ARCHIVED REPORTS XR0010716
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
749
>
3500 - Local Oversight Program
>
PR0544218
>
ARCHIVED REPORTS XR0010716
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2019 11:55:34 AM
Creation date
3/5/2019 10:56:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0010716
RECORD_ID
PR0544218
PE
3526
FACILITY_ID
FA0003870
FACILITY_NAME
SRH FOOD & GAS
STREET_NUMBER
749
Direction
E
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
14734309
CURRENT_STATUS
02
SITE_LOCATION
749 E DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�i <br /> Since CGG has contracted with Del-Tech to do the quarterly monitoring at this site we are <br />' °7 submitting the SOP's of Del-Tech to be reviewed by the EHD San Joaquin County CGG <br /> feels that the SOP's of Del-Tech meet the requirements of sampling monitoring wells By <br /> June 21,2004 we will submit an up dated copy of our QA/QC Del-Tech at our request will <br /> Ibe using the Dedicated Waterra Pump to purge the wells <br /> It is the policy of CGG to notify the county at least 48 hours prior to a quarterly sampling, if <br /> this was not done for the January 2004 monitoring event, we apologize <br /> As president of California Geophysical Group, Inc , I have never instructed any technician <br /> that the equipment did not need to be decontaminated for sampling any well <br /> The next quarterly monitoring event will take place in July 2004, all monitoring wells on <br /> and off site will be sampled All laboratory samples will be tested for TPH-G, BTEX, by <br />' method EPA 602, Oxygenates, 1-2 DCA and EDB by method EPA 8260 Quarterly <br /> sampling of all wells and laboratory tests will continue until otherwise directed by the EHD, <br /> San Joaquin County We will be on site to oversee this next monitoring event <br />' We are now using MW instead of BM for the monitoring well labels The numbers for the <br /> wells will remain the same You will notice in this Quarterly Report that we have <br /> implemented this change <br />' The groundwater in wells MWA, MW-5, MW-6, MW-7, MW-8, and MW-9 were above <br /> California Drinking Water Standards for benzene The benzene plume appears to be <br />' flowing around this site from the two contaminated sites, west of this site The wells which <br /> had TPH are MWA, MW-2, MW-5 MW-6, MW-7, MW-8 and MW-9 All of the figures <br /> indicate that water is entering this site from a source to the east of this site This can be <br /> seen by looking at the contouring around well MWA where water is definitely entering the <br /> site from Charter Way See Figures 2 and 3 <br /> The contamination from this site is TPH and chemicals related to gasoline MtBE was <br />' recorded in wells MW-1, MW-2, MW-3, MW-7, MW-8, MW-9 and MWA 1 This anomaly <br /> is the same as reported for Benzene and TPH <br /> Monitoring well MW-8 was sampled this quarter with a bailer and pump, at the request of <br /> the EHD regulator <br /> Dissolved oxygen levels were recorded this quarter at this site The levels were <br />' measured with a calibrated YSI model 51 B meter by placing the sensor 5 feet below the <br /> surface of the water table after the bailing of the wells The measured levels are shown <br />' on Table 3A and Figure 5 <br /> Conclusions <br />' We will continue to monitor this site The next monitoring event will take place in July <br /> 2004 <br />' Attached please find the Hazardous Waste Manifest showing the purged ground water <br /> •� has been removed properly <br />