Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1 ) <br /> Type of Action ❑ Installation Inspection ❑ Repair Inspection Z 36 Month Inspection <br /> 1 . FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10180975 6/ 19/2019 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> TOSCO 08671 Stockton 76 <br /> Business Site Address City ZIP Code <br /> 8606 Thornton Stockton 95209 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) Phone # <br /> Garrett Warren <br /> Contractor I Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> CSLB#803616 8185019 10/2/2019 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br /> Veeder- Root 842126 exp . 1 -21 -21 OPW EVR 101018 exp . 6-5-21 <br /> III . OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ❑ Manufacturer Guidelines (Specify) : <br /> Used : <br /> N Industry Code or Engineering Standard (Specify) : RP1200 <br /> ❑ Engineered Method (Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages <br /> TANK ID : (By tank number, stored product, etc.) T1 : 91 T2 : 89 T3 : 87 <br /> What is the tank inside diameter? (Inches) 91 If 91 if 91 <br /> if <br /> Is the fill piping secondarily contained? ❑x Yes ❑ No I] Yes ❑ No Z Yes ❑ No ❑ Yes ❑ No <br /> Is the vent piping secondarily contained ? H Yes ❑ No El Yes ❑ No Z Yes ❑ No ❑ Yes ❑ No <br /> Overfill Prevention Equipment Manufacturer(s) oPW oPW oPW <br /> What is the overfill prevention equipment response ❑x Shuts Off Flow ❑x Shuts Off Flow ❑x Shuts Off Flow ❑ Shuts Off Flow <br /> when activated ? ❑x Restricts Flow ❑x Restricts Flow N Restricts Flow ❑ Restricts Flow <br /> (Check all that apply.) <br /> ❑ AIV Alarm R A/V Alarm ❑ AIV Alarm ❑ A/V Alarm <br /> Are flow restrictors installed on vent piping ? ❑ Yes E No ❑ Yes E No ❑ Yes Rx No ❑ Yes ❑ No <br /> At what level in the tank is the overfill prevention set <br /> to activate? (Inches from bottom of tank.) 828282If <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 90 % 90 % 90 % <br /> Is the overfill prevention in proper operating condition ❑x YesYes Z Yes El Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑ No (Specify in V.) ❑ No (Specify in V.) ❑ No (Specify in V.) ❑ No (Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ❑x Pass ❑ Fail I Z Pass ❑ Fail ❑x Pass ❑ Fail ❑ Pass ❑ Fail <br /> V. COMMENTS <br /> Any items marked "Fail" must be explained in this section. Any additional comments may also be provided here. <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipmentwas inspected in accordance with California Code of Regulations , Title 23 , <br /> Division 3 , Chapter 16 , Section 2637.2 and all the information contained herein is accurate . <br /> UST Service Technician Signature <br /> If the facility has mor components than this form accommodates, additional copies of this page maybe attached. <br /> CERS = Califomia Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = International Code Council, AN = Audible and Visual <br />