, or darker than, Ringelmann 1 or 20 1 opacity [District <br /> Rule 4101] <br /> 2. No air contaminant shall be released into the atmosphere which causes a public nuisance [Dist,,et Rule <br /> 4102] <br /> 3. The soil remediation project shall be maintained in proper operating condition at all times [District Rule <br /> 1201] <br /> 4. Either the VOC control efficiency shall not be less than 95 %, or the total. VOC emission rate shall not <br /> exceed 2 pounds in any one day [District Rule 220t] <br /> amplung ports adequate for extraction of grab samples, measurement of gas flow rate, and use of an <br /> Vii", PIID, or other District-approved VOC detection device shall be provided for both the influent and the <br /> effluent gas streams [District Rule 10811 <br /> 6 Ongoing compliance with VOC emission rate and control efficiency requirements shall be demonstrated by <br /> sampling both the influent and the effluent gas streams with a FID, PID, or other District-approved VOC <br /> detection device [District Rule 10811 <br /> 7. SampW?g to demonstrate ongoing compliance shall be performed at least once per month when utilizing <br /> the thermal oxidizer unit, [District Rule 1081] <br /> 8 Records of the cumulative running time and the measured influent and effluent VOC concentrations shall <br /> be maintained. [District Rule 22011 <br /> 9. All records shall be retained for a minimum of 2 years, and shall be made available for District <br /> inspection upon request [Distnct Rule 10 70] <br /> 10. Operation of the soil remediation system shall be terminated on or before 18 June 1999 unless, prior to <br /> this date, approval is granted by the District to extend the project [District Rule 2201] <br /> 11 The oxidizer shall be equipped and operated with a gauge which indicates the temperature of the <br /> (ombustion chamber. A continuous recording device shall be utilized to document the combustion chamber <br /> temperature during system operation (District Rule 22011 <br /> Permit unit requirements continue on next pine <br /> These terms and conditions are part of the facility-vide P'erntit to Operate. <br /> Ac-ILTrY NAME DARFETRO <br /> UWATION 749 E CHARTER WY, STOCKTON <br />