My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
130
>
2300 - Underground Storage Tank Program
>
PR0231861
>
COMPLIANCE INFO 2008 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2019 4:32:18 PM
Creation date
3/20/2019 3:57:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2015
RECORD_ID
PR0231861
PE
2361
FACILITY_ID
FA0003601
FACILITY_NAME
ARCO STATION #826951*
STREET_NUMBER
130
Direction
S
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205-5561
APN
15502064
CURRENT_STATUS
01
SITE_LOCATION
130 S WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
248
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY RECEIVED <br /> ENVIRONMENTAL HEALTH DEPARTMENT FEg 0 6 2014. <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www slgov org"V1R0NMENTAL <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPOR7"EPARTMENT <br /> Facility Facility <br /> Name: Arco AM/PM Address: 130 S. Wilson, Stockton Inspection Jan 24, 2014 <br /> Facility Title: <br /> Contact: Parmjit Singh Owner 4e6633 <br /> Inspection <br /> Type: X Routine X Monitoring System Certification 1.1 Installation Complaint-ID#: Other: <br /> (Authority HSC 25289) <br /> Consentfor: XInspection -,Sampling XPhotos Granted by:Parmjit Singh Owner <br /> Title: <br /> Monitoring Piping Overfill <br /> Panel: Veeder-Root TLS-350 System: XPressurized L.Suction Gravity Prevention: Mechanical XAudible/visual <br /> -- UST---- ------1------ - - - 3 <br /> Product 87-octane 87-slave - - - 91 - ----------------- ------------- -------------- ----- - - --- ----------- ------------ <br /> Designated ICC Exp. <br /> Operator: James Will IamS5252274 Date: 6/4/15 Violations: C M1-Release Detection I M2-Release Prevention J M3-Both <br /> On Site Service ICC Exp. Manufacturer's <br /> Technician: FeIIXRamirez5273934 Date: 12/6/14 Training: VM12516 11/12/15; VR B34976 6/25/14 <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=California Health and Safety Code;CCR=California Code of Regulations <br /> Cl Class 1 violation C2=Class 2 violation,M=Minor violation <br /> Ws.s,;.....- <br /> 101 <br /> HSC 25284 No permit to operate <br /> 102 HSC 25404.5 1 Annual operating fees not paid <br /> 103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br /> monitor the tanks stem <br /> 104 X HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department(EHD) <br /> 105 CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 106 CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br /> 108 CCR 2637 Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(f)test notification <br /> not rovided to the EHD at least 48 hours prior to conducting the test <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 days; <br /> 109 CCR 2638 (e)test notification not provided to the EHD at least 48 hours prior to conducting an installation, repair, <br /> replacement,calibration,or certification <br /> 110 HSC 25291(f) Annual line leak detector test not performed (M1) <br /> 111 HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (M1) <br /> 113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> 115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br /> ermit conditions <br /> 116 HSC 25292.5 Enhanced leak detection(ELD)testing not performed on a system located within 1000'of public well,or <br /> failures not—aired and retested <br /> 117 CCR 2661 Permit to repair UST system not obtained <br /> 118 HSC 25286(a) O <br /> 19 HSC 25298(b) perational permit not amended when UST storage and/or monitoring system changed <br /> 1Permit to temporarily close UST system not obtained <br /> 120 HSC 25298(c) Permit to close UST system not obtained <br /> OnStteRecords res r <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6'/2 years,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 201 CCR 2712(b) upgrades for the life of the tank. Monitoring records include: (1)date and time of all monitoring or sampling; <br /> (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations; (4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring <br /> equipment, round water elevations,or other test results; (6)results of inventory readings and reconciliations <br /> 202 CCR 2712(i) Monitoring plan, response plan,and/oro operating g permit and all conditions not onsite <br /> Unauthorized release that: (c)did not escape secondary containment and cleaned up within eight hours (M1) <br /> 203 CCR 2650 was not recorded;(e)escaped secondary containment, not cleaned up after eight hours,or a sudden loss of <br /> product was not reported to the EHD within 24 hours <br /> Inspector Received By: <br /> Jeffrey Won Title: <br /> Wong (209) 468-0335 <br /> =HD 23-02 Rev 04/19/12 <br /> Page 1 <br /> 1 ICT Inicorrrinni oar,.-.ter <br />