My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
401
>
2300 - Underground Storage Tank Program
>
PR0231346
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2022 10:36:02 AM
Creation date
3/20/2019 11:10:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231346
PE
2361
FACILITY_ID
FA0003603
FACILITY_NAME
TESORO (SPEEDWAY XP) 68152
STREET_NUMBER
401
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04513019
CURRENT_STATUS
01
SITE_LOCATION
401 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
140
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RIN <br />tc,`lPEi/RP1200-17 <br />sump, where it can be easily observed or detected <br />by a sensor. <br />This section describes a hydrostatic test method. <br />There are vacuum test methods available for con- <br />tainment sumps. Consult the manufacturer before <br />performing a vacuum test. <br />NOTE: Follow the manufacturer's instructions <br />when testing the interstitial spaces of double - <br />walled containment sumps. <br />6.5.2 Purpose. This section describes the prepa- <br />ration and procedures to test the integrity of con- <br />tainment sumps to ensure that they do not leak. <br />6.5.3 Description of Test. The containment <br />sump is filled to the proper level with water. The <br />water level is measured at the beginning and end of <br />the test. <br />6.5.4 Test Equipment. Test equipment shall <br />include: <br />• water; <br />• measuring stick that is accurate to within 1/16 <br />(0.063) inch and of sufficient length; <br />stopwatch or other time -measurement device <br />capable of measuring a 1 -second increment. <br />6.5.5 Preparation. <br />1. Care should be taken when conducting the test <br />in the rain or during freezing weather condi- <br />tions. <br />2. Remove and properly dispose of any liquid and <br />debris (leaves, sediment and trash) in the con- <br />tainment sump. <br />3. Inspect the containment sump for damage. <br />Examine all penetration fittings, conduits, junc- <br />tion boxes, caps and risers (if present), and side- <br />wall seams for defects, damage or improperly <br />installed components. If there are loose com- <br />ponents (e.g., loose penetration fitting clamps <br />or missing interstitial space caps), correct these <br />items before performing the integrity test. If <br />there are items that must be repaired or replaced <br />(e.g., deteriorated penetration fitting boots), <br />notify the owner/operator and obtain approval <br />prior to proceeding with repairs. <br />4. Test boots or secondary containment termina- <br />tion fittings must be present on the piping pen- <br />etrating the sump. During testing, these fittings <br />0 peLorg <br />prevent water from entering the interstitial space <br />of double -walled piping. Without these fittings, <br />the integrity of the sump cannot be tested using <br />this method. <br />S. If interstitial monitoring sensors are present <br />within the containment sumps, temporarily <br />remove them before conducting the test. If the <br />sensor is removed, reposition after testing to <br />appropriate position according to the manufac- <br />turer's instructions. <br />6. If the containment sump is found to have cracks, <br />loose parts or separation of any joints or penetra- <br />tion fittings, it is not considered to be liquid - <br />tight. This visually indicates a test failure. <br />CAUTION: Water can damage electrical <br />connections. Ensure that there are no <br />components that can be damaged by the <br />addition of water to the sump. If such <br />components are present, take appropriate <br />precautions when performing the test or <br />use an alternative test method. <br />Water Electrical <br />Level Junction <br />1 Box <br />Eiectdcal <br />ConduR <br />Product <br />IL Piping <br />FIGURE 6-5. The test fluid level in the under dispenser <br />containment (UDC) must be at least 4 inches above the <br />highest sump penetration or sidewall seam. <br />6.5.6 Test Procedure. <br />1. Begin the test by adding water to the sump to a <br />minimum of 4 inches above the highest sump <br />penetration or sump sidewall seam, whichever is <br />higher. To compensate for sump deflection, the <br />water must be allowed to settle a minimum of <br />15 minutes before taking the initial test measure- <br />ment. If the highest sump penetration or sump <br />sidewall seam is less than 4 inches from the top <br />
The URL can be used to link to this page
Your browser does not support the video tag.