My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0001044
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1245
>
3500 - Local Oversight Program
>
PR0544236
>
ARCHIVED REPORTS XR0001044
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2019 7:34:42 PM
Creation date
3/6/2019 4:20:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0001044
RECORD_ID
PR0544236
PE
3526
FACILITY_ID
FA0024238
FACILITY_NAME
JM EQUIPMENT COMPANY
STREET_NUMBER
1245
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16323034
CURRENT_STATUS
02
SITE_LOCATION
1245 W CHARTER WAY
P_LOCATION
01
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C404wa!Technxs 144 <br /> S, Page 3 <br /> 1 Quarter 2004 Groundwater Monitoring Report <br /> Project No 507 2 <br /> May 19,2004 <br /> 1 <br /> Figure 2 shows the location of the well cluster used for calculating the vertical groundwater <br /> ' gradient in this report, MW-9 and MW-109 Table 1 shows Summary of Water Level and <br /> Gradients Slope and Bearing, and Table 2 shows the calculated vertical gradients The <br /> information used in the calculations is shown below <br /> ' Vertical <br /> gradient calculation formulas are as follows <br /> ' • Vertical correction for gradient [(gw gradient slope) x (distance) = vertical correction] <br /> 0 Vertical head [(head of deep well) - (head of shallow+ correction) = vertical head] <br /> • Vertical gradient ((vertical head)/ (vertical distance) = vertical gradient] <br /> For the March 2004 monitoring event a verticalradient was calculated ed for the MW-9/MW- <br /> 109 pair The vertical gradient was negative (a downward direction) at 0 001 ft/ft and <br /> ' approximately 0 4 the magnitude of the horizontal gradient of the water table (0 003) <br /> 1.2 Groundwater Sampling Procedure <br /> ' On March <br /> 19, 2003, Don Light of Del-Tech mobilized to the site to conduct groundwater <br /> M monitoring of the site's eleven monitoring wells Before sampling was attempted, the wells <br /> were sounded for depth to water and then a clear disposable bailer was used to determine if <br /> floating product was present No free product was noted for this event The wells were <br /> purged of at least three well volumes of stagnant water using a dedicated Waterra check-ball <br /> assembly and '/2 inch tubing or centrifugal pump Purging continued until the temperatuie, <br /> conductivity, and pH of the groundwater stabilized (<10% variation in three consecutive <br /> ' readings), indicating that formation water representative of aquifer conditions was entering <br /> the wells These water quality parameters were measured at intervals of each well volume <br /> purged <br /> ' Once purging was complete, a water sample was collected from the W <br /> p aterra tube Care was <br /> taken to minimize sample agitation Once the sample container was filled and capped, the <br /> ' bottle was inverted, tapped and checked for headspace bubbles The sample container was <br /> identified and labeled with a unique designation, inserted into a foam holder and placed into <br />' an ice chest cooled to 4°C for transport to the laboratory <br /> All non-disposable sampling equipment was decontaminated using a hot water washer and <br />' detergent before and between uses Disposable gloves were used by the technician to <br /> collect all samples and were changed with each sample collection <br />' A chain of custody document, listing all samples collected, accompanied the samples from <br /> field to laboratory, thereby providing a means to track the movement of and insure the <br /> integrity of the samples <br />
The URL can be used to link to this page
Your browser does not support the video tag.