My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE HISTORY
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1033
>
3500 - Local Oversight Program
>
PR0544230
>
SITE HISTORY
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2019 8:27:46 PM
Creation date
3/5/2019 3:50:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE HISTORY
RECORD_ID
PR0544230
PE
3528
FACILITY_ID
FA0003829
FACILITY_NAME
VANCO TRUCK-AUTO PLAZA
STREET_NUMBER
1033
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16323041
CURRENT_STATUS
02
SITE_LOCATION
1033 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
: .4EMD PROGRAM CONSOLIDATED FC;'. `r -05 <br /> L/ TANKS <br /> UNDERGROUND STORAGE T -- TANK E 1 <br /> (two pages per tan] <br /> k) <br /> or <br /> TYPE OF ACTION ❑I NEW SITE PERMIT M 4 AMENDED PERMIT ❑ 5 CHANGE O INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check one item only) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Specify reason--for local use only) (Specify reaso -for local use only) ❑ STANK REMOVED 430 <br /> BUSINESS NAME(Sazne as FACILITY NAME or DBA--Doing Business As) <br /> Van De Pol Enterprises <br /> LOCATION WITHIN SITE(Optional) 431 <br /> Northwest side of site <br /> I.TANK DESCRIPTION (A scaled plot plan with the location of the UST system incl ding buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 1 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes ® No 434 <br /> UNKNOWN /s V3 -5 2 el UINKNOWN If"Yes",complete one page for each compartment. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436,- NUMBER OF COMPARTMENTS 437 <br /> 1988 Lal oCO 1 <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> II.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> 3_4. MOTOR VEHICLE FUEL ❑ la. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (If marked complete Petroleum Type) ❑lb. PREMIUM UNLEADED U4. DIESEL [ 6. AVIATION FUEL <br /> ❑2. NON-FUEL PETROLEUM ❑Ic. MIDGRADE UNLEADED [14. GASOHOL ❑99.OTHER <br /> ❑3. CHEMICAL PRODUCT COMMON NAME (From Hasardom Materials Inventory page) 441 CAS#(from Hazardous Materials Inventory page) 44'- <br /> [14. HAZARDOUS WASTE UNKNOWN <br /> (Includes Used oil) <br /> ❑95.UNKNOWN <br /> II1. TANK CONSTRUCTION <br /> TYPE OF TANK ❑I. SINGLE WALL ❑3. SINGLE WALL WITH ❑5. SINGLE WALT.WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EX'T'ERIOR MEMBRANE LINE P ❑95. UNKNOWN <br /> ®2. DOUBLE WALL ❑4. SIGNLE WALL IN VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank ❑ 1. BARE STEEL 03. FIBERGLASS/PLASTIC ❑S. CONCRETE ❑95. UNKNOWN 444 <br /> (Check one item only) [32. SrAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLAS ❑6. FRP COMPTIBLE Wil 00%METHANOL ❑99.OTHER <br /> REINFORCED PLASTIC FRP <br /> TANK MATERIAL-secondary tank [13. BARE STEEL ®3. FIBERGLASS I PLASTIC ❑5. CONCRETE ❑95. UNKNOWN 445 <br /> (Check one item only) Cl 2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGL SS C:18. FRP COMPTIBLE W/100%METHANOL ❑99.OTHER <br /> REINFORCED PLASTIC(FBP) ❑10.COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING ❑I.RUBBER LINED ❑3.EPDXY LINING ❑5.GLASS LINING Cl 95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING [1 4 PHENOLIC LINING ®6 UNLINED ❑99 OTHER <br /> (For local use only) <br /> (Check one item only) <br /> 449 DATE INSTALLED 449 <br /> OTHER CORROSION ❑ I MANUFACTURED CATHODIC ❑3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN <br /> PROTECTION IF APPLICABLE PROTECTION ❑4 IMPRESSED CURRENT ❑99 OTHER <br /> (Check one item only) ❑2 SACRIFICIAL ANODE (For local use only} <br /> SPILL AND OVERFILL YEAR INSTALLED 450 TYPE(local use only) ast OVERFILL PROTECTION EQU[PMENT:YEAR INSTALLED 452 <br /> (Check all that apply) ® 1 SPILL CONTAINMENT 2003 ® 1 ALARM 2003 ❑3 FILL TUBE SHUT OFF VALVE <br /> 212 DROP TUBE 2003 ®2 BALL FLOAT 2003 ❑4 EXEMPT <br /> ®3 STRIKER PLATE 1988 <br /> IV.TANK LEAK DETECTION(A description of the monit ring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Check all that apply) 453 IF DOUB LE WALL TANK OR TANK WITH BLADDER 454 <br /> (Check one item only) <br /> ❑I VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MT(:) ❑ I VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> (SIR) BIENNIAL TANK TESTING ❑99 OTHER <br /> I.V.TANK CLOSURE INFORMATION/PERI HENT CLOSURE 1N PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBST NCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> gallon ❑Yes ❑ No <br /> UPCF(12199 revised) 10 Formerly SWRCB Farm B <br />
The URL can be used to link to this page
Your browser does not support the video tag.