SANJ O 1` Q U I `IA,II, Environmental Health Department <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> MUNN &PERKINS 26292 E RIVER RD, ESCALON March 05, 2019 <br /> Other Violations <br /> 4050 See below Unlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 711 CFR 112.8(c)(6)Failed to perform scheduled tank tests or inspections by appropriately qualified personnel. <br /> The 7,000 gallon tank containing SS-1 was not tested per the schedule in the SPCC plan. The SPCC plan states the <br /> the tanks are to be inspected/tested by a certified SP-001 certified inspector every 20 years.The SPCC plan <br /> describes the 7,000 gallon tank as being installed in 1984. Each aboveground container shall be tested and <br /> inspected for integrity on a regular schedule and whenever repairs are made. The qualifications of personnel <br /> performing tests and inspections,frequency and type of testing and inspections that take into account container <br /> size, configuration, and design shall be determined in accordance with industry standards. Examples of these <br /> integrity tests include, but are not limited to:visual inspection, hydrostatic testing, radiographic testing, ultrasonic <br /> testing, acoustic emissions testing, or other systems of non-destructive testing. Comparison records and other <br /> records of inspections and tests must be maintained on site. Immediately conduct the necessary testing and submit <br /> a copy of the test results to the EHD, or provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by April 4, 2019 . <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an <br /> appointment, please call (209)468-3420. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: March 05, 2019 Inspector: Inspector Phone: <br /> Printed Name and Title: CESAR RUVALCABA, REHS (209)953-6213 <br /> ramon lopez, Foreman <br /> FA0009335 PR0516200 SCO01 03/05/2019 <br /> EHD 28-01 Rev.09/27/2018 Page 4 of 4 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />