Laserfiche WebLink
PO Box 1928 STI SP-001 <br /> POWERS BENICIA,CA <br /> TEL 707707 333343400 STOCKTON EAST WATER DISTRICT STOCKTON,CA <br /> FAx 707 922 2284 <br /> ENGINEERING$INSPECTION,INC. www.powerseixom Tank 19 <br /> 2.2 Monthly Inspection Checklist <br /> General Inspection Information <br /> 1. Inspection Date: 11/30/2018 <br /> 2. Retain Until Date(36 months from inspection date): 11/30/2021 <br /> 3. Prior Inspection Date: - <br /> 4. Inspector(s)Name(s): Jay Sheely <br /> 5. Tanks Inspected (ID#'s): Tank 19 <br /> 1.0 Tank Containment Status Comment <br /> 1.1 Water in primary tank, secondary containment, No <br /> interstice, ors ill container? <br /> 1.2 Debris or fire hazard in containment? No <br /> 1.3 Drain valves operable and in a closed position? N/A <br /> 1.4 <br /> Containment egress pathways clear and gates/doors <br /> operable? <br /> Yes <br /> 2.0 Leak Detection Status Comment <br /> 2.1 <br /> Visible signs of leakage around the tank, concrete pad, Minor seepage on threaded <br /> containment, ring-wall or ground? Yes components <br /> Is the leak detector in good condition (Check tube cap <br /> for corrosion and proper operation)? If a Kruger <br /> manual leak indicator is installed, remove the red ring <br /> 2.2 <br /> and clear cap and check to see that the red indicator he interstice was not equipped <br /> moves up and down about 1 inch freely. Also, check NO with a leak detector. <br /> for weathering or cracks in the clear cap. If electronic <br /> leak detection is installed, check it by using the test <br /> button)? <br /> 3.0 Tank Attachment and Appurtenances Status Comment <br /> 3.1 <br /> Ladder and platform structure secure with no sign of N/A <br /> severe corrosion or damage? <br /> 3.2 <br /> Tank Liquid Level Gauge readable and in good <br /> condition? Yes <br /> 3.3 Are all tank openings properly sealed? Yes <br /> 3.4 <br /> Are all nozzles, hoses and fittings in good condition (no Coating failure and minor corrosion <br /> wear and tear)? Yes present <br /> 3.5 <br /> Are trigger mechanism on nozzle in good condition (no <br /> metal fatigue or mechanical failure)? <br /> Yes <br /> 4.0 Other Conditions Status Comment <br /> The fire extinguisher is located <br /> Are there other conditions that should be addressed for within 1-ft of the tank and should <br /> 4.1 continued safe operation or that may affect the site Yes <br /> SPCC plan? moved to a location 15-ft away <br /> from the tank incase of fire. <br /> Is the pump motor in good condition (no signs of over- <br /> 4.2 heatingor excessive wear)? <br /> Yes <br /> STI-SP001 Stockton Water District Tk 19 Stockton,CA 2019 Rev O..docx Date Printed:2/4/19 <br /> ©2018 PE&I Inc. <br /> Page 10 <br />