Laserfiche WebLink
PACIFIC ENVIRONMENTAL SYSTEMS LLC <br /> Periodic Integrity Test Certificate <br /> P.O. Box 576231. Modesto, CA 95357 Telephone: (209) 549-2451/209-499-6692ceB <br /> Email: aacificenv_ rn3 ',dem <br /> -------------------------------------------------------------------------------------------------------------- <br /> C6ent: Tiger Lines,LLC Contact : Mark Handel, Environmental Compliance Mer. <br /> Address: 927 Black Diamond Way Phone No.: 800-967-8443 <br /> City/State/Zip; Lodi, CA 95240 Date of Test: 4-25-2019 <br /> Product Stored: Diesel Fuel Tank A <br /> Tank Information(Brand/gallonage/Fuel Stored/UL or otter serial#/miscellaneous) <br /> Modern Weldinw25000 gals/Diesel Fuel/1UTL2085/tJL#A702552/Doub1e Wall Steel/22 vrs oldQ/1995 1 <br /> Description of Secondary Containment Integral Secondary Containment <br /> Date of Test-4-25-2014 Test Supervisor(s), Todd McWhorter <br /> METHOD OF PERIODIC INTEGRITY TEST-Primary XX Secondary XX <br /> ]. Steel Thickness Test(in accordance with API-653 and/or STI SP001 (6" edition)-Readings Steel <br /> Thickness UL142 min. .240in./Avg Steel thickness=332 in,as tested <br /> 2. Inert Gas Blanket <br /> Gas Used: Nitrogen_; CO2:_: Other(specify) _ <br /> Air Pressure-Test Vacuum Test <br /> Initial Reading (document psi/WC readings) 511g Time 8:00am <br /> End Readings (document psi/WC readings) 5112 Time 9:00am <br /> Duration of Test %drop <br /> 3. Sonar-Test_Y N (document db readings) Duration <br /> 4. Camera(visual)model Lorex MC81845/interstitial __(Result: P/F)_ +_> <br /> 5. Hydro-Carbon Sensor (probe) model OMNTEC BOA- (Result:P/F) <br /> 6. Hydrology (Water Column) (inches of water cotunut readings) <br /> Duration %Drop Results (P/P) <br /> 7. Other: Inspect Vessel&secondary containment. AST clearance is 5 inches above floor. CRDM <br /> present, Tank is Category 1 under STI-SP001 Standards. No evidence of leaking product from <br /> rimary vessels stem accessible for inspection: No product in seeondarv.Upon inspection.no evidence <br /> of weld breaks unctures cracks or other structural damage to the tank. No external issues affectin tank <br /> integrity. AST is anchored to concrete floor. :PASS <br /> TEST RESULTS <br /> I"-Stage: <br /> Pass XX Fail_(quantify) SENSOR DETECTS NO PRODUCT NOR LEAKS FROM PRIMARY <br /> TANK INTO SECONDARY CONTAINMENT <br /> 2° -Stage: <br /> Pass XX Fail_(quantify) NO VISUAL EVIDENCE OF PRODUCT IN THE SECONDARY <br /> NOR OF ANY OTHER LEAKS & STEEL THICKNESS IN EXCESS OF MINIMUM UNDER UL <br /> 142 STANDARD & NO DECAY ON VACUUM LEVELS FOR VACUUM TEST FOR 1 HR. <br /> Comments section data on file <br /> Next Scheduled Periodic Integrity Test 4-25-2039 <br /> � ^ <br /> Pacific Environmental Symms,Representative <br /> STI SP001 Certified Inspector No.: AST 135013 <br />