My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
130
>
2300 - Underground Storage Tank Program
>
PR0231861
>
COMPLIANCE INFO 2008 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2019 4:32:18 PM
Creation date
3/20/2019 3:57:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2015
RECORD_ID
PR0231861
PE
2361
FACILITY_ID
FA0003601
FACILITY_NAME
ARCO STATION #826951*
STREET_NUMBER
130
Direction
S
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205-5561
APN
15502064
CURRENT_STATUS
01
SITE_LOCATION
130 S WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
248
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FCEIVED <br /> SWRCB,January 2002 JUN 19 2014 Page of <br /> 9. FILL RISER CONTAINMENT SUMP <br /> Facility is Not Equipped With Fill Riser Containment Sumps L <br /> Fill Riser Containment Sumps are Present,but were Not Tested <br /> Test Method Developed By: ❑Sump Manufacturer E Industry Standard X Professional Engineer <br /> L Other(Spec) <br /> Test Method Used: ❑Pressure Vacuum X Hydrostatic <br /> Li Other(Specify) <br /> Test Equipment Used: Caldwell Level Change Indicator Equipment Resolution: .002 <br /> Fill Sump# 1-87-M Fill Sump#2-87-5 Fill Sump#3-91 Fill Sump# <br /> Sump Diameter: 42" 42" 42" <br /> Sump Depth: 46" 53" 48" <br /> Height from Tank Top to Top of 22" 23" 22" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 20" 24" 20" <br /> Electrical Penetration: <br /> Condition of sump prior to Dry Dry Dry <br /> testing: <br /> Portion of Sump Tested Water Level 24 %2" Water Level 26" Water Level 24" <br /> Sump Material: Fiberglass Fiberglass Fiberglass <br /> Wait time between applying 5 Minutes 5 Minutes 5 Minutes <br /> water and starting test: <br /> Test Start Time: 8:35 9:25 10:25 <br /> Initial Reading(111): .001 .001 .001 <br /> Test End Time: 9:05 9:55 10:55 <br /> Final Reading(RF): .001 .001 .001 <br /> Test Duration: 30 Minutes 30 Minutes 30 Minutes <br /> Change in Reading(RF-R,): 0 0 0 <br /> Pass/Fail Threshold or Criteria: .005/30 Minutes .005/30 Minutes .005/30 Minutes <br /> Test Result: Pass Pass Pass <br /> Is there a sensor in the sump? Yes Yes Yes <br /> Does the sensor alarm when <br /> either product or water is Yes Yes Yes <br /> detected? <br /> Was sensor removed for testing? Yes Yes Yes <br /> Was sensor properly replaced and Yes Yes Yes <br /> verified functional after testin ? <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.