My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
130
>
2300 - Underground Storage Tank Program
>
PR0231861
>
COMPLIANCE INFO 2008 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2019 4:32:18 PM
Creation date
3/20/2019 3:57:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2015
RECORD_ID
PR0231861
PE
2361
FACILITY_ID
FA0003601
FACILITY_NAME
ARCO STATION #826951*
STREET_NUMBER
130
Direction
S
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205-5561
APN
15502064
CURRENT_STATUS
01
SITE_LOCATION
130 S WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
248
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
02/10/2009 19:23 2094654988 HMC PAGE 02/02 <br />..mow <br />i <br />1.41 min ,,,s W-oter Issuca Programs list Leak Prevention ..r Lg113 ---N Vendors <br />Programs - LG .11.3 <br />Isseie Dato: November 22, 1995 <br />Revirion Date May 15, Won$ <br />Veeder-Root <br />TLS 350, <br />350PC, 350R, 350RPC, 350PIus, 450, Red Jacket ProMax Leak Detector, Series 8484 <br />AUTOMATIC ELECTRONIC LINE LEAK DETECTOR <br />G'artification <br />Leak rate of 3.0 gph at 10 psi' with PD = 100% and PFA = 0"/0. <br />Leak rate of 0.2 gph at operating pressure with PC = 100% and PFA = 0%. <br />Leak rate of 0.1 gph at 1.5 times operating pressure* with PD � 100% and PFA = 0%. <br />-Since leak rate varies as a function of pressure, this leak rate and pressure were certified using an <br />equivalent leak rate and pressure, in accordance with an acceptable protocol. <br />Litak Threshold <br />1.88 gph for leak rate of 3.0 gph. <br />0.17 gph for leak rate of 0.2 gph. <br />0.05 gph for leak rate of 0.1 gph. <br />A pipeline system should not be declared tight if the test result indicates a loss that equals or exceeds this <br />threshold. <br />Applicability <br />Gasoline, diesel, aviation fuel. <br />Other liquids may be tested after consultation with the manufacturer, <br />Specification <br />System tests pressurized fiberglass and steel pipelines. <br />Tests are conducted at operating pressure. <br />System will not function with a mechanical line leak detector installed in the pipeline. <br />Fjpeline Capacity <br />Maximum of 98.4 gallons. <br />df 1f ling Timo <br />None between delivery and testing. <br />Minimum of 16 minutes between dispensing and testing for leak rate of 3.0 gph. <br />Minimum of 45 minutes to 1 hour between dispensing and testing for leak rate of 0.2 gph. <br />Minimum of 2 hours, 30 minutes between dispensing and testing for leak rate of 0.1 gph. <br />Tast period <br />Response time Is 28.8 seconds for leak rate of 3.0 gph. <br />Response time is 32 to 48 minutes for leak rate of 0.2 gph. <br />Response time is 18 minutes for leak rate of 0.1 gph. <br />Test data are acquired and recorded by a microprocessor. <br />Calculations are automatically performed by the microprocessor. <br />Slystem Features <br />Permanent installation on pipeline. <br />Automatic testing of pipeline. <br />Preset threshold, <br />Single test to determine if pipeline is leaking. <br />Pump shutdown (optional), message display and a;arm activation if leak is declared. <br />Calibration <br />Equipment must be checked annually for capability of detecting a line leak of 3.0 gph and, if <br />necessary, calibrated in accordance with manufacturer's instructions. <br />Weder-Root <br />125 Powder Forest Dr. <br />SiMsbury, CT 060702003 <br />Tel: (860)651-2700 <br />E-mail; dhaliain3vecdei com <br />URL; nrrew,veecler.cam/dvnarr�iclirinex cin <br />Evaluator: Midwest Research Institute <br />Tel: (815) 753-7600 <br />Date of Evaluation: 08/07/91, 12/18/96 <br />Evaluator. Ken Wilcox Associates <br />Tel: (816) 443.2494 <br />Dates of Evaluation: 2127/2008 <br />x <br />� 4•#nnta I Vendors: A- F I VE.ttdor.,. G M S Vendors: Ed S I Vendors: T -Z I MethodInde � <br />
The URL can be used to link to this page
Your browser does not support the video tag.