Laserfiche WebLink
�...Q .. C San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br /> • �..• _ P• Telephone: (209)468-3420 Fax:(209)464-0138 Web:www.s'gov.org/ehd <br /> 4�IFO'Rt� <br /> Food Program Official Inspection Report <br /> Facility Name and Address: NENAS DELIGHTS& BBQ,445 W WEBER AVE, STOCKTON 95203 <br /> #38 Approved/Sufficient Ventilation and Lighting <br /> OBSERVATIONS:Several light(3)burned out. replace by 1 week. <br /> CALCODE DESCRIPTION:Exhaust hoods shall be provided to remove toxic gases,heat,grease, vapors and smoke and be approved by <br /> the local building department. Canopy-type hoods shall extend 6"beyond all cooking equipment.All areas shall have sufficient ventilation <br /> to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window,an air shaft, or a <br /> light-switch activated exhaust fan,consistent with local building codes. (114149, 114149.1)Adequate lighting shall be provided in all areas <br /> to facilitate cleaning and inspection.Light fixtures in areas where open food is stored,served,prepared,and where utensils are washed <br /> shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1) <br /> #39 Thermometers Provided/Accurate/Easily Visible <br /> OBSERVATIONS:Refrigerators at front area lack thermometers. Provide by 1 week. <br /> CALCODE DESCRIPTION:An accurate easily readable metal probe thermometer suitable for measuring temperature of food shall be <br /> available to the food handler. A thermometer+/-2#F shall be provided for each hot and cold holding unit of potentially hazardous foods <br /> and high temperature warewashing machines. (114157, 114159) <br /> #41 Plumbing Maintained;Approved Back Flow Device <br /> OBSERVATIONS:Floor sink servicing soda fountain and hand sink drains very slow. Unplug, immediately. <br /> Waste line servicing hand sink is loose. Repair, immediately. <br /> Waste line for ice maker and soda fountain drop into floor sinks. Raise at least one inch above rim of sinks. Correct by 1 <br /> week. <br /> CALCODE DESCRIPTION:The potable water supply shall be protected with a backflow or back siphonage protection device,as required <br /> by applicable plumbing codes. (114192)All plumbing and plumbing fixtures shall be installed in compliance with local plumbing <br /> ordinances,shall be maintained so as to prevent any contamination,and shall be kept clean,fully operative,and in good repair. Any hose <br /> used for conveying potable water shall be of approved materials,labeled,properly stored,and used for no other purpose. (114171, <br /> 114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269) <br /> #43 Toilet Facilites Clean/Supplied/Maintained <br /> OBSERVATIONS:Toilet paper is not inside dispenser. Provide paper for dispenser on wall at all times. <br /> CALCODE DESCRIPTION:Toilet facilities shall be maintained clean, sanitary and in good repair. Toilet rooms shall be separated by a <br /> well-fitting self-closing door. Toilet tissue shall be provided in a permanently installed dispenser at each toilet. The number of toilet <br /> facilities shall be in accordance with local building and plumbing ordinances. Toilet facilities shall be provided for patrons:in <br /> establishments with more than 20,000 sq ft. establishments offering on-site liquor consumption. (114250, 114250.1, 114276) <br /> FA0012081 PRO515288 SCO01 09/19/2016 <br /> EHD 16-23 Rev.06/30/15 Page 2 of 3 Food Program OIR <br />