Laserfiche WebLink
UN r'IED PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 <br /> (Two pages per tank) <br /> Page I of 2 <br /> TYPE OF ACTION ❑ 1.NEW PERMIT ❑ 4.AMENDED PERMIT ® 5.CHANGE OF INFORMATION ❑ 6.TEMPORARY TANK CLOSURE 430. <br /> (Check one item only) ❑ 3.RENEWAL PERMIT ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (Specify reason) (Specify reason) ❑ 8.TANK REMOVED <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY ID: l <br /> ARCO Facility No.#5469 <br /> LOCATION WITHIN SITE(Optional) 431 <br /> I.TANK DESCRIPTION <br /> (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes ® No 434. <br /> PREMIUM#3 Owens Coming If"Yes,"complete one page for each compartment. <br /> DATE INSTALLED 435. TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS <br /> (YEAR/MO) 437 <br /> 12,000 <br /> ADDITIONAL DESCRIPTION(For local use only) Q39 <br /> II.TANK CONTENTS <br /> TANK USE 439. PETROLEUM TYPE <br /> 440, <br /> N 1. MOTOR VEHICLE FUEL ❑la. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (If checked,complete Petroleum Type) ®1b. PREMIUM UNLEADED [13. DIESEL [16. AVIATION GAS <br /> ❑ 2. NON-FUEL PETROLEUM ❑1 c. MIDGRADE UNLEADED [14. GASOHOL ❑99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materials Inventory page) 441. CAS#(from Hazardous Materials Inventory page) 442_ <br /> ❑ 4. HAZARDOUS WASTE Gasoline 8006-61-9 <br /> (Includes Used Oil) <br /> UNKNOWN <br /> 111.TANK CONSTRUCTION <br /> TYPE OF TANK [11. SINGLE WALL E-13. SINGLE WALL WITH EXTERIOR ❑5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br /> (Check one item only) MEMBRANE LINER ❑95. UNKNOWN <br /> ®2. DOUBLE WALL ❑4. SINGLE WALL IN A VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank ❑1. BARE STEEL 03. FIBERGLASS/PLASTIC ❑5. CONCRETE ❑95.UNKNOWN 444. <br /> (Check one item only) ❑2. STAINLESS STEEL [14. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE ❑99.OTHER: <br /> REINFORCED PLASTIC FRP W/100%METHANOL <br /> TANK MATERIAL-secondary tank ❑1. BARE STEEL ®3. FIBERGLASS/PLASTIC ❑8. FRP COMPTIBLE W/100%METHANOL [195.UNKNOWN 445. <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑9. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑ 10. COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING 0 1.RUBBER LINED ❑3.EPDXY LINING ❑5.GLASS LINING ❑95.UNKNOWN 446. DATE INSTALLED 447 <br /> OR COATING [12.ALKYD LINING [14.PHENOLIC LINING ®6.UNLINED ❑99.OTHER <br /> Check one item only) <br /> OTHER CORROSION ❑1.MANUFACTURED CATHODIC [13.FIBERGLASS REINFORCED PLASTIC ❑95.UNKNOWN 448. DATE INSTALLED 449, <br /> PROTECTION PROTECTION ❑4.IMPRESSED CURRENT [199.OTHER <br /> If Applicable) ❑2.SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEAR INSTALLED 450, TYPE 451 OVERFILL PROTECTION EQUIPMENT: YEAR INSTALLED 452. <br /> (Check all that apply) ®1.SPILL CONTAINMENT 2004 _OPW ®1.ALARM ❑3.FILL TUBE SHUT OFF VALVE <br /> ®2.DROP TUBE 2004 OPW ®2.BALL FLOAT ❑4.EXEMPT <br /> ®3.STRIKER PLATE 1990 <br /> IV.TANK LEAK DETECTION <br /> (A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK 453, IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br /> (Check all that apply) (Check one item only) <br /> ❑1. VISUAL(EXPOSED PORTION ONLY) ❑5.MANUAL TANK GAUGING(MTG) ❑I.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2. AUTOMATIC TANK GAUGING(ATG) ❑6.VADOSE ZONE ®2.CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3.CONTINUOUS ATG ❑7.GROUNDWATER ❑3.MANUAL MONITORING <br /> ❑4. STATISTICAL INVENTORY RECONCILIATION ❑8.TANK TESTING <br /> (SIR)+BIENNIAL TANK TESTING ❑99. OTHER <br /> V.TANK CLOSURE INFORMATION/ PERMANENT CLOSURE IN PLACE <br /> COATED DATE LAST USED(YR/MO/DAY) 455. ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 1 TANK FILLED WITH INERT MATERIAL? 457 <br /> gallons ❑Yes ❑ No <br /> UPCF hwfwrc-b(1/99)-114 http://www.unidocs.org Rev.02/16/00 <br />