My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MELLON
>
800
>
2800 - Aboveground Petroleum Storage Program
>
PR0515468
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/18/2021 8:26:53 AM
Creation date
3/8/2019 8:32:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0515468
PE
2832
FACILITY_ID
FA0003691
FACILITY_NAME
MBM, Manteca
STREET_NUMBER
800
STREET_NAME
MELLON
STREET_TYPE
AVE
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
800 MELLON AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A ` , J O A Q U I LIf1V1, Environmental Health Department <br /> CC)U N <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> MBM, Manteca 800 MELLON AVE, MANTECA March 06, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> r18 <br /> Remarks <br /> CFR 112.7(e), 112.8(c)(6) Failed to keep records of procedures, inspections,or integrity tests for three years. <br /> Copies of inspection and testing records were not found on site. Copies of the monthly and annual inspections <br /> required by the SPCC plan and the STI SP-001 standard were not found. Inspections and tests must be conducted <br /> in accordance with the written procedures developed in the Spill Prevention, Control, and Countermeasure (SPCC) <br /> Plan. Records of these inspections and tests must be signed by the appropriate supervisor or inspector and kept on <br /> site with the SPCC Plan for a period of three years. Immediately locate a copy of all inspection and testing records <br /> for the last three years, maintain them on site, and submit copies to the EHD. <br /> This is a Class II violation. <br /> 7n5 CFR 112.8(c)(1)Container not compatible with oil stored and/or storage conditions. <br /> The SPCC plan did not include a discussion on this section. Containers shall be compatible with the material stored <br /> and the conditions of storage such as pressure and temperature. The SPCC plan should address this section, or <br /> provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> 706 CFR 112.8(c)(2)Failed to provide and maintain adequate secondary containment. <br /> The 55 gallon drums by the outer fence, the 240 gallon used oil tank and the 55 gallon oil drum within the shop area <br /> were observed with insufficient secondary containment. The 55 gallon drums by the outer fence were labeled and <br /> described as storing hydraulic oil,the secondary containment structure was full of liquid and unable to contain the <br /> contents of the largest container. The 240 gallon waste oil tank appeared to be single walled and secondary <br /> containment was not evident. The 55 gallon in the shop area is described in the SPCC plan as having secondary <br /> containment for 10%of the contents. All bulk storage tanks must be provided with a secondary means of <br /> containment for the entire capacity of the tank and sufficient freeboard to contain precipitation. Immediately provide <br /> sufficient secondary containment for this and all other tanks at this facility. <br /> This is a Class II violation. <br /> 711 CFR 112.8(c)(6)Failed to perform scheduled tank tests or inspections by appropriately qualified personnel. <br /> The 10,000 gallon diesel tank was tested by a certified inspector on 4/10/2015. The report could not be found <br /> during the time of the inspection. Each aboveground container shall be tested and inspected for integrity on a <br /> regular schedule and whenever repairs are made. The qualifications of personnel performing tests and inspections, <br /> frequency and type of testing and inspections that take into account container size, configuration, and design shall <br /> be determined in accordance with industry standards. Examples of these integrity tests include, but are not limited <br /> to:visual inspection, hydrostatic testing, radiographic testing, ultrasonic testing, acoustic emissions testing, or other <br /> systems of non-destructive testing. Comparison records and other records of inspections and tests must be <br /> maintained on site. Immediately conduct the necessary testing and submit a copy of the test results to the EHD, or <br /> provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> FA0003691 PR0515468 SCO01 03/06/2019 <br /> EHD 28-01 Rev.09/27/2018 Page 5 of 6 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page