Laserfiche WebLink
M221/2011 :6:31 1209) 465-4988 HNIC - Henderson Nlaint Co Page 15 <br />LIQUID SENSOR SETUP <br />L 1:87 MASTER ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 2:87 MASTER TURBINE <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 3:67 SLAVE ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 4:87 SLAVE TURBINE <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 5:91 ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 6:91 TURBINE <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 7:DISP 1-2 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L 9:DISP 3-4 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L 9:DISP 5-6 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L10:DISP 7-8 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L11:VENT SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : PIPING SUMP <br />L15:87 MASTER FILL <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : PIPING SUMP <br />1,16:87 SLAVE FILL SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : PIPING SUMP <br />L17:91 FILL SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : PIPING SUMP <br />OUTPUT RELAY SETUP <br />R 1:87 SLAVE VSFC <br />TYPE: <br />PUMP CONTROL OUTPUT <br />TANK #: 1 <br />LIQUID SENSOR ALMS <br />L 2:FUEL. ALARM <br />L 4: FUEL ALARM <br />L 7:FUEL ALARM <br />L N:FUEL ALARM <br />L 9:FUEL ALARM <br />L10:FUEL ALARM <br />L 2:SENSOR OUT ALARM <br />L 4:SENSOR OUT ALARM <br />L 7:SENSOR OUT ALARM <br />L 9:SENSOR OUT ALARM <br />L 9:SENSOR OUT ALARM <br />L1D:SENSOR OUT ALARM <br />L 2:SHORT ALARM <br />L 4:SHORT ALARM <br />L 7:SHORT ALARM <br />L 8:SHORT ALARM <br />L 9:SHOR'T ALARM <br />L10:SHORT ALARM <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD SETUP FAIL <br />ISD SENSOR OUT FAIL <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />R 2:0VERFILL ALARM <br />'TYPE <br />STANDARD <br />NORMALLY OPEN <br />TANK #: NONE <br />IN -TANK ALARMS <br />ALL:OVERFILL ALARM <br />ALL:HIGH PRODUCT ALARM <br />ALL:MAX PRODUCT ALARM <br />YLL~L'"I NE -DI SABLE SETUP <br />Q 1 :91 <br />LIQUID SENSOR ALMS <br />L b:FU£L ALARM <br />L 7:FUEL ALARM <br />L 8:FUEL ALARM <br />L 9:FUEL ALARM <br />L10:FUEL ALARM <br />L 6:SENSOR OUT ALARM <br />L 7:SENSOR OUT ALARM <br />L 8:SENSOR OUT ALARM <br />L 9:SENSOR OUT ALARM <br />L10:SENSOR OUT ALARM <br />L 6:SHORT ALARM <br />L ?:SHORT ALARM <br />L S:SHORT ALARM <br />L 9:SHORT ALARM <br />L10:SHORT ALARM <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD SETUP FAIL <br />ISD SENSOR OUT FAIL <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />Q 2:87 <br />LIQUID SENSOR ALMS <br />L 2:FUEL ALARM <br />L 4:FUEL ALARM <br />L 7:FUEL ALARM <br />L 8:FUEL ALARM <br />L 9:FUEL ALARM <br />L10:FUEL ALARM <br />L 2:SENSOR OUT ALARM <br />L 4:SENSOR OUT ALARM <br />L 7:SENSOR OUT ALARM <br />L 8:SENSOR OUT ALARM <br />L 9:SENSOR OUT ALARM <br />L1D:SENSOR OUT ALARM <br />L 2:SHORT ALARM <br />L 4:SHORT ALARM <br />L 7:SHORT ALARM <br />L 3:SHORT ALARM <br />L 9:SHORT ALARM <br />L10:SHORT ALARM <br />ISD SITE ALARMS <br />ISD GROSS FRES FAIL <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD SETUP FAIL <br />ISD SENSOR OUT FAIL <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />