My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1313
>
3500 - Local Oversight Program
>
PR0544237
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2019 9:44:55 PM
Creation date
3/6/2019 4:41:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0544237
PE
3528
FACILITY_ID
FA0003765
FACILITY_NAME
AIRPORT SHELL*
STREET_NUMBER
1313
Direction
E
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
15137007
CURRENT_STATUS
02
SITE_LOCATION
1313 E CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
210
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t � <br /> Shell Oil Sites <br /> Page 2 <br /> 1267 Country Club.Stockton <br /> EHD does not consider the extent of the waste oil impac i to soil and groundwater defined. The <br /> work plan.recently submitted has not been approved. An addendum to that work plan will be <br /> prepared that addresses EHD's concerns with the waste c il investigation and provides investigation <br /> down gradient(northeast) of the petroleum fuel contamir.ant plume. <br /> 2575 Coun Club Stockton <br /> The current proposal for replacement of monitoring well NEV5 will not provide the information <br /> required to delineate the extent of the contaminant plume, Additional ground water investigation is <br /> needed in areas where analytical results of soil samples from borings showed the soil to be highly <br /> contaminated. A work plan addendum is to be submitted that proposes placement and construction <br /> of monitoring wells that will provide delineation of the cc ntaminant plume. <br /> 2320 El Dorado Street,Stockton <br /> EHD agreed with Cambria that contaminants might be migrating across El Dorado Street from the <br /> site at 2315 El Dorado Street. It is unknown if the containination detected in the monitoring wells <br /> at the Shell station is the result of the residual soil contarnination from the three UST's that were <br /> removed in 1990 (no further action required letter provided in 1991),a result of new release(s) <br /> between 1991 and the present,or migration of contamina is from the 2315 El Dorado Street site. <br /> EHD requested that an SCM be included in the next qua terly monitoring report(QMR),or by the <br /> 3rd quarter 2005 QMR, that would discuss the contanunZtLt plumes at both sites. <br /> EHD agreed that the enactment of the approved cone penetrometer(CPT)work plan dated October <br /> 4,2004 should be postponed at this time. <br /> Shell agreed to analyze for trichloroethene (TCE) and to achloroethene(PCE)in water samples <br /> from MW-3 and MW-4 the next quarter(3rd QMR) since both contaminants were detected in the 41h <br /> quarter 2004 monitoring event. EHD may request additional quarterly sampling of TCE and PCE iri <br /> two or more monitoring wells in the future. Cambria sugDested that the responsible party of 2315 El <br /> Dorado Street should also include analyses for TCE and PCE on their water samples. EHD <br /> encourages Shell to coordinate sampling and testing with Lhe responsible party for 2315 El Dorado <br /> Street. <br /> As agreed to at the meeting,EHD has completed a cursory review of the history and investigation of <br /> the former waste oil underground storage tank (UST) tan at the 2315 El Dorado Street. In April <br /> 1987,a 200-gallon waste oil UST was removed from the ite. Analytical results of the soil sample <br /> collected beneath the UST were non-detect(ND) for TC and 1.6 micrograms per kilograms <br /> (ug/kg) of PCE. In October 1993 multiple soil samples ere collected from 3 soil borings to.30 feet <br /> below surface grade (bsg) and 1 soil boring to 36 feet bsg that were installed next to the former UST. <br /> Analytical results.of all the samples were ND for PCE an TCE. Analytical results of a ground water <br /> sample from monitoring well MW-1 installed next to the ormer UST in September 1994 were also <br /> ND for PCE and TCE. <br /> EHD also reviewed our Shell station UST file and found hat Shell originally reported a 550 gallon <br /> waste oil UST to be at the site but when EHD staff inspe ted the site in 1986 it was stated that the <br /> UST had been removed prior to 1984 so there is no soil Gata on the Shell waste oil UST. The file <br /> did have soil sample results from the UST system removal in July 1990 and soil samples SS-1,5,7, <br /> 10, 11 and 12 all had detections of PCE in the soil sampl s collected. Please be aware that the <br /> information presented in this letter is based on a cursory review. EHD recommends you perform a <br /> file review of your own. <br />
The URL can be used to link to this page
Your browser does not support the video tag.