' Geofog Fuua[Tecncs Inc Page 5 <br /> Groundwater Monitoring Report <br /> Project No 724 2 <br /> August 20,2001 <br /> 1 <br /> As indicated in Figure 4- MW-2 TPH-G vs GW Elevation, with the exception of June 20, <br />' 1997, contaminant concentrations have been stable in down gradient well MW-2 <br /> Oxidation/Reduction Potential (ORP) measurements (Table 5) corroborate the lab analysis <br /> and show that only wells MW-5, MW-6 & MW-7 have normal ORP The negative ORP <br /> values observed in the rest of the wells show that they are either within the core of the <br /> contamination plume or are in the reaction/depletion shadow down gradient of the plume <br /> 3.0 RECOMMENDATIONS <br /> GTI makes the following recommendations <br />' • Continue monitoring for one more quarter to determine contaminant trends <br /> • Perform fate and transport modeling to determine risk to off site receptors <br /> 4.0 LIMITATIONS <br /> This report was prepared in accordance with the accepted standards and practices of the <br /> field of environmental geology, groundwater hydrology and good business practices It <br />' should be recognized that definition and evaluation of environmental conditions is a <br /> difficult and an inexact science Judgments leading to conclusions and recommendations <br /> are generally made with an incomplete knowledge of the site-specific conditions present <br /> ' The tasks proposed and completed during this project were reviewed and approved by the <br /> local regulatory agency for compliance with the law No warranty, expressed or implied, is <br /> ' made <br /> i <br />