Laserfiche WebLink
SAN 10 A Q U I N Environmental Health Department <br /> COUNTY <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> RIGHETTI ENTERPRISES 1 1634 E CHANNEL ST, STOCKTON March 08, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 66262.34(d)(2) No modified contingency plan. <br /> An emergency coordinator and modified contingency plan information is lacking. There must be at least one <br /> emergency coordinator on site or on call to coordinate emergency response measures, and the following <br /> information must be posted by a phone:the name and phone number of the emergency coordinator; location of fire <br /> extinguishers, spill control equipment, and if present,fire alarm; and the phone number of the fire department, <br /> unless the facility has a direct alarm. Immediately appoint an emergency coordinator and post the required <br /> information by a phone. A form is provided that can be used for this purpose. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 406 CCR 66261.7 Contaminated container not marked with date emptied or managed within one year of being emptied. <br /> There were six empty 55 gallon waste drums that were not labeled empty. <br /> Containers larger than five gallons that previously held a hazardous material shall be marked with the date they <br /> were emptied and managed within one year of being emptied. Immediately mark and manage all empty containers <br /> per this section. <br /> Corrected on site. <br /> This is a repeat violation, Class ll. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by April 8, 2019. <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an <br /> appointment, please call (209)468-3420. <br /> Waste streams observed: <br /> - used oil (Taken by American Valley Oil) <br /> -drained used antifreeze (Taken by American Valley Oil) <br /> - use lead acid batteries (Returned to Seller Diesel Performance) <br /> Inspector provided: Return to Compliance Certification form, Schedule of free CUPA Classes, Example <br /> hazardous waste labeling information. <br /> FA0010852 PRO514439 SCO01 03/08/2019 <br /> EHD 22-01 Rev.09/27/2018 Page 4 of 5 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />