My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MELLON
>
800
>
2800 - Aboveground Petroleum Storage Program
>
PR0515468
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/18/2021 8:26:53 AM
Creation date
3/8/2019 8:32:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0515468
PE
2832
FACILITY_ID
FA0003691
FACILITY_NAME
MBM, Manteca
STREET_NUMBER
800
STREET_NAME
MELLON
STREET_TYPE
AVE
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
800 MELLON AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJOAQUIN Environmental Health Department <br /> —COUNTY— <br /> Aboveground Petroleum Storage Act Compliance Review Report <br /> FacilityNRUB: Facility PlwrM: DM.: <br /> MSM, <br /> SM Manteca 208 823-7157 Dotober 01 2018 <br /> Fadliry AtWrass: LERS ID: <br /> 800 MELLON AVE MANTECA CA 85337 10181315 <br /> Inspedlan canted: rtls: Phon.: <br /> Michael Zimmerman Trans ortation Mana er 209 249-1473 <br /> RR VIOLATIONS <br /> The following non-inspection related violations listed below from the California Health and Safety Code(HSC), California Code of <br /> Regulations(CCR) and/or the Code of Federal Regulations(CFR)were found. <br /> #718 CFR 112.8(c)(11) Failed to locate properly or provide sldficient secondary containment for mobile/portable <br /> containers <br /> OBSERVATIONS:An addendum page submitted through email on 09/20/2019,titled "SPCC addendum 9-20-19.pdf',states <br /> that"the 150 Gallon portable#2 Diesel fuel tank is maintained within the yard and has no secondary containment."This <br /> statement is found on page 17,in the section titled "Discharge Drainage Control 40 CFR 112.7(ax3XIIIy. Previous submitted <br /> versions of the SPCC plan do not address secondary containment of the tank in question. Secondary means of containment <br /> for the entire capacity of the largest single compartment or container and sufficient freeboard to contain precipitation has not <br /> been provided. <br /> The regulation states: <br /> Position or locate mobile or portable oil storage containers to prevent a discharge as described in §112.1(b).Except for <br /> mobile refuelers and other non-transportation-related tank trucks, you must furnish a secondary means of containment,such <br /> as a dike or catchment basin, sufficient to contain the capacity of the largest single compartment or container with sufficient <br /> freeboard to contain precipitation. <br /> Immediately provide sufficient secondary containment for this and all other portable containers at this facility or as allowed by <br /> CFR 112.7.This is considered a technical amendment,lithe plan will be amended,it must be certified by a professional <br /> engineer as required under CFR 112. <br /> This is a Class II violation. <br /> OVERALL NOTES AND COMMENTS <br /> This is an in-office inspection report.This was written after review of the SPCC plan submitted through email on 09/18/2018 <br /> and an addendum received on 09/20/2018 through email.The SPCC plan in question has a registered Professional Engineer <br /> certification from Gary Madsey,registration number 70508, on 07/15/2018. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement documenting the <br /> corrective actions that have been or will be taken for each violation,and any supporting paperwork,within 30 days of receiving <br /> this report. <br /> Starting September 1,2018,all in-office CERS help will be provided at EHD hourly rate($152). To schedule an appointment, <br /> please call(209)468-3420. <br /> 11L-1 STAFF TME ASSOMATEG 1M H FNNNG TG COMPLY BY THEABW E NGTEG GATES wLL BE BILLEG AT THE CURRENT HOURLY RATE <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EH D'S CURRENT HOURLY RATE. <br /> Please submit all requested documentation to the address below,attention to: CESAR RUVALCABA, REHS. <br /> If you have any questions, please contact CESAR RUVALCABA at(209)953-6213. <br /> FAOOOAS1 PR0515,168 SN21 IMIM19 <br /> Rev.04H 112019 Page1 M1 Abavegrwnd Ptlrtlam SWr AC Canglmm Re—Rgrrt <br /> 1868 E.Hazelton Avenue I Stockton,California 952051 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.