<br /> December 1, 2009
<br /> Frank Morita Rashad Hussain
<br /> 6622 Belmont Place 814 E. Charter Way
<br /> Stockton, CA 95207 Stockton, CA 95206
<br /> Subject: Former Morita Brothers Site Code: 1061
<br /> 814 E. Charter Way
<br /> Stockton, CA
<br /> The San Joaquin County Environmental Health Department (EHD) has requested and received
<br /> concurrence with a "no further action required" (closure) determination from the Central Valley
<br /> Regional Water Quality Control Board. This is to notify you that Section 25297.15 (a) in Chapter
<br /> 6.7 of the Health and Safety Code includes a requirement that EHD (local agency) not issue a
<br /> closure letter, or make a determination that no further action is required with respect to
<br /> "hazardous substance" underground storage tank release sites unless all current record owners
<br /> of fee title to the site have been notified of the proposed action by the primary or active
<br /> responsible party.
<br /> Please provide EHD certification in writing that all record fee title owners have been notified of
<br /> the request for closure. If you are the sole property owner, provide a statement of that fact to
<br /> EHD, to fulfill this requirement (form enclosed).
<br /> In addition, prior to a closure/no further action required letter being provided to you, the
<br /> monitoring wells installed during the site investigation must be destroyed under EHD permit and
<br /> inspection. After reviewing the data on these wells, MWA, MW-6, MW-7, MW-106, MW-107,.
<br /> MW-108, MW-109, MW-208 and MW-209 must have the well contents removed, typically
<br /> through drilling them out, and grouted. Wells MW-2, MW-4, MW-5, MWA 1, MWA 04, MWA 10,
<br /> MWA 11, MW-202 and MW-210 can be pressure grouted with the required below surface cut off
<br /> and mushroom cap as stated in the San Joaquin County Well Standards. Any deviations from
<br /> the well standards must be justified. Please have your consultant or a C-57 licensed driller,
<br /> submit two EHD permit applications and $405 permit and inspection fees per permit (total of
<br /> $810). If you have any questions, please contact Nuel Henderson at(209)468-3436.